Epicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads

被引:7
|
作者
Caliskan, Etem [1 ]
Fischer, Florian [1 ]
Schoenrath, Felix [2 ]
Emmert, Maximilian Y. [1 ]
Maisano, Francesco [1 ]
Falk, Volkmar [2 ]
Starck, Christoph T. [2 ]
Holubec, Tomas [1 ,3 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Clin Cardiovasc Surg, Zurich, Switzerland
[2] German Heart Inst Berlin, Dept Cardiothorac & Vasc Surg, Berlin, Germany
[3] Kerckhoff Heart & Lung Ctr, Dept Cardiac Surg, D-61231 Bad Nauheim, Germany
关键词
Cardiac resynchronization therapy; Left ventricular lead; Steroid eluting lead; Non-steroid eluting lead; Minimally invasive; CARDIAC RESYNCHRONIZATION THERAPY; PACING LEADS; HEART-FAILURE; TASK-FORCE; PERFORMANCE; GUIDELINES; EXPERIENCE; PLACEMENT;
D O I
10.1186/s13019-017-0659-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We retrospectively assessed two types of sutureless screw-in left ventricular (LV) leads (steroid eluting vs. non-steroid eluting) in cardiac resynchronization therapy (CRT) implantation with regards to their electrical performance. Methods: Between March 2008 and May 2014 an epicardial LV lead was implanted in 32 patients after failed transvenous LV lead placement using a left-sided lateral minithoracotomy or video-assisted thoracoscopy (mean age 64 +/- 9 years). Patients were divided into two groups according to the type of implanted lead. Steroid eluting (SE) group: 21 patients (Myodex (TM) 1084 T; St. Jude Medical) and non-steroid eluting (NSE) group: 11 patients (MyoPore (R) 511,212; Greatbatch Medical). Results: All epicardial leads could be placed successfully, without any intraoperative complications or mortality. With regard to the implanted lead following results were observed: sensing (mV): SE 8.8 +/- 6.1 vs. NSE 10.1 +/- 5.3 (p = 0.380); pacing threshold (V@0.5 ms): SE 1.0 +/- 0.5 vs. NSE 0.9 +/- 0.5 (p = 0.668); impedance (ohms): SE 687 +/- 236 vs. NSE 790 +/- 331 (p = 0.162). At the follow-up (2.6 +/- 1.9 years) the following results were seen: sensing (mV): SE 8.7 +/- 5.0 vs. NSE 11.2 +/- 6.6 (p = 0.241), pacing threshold (V@0.5 ms): SE 1.4 +/- 0.5 vs. NSE 1.0 +/- 0.3 (p = 0.035), impedance (ohms): SE 381 +/- 95 vs. NSE 434 +/- 88 (p = 0.129). Conclusions: Based on the results no strong differences have been found between the both types of epicardial LV leads (steroid eluting vs. non-steroid eluting) in CRT implantation in short-and midterm.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] THE LATE EFFECTS OF STEROID-ELUTING LEADS
    TIMMIS, GC
    PARSONNET, V
    GORDON, S
    WESTVEER, DC
    STEWART, JR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A3 - A3
  • [22] Temporary and permanent biventricular pacing via left ventricular epicardial leads implanted during primary cardiac surgery
    Hiroyuki Tanaka
    Kaoru Okishige
    Tomohiro Mizuno
    Kazuyuki Kuriu
    Fusahiko Itoh
    Masato Shimizu
    Hideki Akamatsu
    Noriyuki Tabuchi
    Hirokuni Arai
    Makoto Sunamori
    [J]. The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002, 50 (7): : 284 - 289
  • [23] Long-term follow up of bipolar steroid-eluting epicardial pacing leads in children
    Dodge-Khatami, A.
    Tomaske, M.
    Rahn, M.
    Pretre, R.
    Bauersfeld, U.
    [J]. BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 784 - 784
  • [24] Long-term follow up of bipolar steroid-eluting epicardial pacing leads in children
    Tomaske, M.
    Gerritse, B.
    Kretzers, L.
    Pretre, R.
    Dodge-Khatami, A.
    Rahn, M.
    Bauersfeld, U.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 642 - 642
  • [25] Three year clinical experience with three different steroid-eluting ventricular leads
    Yesil, M
    Bayata, S
    Postaci, N
    Eksi, K
    Susam, I
    [J]. EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 799 - 802
  • [26] Minimally invasive surgical placement of left ventricular epicardial lead: Letter 2
    Mair, H
    Kaczmarek, I
    Oberhoffer, M
    Daebritz, S
    [J]. ANNALS OF THORACIC SURGERY, 2006, 81 (01): : 407 - 408
  • [27] A simplified technique for implantation of left ventricular epicardial leads for biventricular resynchronisation using video-assisted thoracoscopy (VATS)
    Gabor, S
    Prenner, G
    Wasler, A
    Schweiger, M
    Tscheliessnigg, KH
    Smolle-Jüttner, FM
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (06) : 797 - 800
  • [28] Optimal timing for initiation of cardiac resynchronization therapy with left ventricular epicardial pacing leads
    El Sabbagh, Firas H.
    Prabhakaran, Anbazhagan
    Tchou, Patrick J.
    Van Wagoner, David R.
    Navia, Jose L.
    Chung, Mina K.
    [J]. CIRCULATION, 2006, 114 (18) : 674 - 674
  • [29] Robotic Assisted Implantation of Left Ventricular Epicardial Pacing Leads for Cardiac Resynchronization Therapy
    Liao, K.
    Li, X.
    Colvin-Adams, M.
    Boyle, A.
    Missov, E.
    Pritzker, M.
    Lu, F.
    Sakaguchi, S.
    Benditt, D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S97 - S97
  • [30] Five-year follow-up of transvenous and epicardial left ventricular leads: experience with more than 1000 leads
    Burger, Heiko
    Pecha, Simon
    Hakmi, Samer
    Opalka, Bastian
    Schoenburg, Markus
    Ziegelhoeffer, Tibor
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 30 (01) : 74 - 80