LOCAL SETUP ERRORS IN IMAGE-GUIDED RADIOTHERAPY FOR HEAD AND NECK CANCER PATIENTS IMMOBILIZED WITH A CUSTOM-MADE DEVICE

被引:26
|
作者
Giske, Kristina [2 ]
Stoiber, Eva M. [1 ]
Schwarz, Michael [2 ]
Stoll, Armin [2 ]
Muenter, Marc W. [1 ]
Timke, Carmen [1 ,3 ]
Roeder, Falk [1 ,3 ]
Debus, Juergen [1 ]
Huber, Peter E. [1 ,3 ]
Thieke, Christian [1 ,3 ]
Bendl, Rolf [2 ,4 ]
机构
[1] Univ Heidelberg Hosp, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Med Phys Radiat Oncol, D-6900 Heidelberg, Germany
[3] German Canc Res Ctr, Dept Radiat Oncol, D-6900 Heidelberg, Germany
[4] Heilbronn Univ, Heilbronn, Germany
关键词
Head-and-neck cancer; Registration; Setup uncertainties; Radiotherapy; Image-guided radiotherapy; MUTUAL INFORMATION; UNCERTAINTIES; REGISTRATION;
D O I
10.1016/j.ijrobp.2010.07.1980
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. Methods and Materials: A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. Results: The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Conclusions: Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future. (C) 2011 Elsevier Inc.
引用
收藏
页码:582 / 589
页数:8
相关论文
共 50 条
  • [21] Image-guided Biologically Adaptive Therapy for Head and Neck Cancer
    Guerrero, M.
    Carlson, D. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E793 - E793
  • [22] Variation of neck position with image guided radiotherapy for head and neck cancer
    Ove, R.
    Cavalieri, R.
    Noble, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S400 - S400
  • [23] Assessment of Dose Accumulation with Different Deformable Image Registration Algorithms for Image-Guided Radiotherapy of Head and Neck Cancer
    Dogan, N.
    Sleeman, W.
    Asher, D.
    Fatyga, M.
    Schutzer, M.
    Song, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Comparison of daily versus nondaily image-guided radiotherapy protocols for patients treated with intensity-modulated radiotherapy for head and neck cancer
    Yu, Yao
    Michaud, Anthony L.
    Sreeraman, Radhika
    Liu, Tianxiao
    Purdy, James A.
    Chen, Allen M.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2014, 36 (07): : 992 - 997
  • [25] COMPARATIVE ANALYSIS OF AN IMAGE-GUIDED VERSUS A NON IMAGE-GUIDED SETUP APPROACH IN TERMS OF DELIVERED DOSE TO THE PAROTID GLANDS IN HEAD-AND-NECK CANCER IMRT
    Duma, Marciana Nona
    Kampfer, Severin
    Wilkens, Jan Jakob
    Schuster, Tibor
    Molls, Michael
    Geinitz, Hans
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04): : 1266 - 1273
  • [26] SETUP ACCURACY WITH THE USE OF CBCT IMAGE-GUIDED RADIOTHERAPY IN THE TREATMENT OF PROSTATE CANCER
    Dionisi, Francesco
    Bortolato, Barbara
    Bracco, Francesco
    Palazzi, Mauro
    ANTICANCER RESEARCH, 2011, 31 (05) : 1874 - 1875
  • [27] Practice Change after Evaluation of an Offline Correction Protocol for Image-guided Radiotherapy in Head and Neck Cancer
    Forker, L.
    Stratford, J.
    Whitehurst, P.
    Slevin, N.
    Anandadas, C.
    Choudhury, A.
    CLINICAL ONCOLOGY, 2015, 27 (12) : 750 - 751
  • [28] Evaluation of interfraction patient setup errors for image-guided prostate and head-and-neck radiotherapy using kilovoltage cone beam and megavoltage fan beam computed tomography
    Qi, X. Sharon
    Wu, Sutan
    Newman, Francis
    Li, X. Allen
    Hu, Angie Y.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2013, 12 (04) : 334 - 343
  • [29] Using image-guided intensity-modulated radiotherapy on patients with head and neck soft tissue sarcoma
    Elsayad, K.
    Stockmann, D.
    Channaoui, M.
    Scobioala, S.
    Grajda, A.
    Berssenbruegge, H.
    Huss, S.
    Moustakis, C.
    Haverkamp, U.
    Kleinheinz, J.
    Lenz, G.
    Wardelmann, E.
    Eich, H. T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S106 - S107
  • [30] Impact of intensity-modulated and image-guided radiotherapy on elderly patients undergoing chemoradiation for locally advanced head and neck cancer
    Nguyen, N. P.
    Vock, J.
    Chi, A.
    Vinh-Hung, V.
    Dutta, S.
    Ewell, L.
    Jang, S.
    Betz, M.
    Almeida, F.
    Miller, M.
    Davis, R.
    Sroka, T.
    Vo, R. P.
    Karlsson, U.
    Vos, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 677 - 683