Epicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads

被引:7
|
作者
Caliskan, Etem [1 ]
Fischer, Florian [1 ]
Schoenrath, Felix [2 ]
Emmert, Maximilian Y. [1 ]
Maisano, Francesco [1 ]
Falk, Volkmar [2 ]
Starck, Christoph T. [2 ]
Holubec, Tomas [1 ,3 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Clin Cardiovasc Surg, Zurich, Switzerland
[2] German Heart Inst Berlin, Dept Cardiothorac & Vasc Surg, Berlin, Germany
[3] Kerckhoff Heart & Lung Ctr, Dept Cardiac Surg, D-61231 Bad Nauheim, Germany
关键词
Cardiac resynchronization therapy; Left ventricular lead; Steroid eluting lead; Non-steroid eluting lead; Minimally invasive; CARDIAC RESYNCHRONIZATION THERAPY; PACING LEADS; HEART-FAILURE; TASK-FORCE; PERFORMANCE; GUIDELINES; EXPERIENCE; PLACEMENT;
D O I
10.1186/s13019-017-0659-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We retrospectively assessed two types of sutureless screw-in left ventricular (LV) leads (steroid eluting vs. non-steroid eluting) in cardiac resynchronization therapy (CRT) implantation with regards to their electrical performance. Methods: Between March 2008 and May 2014 an epicardial LV lead was implanted in 32 patients after failed transvenous LV lead placement using a left-sided lateral minithoracotomy or video-assisted thoracoscopy (mean age 64 +/- 9 years). Patients were divided into two groups according to the type of implanted lead. Steroid eluting (SE) group: 21 patients (Myodex (TM) 1084 T; St. Jude Medical) and non-steroid eluting (NSE) group: 11 patients (MyoPore (R) 511,212; Greatbatch Medical). Results: All epicardial leads could be placed successfully, without any intraoperative complications or mortality. With regard to the implanted lead following results were observed: sensing (mV): SE 8.8 +/- 6.1 vs. NSE 10.1 +/- 5.3 (p = 0.380); pacing threshold (V@0.5 ms): SE 1.0 +/- 0.5 vs. NSE 0.9 +/- 0.5 (p = 0.668); impedance (ohms): SE 687 +/- 236 vs. NSE 790 +/- 331 (p = 0.162). At the follow-up (2.6 +/- 1.9 years) the following results were seen: sensing (mV): SE 8.7 +/- 5.0 vs. NSE 11.2 +/- 6.6 (p = 0.241), pacing threshold (V@0.5 ms): SE 1.4 +/- 0.5 vs. NSE 1.0 +/- 0.3 (p = 0.035), impedance (ohms): SE 381 +/- 95 vs. NSE 434 +/- 88 (p = 0.129). Conclusions: Based on the results no strong differences have been found between the both types of epicardial LV leads (steroid eluting vs. non-steroid eluting) in CRT implantation in short-and midterm.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Epicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads
    Etem Caliskan
    Florian Fischer
    Felix Schoenrath
    Maximilian Y. Emmert
    Francesco Maisano
    Volkmar Falk
    Christoph T. Starck
    Tomas Holubec
    [J]. Journal of Cardiothoracic Surgery, 12
  • [2] Minimally invasive surgical implantation of left ventricular epicardial leads for ventricular resynchronization using video-assisted thoracoscopy
    Fernández, AL
    García-Bengochea, JB
    Ledo, R
    Vega, M
    Amaro, A
    Alvarez, J
    Rubio, J
    Sierra, J
    Sánchez, D
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2004, 57 (04): : 313 - 319
  • [3] Precipitous exit block with epicardial steroid-eluting leads
    Beder, SD
    Kuehl, KS
    Hopkins, RA
    Tonder, LM
    Mans, DR
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (12): : 2954 - 2957
  • [4] STEROID-ELUTING EPICARDIAL PACING LEADS - AN ALTERNATIVE TO TRANSVENOUS LEADS IN YOUNG-PATIENTS
    JOHNS, JA
    FISH, FA
    GROSS, JP
    BURGER, JD
    STEWART, JR
    [J]. CIRCULATION, 1995, 92 (08) : 3397 - 3397
  • [5] Coronary Sinus Left Ventricular Leads: Endocardial or Epicardial?
    Fisher, John D.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (01): : 1 - 1
  • [6] A survival analysis of bipolar steroid-eluting and unipolar nonsteroid-eluting epicardial leads
    Fazelifar, Amir Farjam
    Taghavyan, Nina Jalily
    Moeeni, Mahdi
    Baharestani, Bahador
    Shahandashti, Farshad Jalili
    Haghjoo, Majid
    Hoseini, Saeed
    Kamali, Farzad
    Madadi, Shabnam
    Yoonesi, Ali Asghar
    Koolaji, Sogol
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (01) : 209 - 218
  • [7] A Minimally Invasive Approach for Placing Sew-On Epicardial Leads in the Child
    Nellis, Joseph R.
    Fitch, Zachary W.
    Choi, Ashley Y.
    Meza, James M.
    Spector, Zebulon Z.
    Von Bergen, Nicholas H.
    Torres, Jose E.
    Klapper, Jacob A.
    Sauer, Jude S.
    Turek, Joseph W.
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2018, 13 (06) : 455 - 457
  • [8] CHRONIC VENTRICULAR ELECTROGRAMS - DO STEROID-ELUTING LEADS DIFFER FROM CONVENTIONAL LEADS
    SCHUCHERT, A
    HOPF, M
    KUCK, KH
    BLEIFELD, W
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 1879 - 1882
  • [9] A comparison of steroid-eluting epicardial versus transvenous pacing leads in children
    Dodge-Khatami, A
    Johnsrude, CL
    Backer, CL
    Deal, BJ
    Strasberger, J
    Mavroudis, C
    [J]. JOURNAL OF CARDIAC SURGERY, 2000, 15 (05) : 323 - 329
  • [10] Surgical implantation of left ventricular epicardial leads for cardiac resynchronization
    García-Bengochea, JB
    Fernández, AL
    Amaro, A
    Alvarez, J
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) : 184 - 185