Two-dimensional and M-mode echocardiographic parameters in Ghezel sheep

被引:0
|
作者
Roustaei, Ali [1 ]
Hashemi-Asl, Seyed Mohammad [2 ]
Dalir-Naghadeh, Bahram [3 ]
Masoudifard, Majid [4 ]
机构
[1] Urmia Univ, Fac Vet Med, Orumiyeh, Iran
[2] Urmia Univ, Fac Vet Med, Dept Surg & Diagnost Imaging, Orumiyeh, Iran
[3] Urmia Univ, Fac Vet Med, Dept Internal Med & Clin Pathol, Orumiyeh, Iran
[4] Univ Tehran, Fac Vet Med, Dept Surg & Radiol, Tehran, Iran
关键词
Echocardiography; Ghezel sheep; M-mode echocardiography; Two-dimensional echocardiograph; BODY-WEIGHT; REFERENCE VALUES; OVINE MODEL; HEART; LACTATION; VARIABLES; HEALTHY; INDEXES; BREED; AGE;
D O I
10.30466/vrf.2021.89695.2172
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Echocardiography is a non-invasive method of cardiac evaluation in most species. Echocardiographic reference parameters are poorly documented in sheep and not documented in Ghezel sheep. The purpose of this study was to determine reference ranges of normal echocardiographic parameters using two-dimensional and M-mode techniques in Ghezel sheep. In 15 healthy female Ghezel sheep aged between 15 and 18 months, echocardiography was performed in standing position from left and right parasternal approach focused at 3rd - 5th intercostal spaces using a 2.50 - 5.00 MHz phased array transducer. The following parameters were measured in two-dimensional echocardiography: left atrial diameter (LAD), mitral valve annulus (MVA), aortic sinus (AoS), aortic valve (AoV), pulmonary sinus (PuS), and pulmonary valve (PuV); and in M-mode echocardiography: interventricular septum (IVS), left ventricular internal diameter (LVID), left ventricular free wall (LVFW), right ventricle free wall (RVFW), right ventricle internal diameter (RVID). Calculated variables included the ratios LAD/Ao and Pu/AoS, and the fractional shortening (FS), end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF), stroke volume (SV) and cardiac output (CO) of the left ventricle. In conclusion, echocardiographic parameters could be reliably assessed in Ghezel sheep and our study provided some normal echocardiographic reference ranges that might be useful in proper identification, visualization, and measurements of cardiac structures. Such findings could be useful to assess and to diagnose the specific heart diseases in sheep practice and also for experimental studies in sheep as an animal model used for research purposes in cardiovascular studies of human. (C) 2021 Urmia University. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [21] FALSE TENDONS IN THE LEFT-VENTRICLE - TWO-DIMENSIONAL AND M-MODE ECHOCARDIOGRAPHIC FINDINGS
    LINDVALL, K
    OLSSON, G
    SJOGREN, A
    ACTA MEDICA SCANDINAVICA, 1982, 212 (1-2): : 93 - 95
  • [22] STATISTICAL COMPARISON OF THE M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS OF FLAIL MITRAL LEAFLETS
    MINTZ, GS
    KOTLER, MN
    PARRY, WR
    SEGAL, BL
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 435 - 435
  • [23] DIRECT M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DEMONSTRATION OF ACUTE PULMONARY ARTERIAL EMBOLISM
    ERBEL, R
    SCHWEIZER, P
    EFFERT, S
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1981, 106 (06) : 179 - 180
  • [24] FLAIL AORTIC-VALVE LEAFLETS - M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC MANIFESTATIONS
    KRIVOKAPICH, J
    CHILD, JS
    SKORTON, DJ
    AMERICAN HEART JOURNAL, 1980, 99 (04) : 425 - 437
  • [25] Normal electrocardiographic and echocardiographic (M-mode and two-dimensional) values in Polish Landrace pigs
    Urszula Paslawska
    Agnieszka Noszczyk-Nowak
    Robert Paslawski
    Adrian Janiszewski
    Liliana Kiczak
    Dorota Zysko
    Jozef Nicpon
    Ewa A Jankowska
    Andrzej Szuba
    Piotr Ponikowski
    Acta Veterinaria Scandinavica, 56
  • [26] COMBINED TWO-DIMENSIONAL (2-D) AND M-MODE ECHOCARDIOGRAPHIC EVALUATION OF FETAL ARRHYTHMIA
    CROWLEY, D
    PEDIATRIC RESEARCH, 1980, 14 (04) : 442 - 442
  • [27] FUNCTIONAL ASSESSMENT OF THE FONTAN OPERATION - COMBINED M-MODE, TWO-DIMENSIONAL, AND DOPPLER ECHOCARDIOGRAPHIC STUDY
    HAGLER, DJ
    SEWARD, JB
    TAJIK, AJ
    RITTER, DG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 603 - 603
  • [28] Two-dimensional and M-mode echocardiographic predictors of disease severity in dogs with congenital subaortic stenosis
    Oyama, MA
    Thomas, WP
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2002, 38 (03) : 209 - 215
  • [29] M-mode, two-dimensional and Doppler echocardiographic findings in 40 healthy domestic pet rabbits
    Casamian-Sorrosal, Domingo
    Saunders, Richard
    Browne, William J.
    Elliott, Sarah
    Fonfara, Sonja
    JOURNAL OF VETERINARY CARDIOLOGY, 2014, 16 (02) : 101 - 108
  • [30] FUNCTIONAL ASSESSMENT OF THE FONTAN OPERATION - COMBINED M-MODE, TWO-DIMENSIONAL AND DOPPLER ECHOCARDIOGRAPHIC STUDIES
    HAGLER, DJ
    SEWARD, JB
    TAJIK, AJ
    RITTER, DG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (04) : 756 - 764