Anterior Chamber and Lens Position before and after Phacoemulsification According to Axial Length

被引:1
|
作者
Jung, Suk Hoon [1 ]
Kim, Seonjoo [1 ]
Chung, So Hyang [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol, Seoul, South Korea
来源
关键词
Anterior chamber depth; Axial length; Intraocular lens; Long; Short; OPTICAL COHERENCE TOMOGRAPHY; DEPTH; POWER; CATARACT; BIOMETRY; PENTACAM; REPEATABILITY; EYES;
D O I
10.3341/jkos.2020.61.1.17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In this study, we evaluated changes in the anterior chamber structure and lens position before and after phacoemulsification in eyes grouped by axial length (AL). Methods: This study included 65 eyes (16 short eyes [AL < 22.5 mm], 33 normal eyes [22.5 mm < AL < 25.0 mm], and 16 long eyes [AL > 25.5 mm]) that underwent cataract surgery. Pre- and postoperative anterior chamber depth (ACD) was measured using Pentacam (R) and IOL Master (R). In addition, we evaluated the anterior chamber angle (ACA), anterior chamber volume (ACV), epithelium-iris distance, and iris-lens (intraocular lens [IOL]) distance. Results: The change in ACD was significantly smaller in long eyes (Pentacam (R), p = 0.000; IOL Master (R), p = 0.001). The change in ACA was significantly larger in short eyes (p = 0.000), and the change in ACV was significantly smaller in long eyes (p = 0.000). The change in the epithelium-iris distance was significantly smaller in long eyes (p = 0.000), and the change in the iris-lens (IOL) distance was significantly smaller in short eyes (p = 0.000). Conclusions: In short eyes, changes in ACD, ACA, and ACV were found to be larger than those of other groups as the iris moved backward. In long eyes, greater backward movement of the IOL was observed. Therefore, the appropriate IOL power should be chosen, considering the postoperative position of the IOL during cataract surgery of short and long eyes.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [21] Anterior chamber contamination after uncomplicated phacoemulsification and foldable intraocular lens implantation.
    Conklin, J
    Cordahi, GJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 3515 - 3515
  • [22] Anterior chamber fluid cultures following phacoemulsification and posterior chamber lens implantation
    Gimbel, HV
    Sun, R
    DeBroff, BM
    Yang, HM
    OPHTHALMIC SURGERY AND LASERS, 1996, 27 (02): : 121 - 126
  • [23] Anterior chamber flare after trabeculectomy and after phacoemulsification
    Siriwardena, D
    Kotecha, A
    Minassian, D
    Dart, JKG
    Khaw, PT
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (09) : 1056 - 1057
  • [24] Intraocular lens power calculation in eyes with a shallow anterior chamber depth and normal axial length
    Lee, Yunjin
    Kim, Mee Kum
    Oh, Joo Youn
    Choi, Hyuk Jin
    Yoon, Chang Ho
    PLOS ONE, 2023, 18 (07):
  • [25] Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation
    Németh, J
    Fekete, O
    Pesztenlehrer, N
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 85 - 88
  • [26] Intraocular lens power calculation in eyes with shallow anterior chamber depth and normal axial length
    Yun, Young In
    Lee, Yunjin
    Kim, Mee Kum
    Oh, Joo Youn
    Choi, Hyuk Jin
    Yoon, Chang Ho
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [27] Axial length, anterior chamber depth, lens thickness and horizontal corneal diameter in normal children
    Costa, AMC
    Calixto, N
    Milhomens, EG
    Cronemberger, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [28] Changes in anterior chamber depth and axial length measurements after radial keratotomy
    Demirok, A
    Çinal, A
    Simsek, S
    Vasar, T
    Bayram, A
    Yilmaz, OF
    EYE, 1999, 13 (1) : 55 - 58
  • [29] Changes in anterior chamber depth and axial length measurements after radial keratotomy
    Ahmet Demirok
    Adnan Çinal
    Şaban Şimşek
    Tekin Yaşar
    Aysan Bayram
    Ömer Faruk Yilmaz
    Eye, 1999, 13 : 55 - 58
  • [30] The distribution of axial length, anterior chamber depth, lens thickness, and vitreous chamber depth in an adult population of Shahroud, Iran
    Hashemi, Hassan
    Khabazkhoob, Mehdi
    Miraftab, Mohammad
    Emamian, Mohammad Hassan
    Shariati, Mohammad
    Abdolahinia, Tahereh
    Fotouhi, Akbar
    BMC OPHTHALMOLOGY, 2012, 12