Design and testing of a 1.5 Tesla double-tuned (1H/31P) RF surface coil with intrinsic geometric isolation

被引:11
|
作者
Alfonsetti, Maria [1 ]
Sotgiu, Antonello [1 ]
Alecci, Marcello [1 ]
机构
[1] Univ Aquila, Dipartimento Sci Salute, I-67100 Laquila, Italy
关键词
NMR; MRI; MRS; Radio frequency; Surface coil; Double-tuned; P-31; SPECTROSCOPY; IN-VIVO; H-1; PROBE; MRI;
D O I
10.1016/j.measurement.2010.07.003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We analyse the isolation characteristics of axial and transverse field surface radio frequency coils, used to design a double-tuned surface coil composed by two coils, that combine proton (H-1) detection and localized spectra of phosphorous (P-31). Several geometrical configurations were analysed, including circular loop and figure-of-eight coils, with the aim to optimize the isolation between the two channels. Our analysis shows that by using at least one transverse coil for the design of the double-tuned probe, it is possible to achieve a good intrinsic geometrical decoupling, without the need of additional decoupling circuits. On the basis of the experimental results, we have designed and built a 1.5 T double-tuned probe composed by a circular loop coil and a transverse field coil, with the external coil tuned at the frequency and the internal coil tuned at the P-31 frequency, that shows a good intrinsic decoupling and signal-to-noise ratio. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1266 / 1276
页数:11
相关论文
共 50 条
  • [31] Numerical Simulation and Evaluation of a Four-Channel-by-Four-Channel Double-Nuclear RF Coil for 1H MRI and 31P MRSI at 7 T
    Du, Feng
    Liu, Shengping
    Chen, Qiaoyan
    Li, Nan
    Dou, Yan
    Yang, Xing
    Wang, Zhe
    Zhang, Xiaoliang
    Shen, Baozhong
    Li, Ye
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (11)
  • [32] Numerical and Workbench Design of 2.35 T Double-Tuned (1H/23Na) Nested RF Birdcage Coils Suitable for Animal Size MRI
    Fantasia, Marco
    Galante, Angelo
    Maggiorelli, Francesca
    Retico, Alessandra
    Fontana, Nunzia
    Monorchio, Agostino
    Alecci, Marcello
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3175 - 3186
  • [33] Monitoring Response of Liver Cancer to Targeted Radiation Therapy with a Novel 31P/1H MRS Coil
    Panda, A.
    Jones, S.
    Sandrasegaran, K.
    Dydak, U.
    MEDICAL PHYSICS, 2010, 37 (06) : 3470 - +
  • [34] 1H/31P Polarization Transfer at 9.4 Tesla for Improved Specificity of Detecting Phosphomonoesters and Phosphodiesters in Breast Tumor Models
    Wijnen, Jannie P.
    Jiang, Lu
    Greenwood, Tiffany R.
    van der Kemp, Wybe J. M.
    Klomp, Dennis W. J.
    Glunde, Kristine
    PLOS ONE, 2014, 9 (07):
  • [35] Double-Tuned Surface 1H–23Na Radio Frequency Coils at 7 T: Comparison of Three Decoupling Methods
    Francesca Maggiorelli
    Eddy B. Boskamp
    Gianluigi Tiberi
    Alessandra Retico
    Mark R. Symms
    Michela Tosetti
    Fraser Robb
    Applied Magnetic Resonance, 2019, 50 : 649 - 661
  • [36] Design of a Quadrature 1H/31P Coil Using Bent Dipole Antenna and Four-Channel Loop at 3T MRI
    Hong, Suk-Min
    Choi, Chang-Hoon
    Magill, Arthur W.
    Shah, N. Jon
    Felder, Joerg
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (12) : 2613 - 2618
  • [37] 9.4 T double-tuned 13C/1H human head array using a combination of surface loops and dipole antennas
    Avdievich, Nikolai I.
    Solomakha, Georgiy
    Ruhm, Loreen
    Henning, Anke
    Scheffler, Klaus
    NMR IN BIOMEDICINE, 2021, 34 (10)
  • [38] Dynamic interleaved 1H/31P STEAM MRS at 3 Tesla using a pneumatic force-controlled plantar flexion exercise rig
    M. Meyerspeer
    M. Krššák
    G. J. Kemp
    M. Roden
    E. Moser
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 257 - 262
  • [39] Transmit-receive coil-arrays at 17.6T, configurations for 1H, 23Na, and 31P MRI
    Gareis, D
    Neuberger, T
    Behr, VC
    Jakob, PM
    Faber, C
    Griswold, MA
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2006, 29B (01) : 20 - 27
  • [40] Design and test of a double-nuclear RF coil for 1H MRI and 13C MRSI at 7 T
    Rutledge, Omar
    Kwak, Tiffany
    Cao, Peng
    Zhang, Xiaoliang
    JOURNAL OF MAGNETIC RESONANCE, 2016, 267 : 15 - 21