Using anatomical landmark to avoid phrenic nerve injury during balloon-based procedures in atrial fibrillation patients

被引:8
|
作者
Smith, Nicolina M. [1 ]
Segars, Larry [1 ]
Kauffman, Travis [2 ]
Olinger, Anthony B. [1 ]
机构
[1] Kansas City Univ Med & Biosci, 1750 Independence Ave, Kansas City, MO 64106 USA
[2] Univ Missouri, 5100 Rockhill Rd, Kansas City, MO 64110 USA
关键词
Cryoballoon; Phrenic nerve palsy; Atrial fibrillation; Cardiology; Electrophysiology; PULMONARY VEIN ISOLATION; EXPERT CONSENSUS STATEMENT; CRYOBALLOON ABLATION; CATHETER ABLATION; SURGICAL ABLATION; FOLLOW-UP; PALSY; RECOMMENDATIONS; RADIOFREQUENCY; PREVENTION;
D O I
10.1007/s00276-017-1895-y
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Atrial fibrillation (AF) is an arrhythmia which affects as many as 2.7 million Americans. AF should be treated, because it can lead to a four-to-fivefold increased risk of experiencing a stroke. The American College of Cardiology/American Heart Association guidelines for the treatment of drug refractory and symptomatic paroxysmal AF denote catheter ablation as the standard of care. The newest ablation treatment, cryoballoon, uses a cold balloon tip. The biggest risk factor associated with the cryoballoon ablation is phrenic nerve injury (PNI). The purpose of this study is to measure relevant distances from specific landmarks to the right phrenic nerve (RPN) to create a safe zone for physicians. Using 30 cadaveric specimens, we measured laterally from the right superior pulmonary vein orifice (RSPV) to the RPN at the level of the sixth thoracic vertebra and laterally from the lateral border of the sixth thoracic vertebral body (T6) to the RPN. The depth and width of the left atrium (LA) were also measured to establish a cross-sectional area of the LA. The cross-sectional area of the LA was then correlated with the averaged measurements to see if the area of the LA could be a predictor of the location of the RPN. The average distance from the RPN-RSPV was 9.6 mm (range 4.3-18.8 mm). The average RPN-T6 distance was 30.6 mm (range 13.7-49.9 mm). There was a non-significant trend that suggests as the size of the LA increases, the measured distances also increased. Using the lateral border of the sixth thoracic vertebra as a landmark, which can be viewed under fluoroscopy during the procedure, physicians can triangulate the distance to the RSPV and determine the approximate position of the RPN. Furthermore, physicians can perform a preoperative echocardiogram to determine the size of the LA to assist in determining the position of the RPN with the hopes of avoiding injury to the RPN.
引用
收藏
页码:1369 / 1375
页数:7
相关论文
共 42 条
  • [31] A simple method to detect phrenic nerve impairment during cryoballoon ablation of atrial fibrillation using aVF in the standard surface ECG
    Schaerli, N.
    Knecht, S.
    Spies, F.
    Madaffari, A.
    Osswald, S.
    Sticherling, C.
    Kuehne, M.
    EUROPEAN HEART JOURNAL, 2020, 41 : 606 - 606
  • [32] Prevention of phrenic nerve palsy during cryoballoon ablation in patients with atrial fibrillation - comparison between percutaneous and endovascular electromyographic monitoring technique
    Minden, H-H
    Koenig-Gorsleben, M.
    Schau, T.
    EUROPEAN HEART JOURNAL, 2015, 36 : 569 - 569
  • [33] Clinical Experience With a Novel Electromyographic Approach to Preventing Phrenic Nerve Injury During Cryoballoon Ablation in Atrial Fibrillation (vol 7, pg 605, 2014)
    Shohoudi, Azadeh
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (05): : 995 - 995
  • [34] Clinical experience with a diaphragmatic electromyographic-guided approach to monitor phrenic nerve integrity during cryoballoon-based atrial fibrillation ablation
    Mondesert, B.
    Andrade, J. G.
    Guerra, P. G.
    Rivard, L.
    Macle, L.
    Thibault, B.
    Talajic, M.
    Roy, D.
    Khairy, P.
    Dubuc, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 91 - 91
  • [35] Surgical treatment of atrial fibrillation using argon-based cryoablation during concomitant cardiac procedures
    Mack, CA
    Milla, F
    Ko, W
    Girardi, LN
    Lee, LY
    Tortolani, AJ
    Mascitelli, J
    Krieger, KH
    Isom, OW
    CIRCULATION, 2005, 112 (09) : I1 - I6
  • [36] The surgical treatment of atrial fibrillation using argon-based cryoablation during concomitant cardiac procedures
    Mack, CA
    Milla, F
    Girardi, LN
    Lee, LY
    Ko, W
    Tortolani, AJ
    Krieger, KH
    Isom, OW
    CIRCULATION, 2004, 110 (17) : 692 - 692
  • [37] THE INITIAL CLINICAL EXPERIENCE WITH A DIAPHRAGMATIC ELECTROMYOGRAPHIC-GUIDED APPROACH TO MONITORING PHRENIC NERVE INTEGRITY DURING CRYOBALLOON-BASED ATRIAL FIBRILLATION ABLATION
    Mondesert, B.
    Andrade, J. G.
    Clementy, N.
    Vanella, A.
    Rivard, L.
    Macle, L.
    Roy, D.
    Guerra, P. G.
    Talajic, M.
    Thibault, B.
    Khairy, P.
    Dubuc, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S108 - S108
  • [38] Treatment of atrial fibrillation using second-generation cryo balloon: characteristics of recurrences and periprocedural findings during re-do procedures
    Pajitnev, D. E.
    Neumann, T.
    Greiss, H.
    Deubner, N.
    Akkaya, E.
    Berkowitsch, A.
    Sperzel, J.
    Hamm, C. W.
    Kuniss, M.
    EUROPEAN HEART JOURNAL, 2015, 36 : 736 - 736
  • [39] Anatomic relationships between the phrenic nerve and the pulmonary vein-atrium junction:: implications using newer catheter ablation tools in patients with atrial fibrillation
    Cabrera, JA
    Weiglein, AH
    Sánchez-Quintana, D
    Rubio, JM
    Ibañez, B
    Ho, SY
    De Diego, C
    Farre, J
    EUROPEAN HEART JOURNAL, 2004, 25 : 274 - 274
  • [40] Anatomic relationship between the right phrenic nerve and the pulmonary vein-atrium junction: Implications using newer catheter ablation tools in patients with atrial fibrillation
    Cabrera, JA
    Diaz, FJ
    Sanchez-Quintana, D
    Weiglein, AH
    Rubio, JM
    De Diego, C
    Perez, PP
    Ramirez, P
    Diaz, FJ
    Ho, SY
    Farre, J
    Diaz, FJ
    CIRCULATION, 2004, 110 (17) : 393 - 393