Prediction of refractive outcomes with toric intraocular lens implantation

被引:85
|
作者
Abulafia, Adi [1 ,3 ,6 ]
Barrett, Graham D. [6 ]
Kleinmann, Guy [1 ,5 ]
Ofir, Shay [1 ,3 ,4 ]
Levy, Adi [1 ]
Marcovich, Arie L. [1 ,5 ]
Michaeli, Adi [1 ,2 ,3 ]
Koch, Douglas D. [7 ]
Wang, Li [7 ]
Assia, Ehud I. [1 ,3 ,4 ]
机构
[1] Ein Tal Eye Ctr, Tel Aviv, Israel
[2] Tel Aviv Med Ctr & Sch Med, Tel Aviv, Israel
[3] Tel Aviv Univ, IL-69978 Tel Aviv, Israel
[4] Meir Med Ctr, Kefar Sava, Israel
[5] Kaplan Med Ctr, Rehovot, Israel
[6] Sir Charles Gairdner Hosp, Nedlands, WA 6009, Australia
[7] Baylor Coll Med, Cullen Eye Inst, Houston, TX 77030 USA
来源
关键词
ZONE AUTOMATED KERATOMETRY; POLAR VALUE ANALYSIS; CORNEAL ASTIGMATISM; CORRECTING ASTIGMATISM; CATARACT; SIMULATION; VECTORS; ERROR;
D O I
10.1016/j.jcrs.2014.08.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate and compare the accuracy of different methods to measure and predict postoperative astigmatism with toric intraocular lens (IOL) implantation. SETTING: Ein-Tal Ophthalmology Center, Tel-Aviv, Israel. DESIGN: Retrospective case series. METHODS: Postoperative corneal astigmatism was measured with 3 devices (IOLMaster 500; optical low-coherence reflectometry [OLCR]-based Lenstar LS 900; Atlas topographer) and compared with the manifest astigmatic refractive outcome in patients with toric IOLs. The error in the predicted residual astigmatism was calculated by vector analysis according to the measurement and calculation method used to predict the required toric IOL cylinder power. RESULTS: The centroid errors in predicted residual astigmatism were against the rule with the Alcon and Holladay toric calculators (0.53 to 0.56 diopter [D]), were lower with the Baylor nomogram (0.21 to 0.26 D), and were lowest for the Barrett toric calculator (0.01 to 0.16 D) (P<.001). The Barrett toric calculator had the lowest median absolute error in predicted residual astigmatism (0.35 to 0.54 D, all devices) compared with the Alcon and Holladay toric calculators with or without the Baylor nomogram (P<.021). The Barrett toric calculator and the OLCR device achieved the most accurate results; 75.0% and 97.1% of eyes were within +/- 0.50 D and +/- 0.75 D of the predicted residual astigmatism, respectively. CONCLUSION: Prediction of astigmatic outcomes with toric IOLs can be improved with appropriate measuring devices and methods to establish the required toric IOL power. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:936 / 944
页数:9
相关论文
共 50 条
  • [21] Refractive Lens Exchange with Foldable Toric Intraocular Lens
    Ruiz-Mesa, Ramon
    Carrasco-Sanchez, Daniel
    Diaz-Alvarez, Sara B.
    Angeles Ruiz-Mateos, M.
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) : 990 - 996
  • [22] Clinical outcomes after implantation of a toric intraocular lens with a transitional conic toric surface
    Thomas, Bettina C.
    Khoramnia, Ramin
    Auffarth, Gerd U.
    Holzer, Mike P.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (03) : 313 - 316
  • [23] Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens
    Gundersen, Kjell Gunnar
    Potvin, Rick
    [J]. CLINICAL OPHTHALMOLOGY, 2016, 10 : 455 - 461
  • [24] Long-term refractive outcomes of posterior chamber phakic (spheric and toric implantable collamer lens) intraocular lens implantation
    Arturo Gomez-Bastar
    Martha Jaimes
    Enrique O. Graue-Hernández
    Tito Ramirez-Luquin
    Arturo Ramirez-Miranda
    Alejandro Navas
    [J]. International Ophthalmology, 2014, 34 : 583 - 590
  • [25] Long-term refractive outcomes of posterior chamber phakic (spheric and toric implantable collamer lens) intraocular lens implantation
    Gomez-Bastar, Arturo
    Jaimes, Martha
    Graue-Hernandez, Enrique O.
    Ramirez-Luquin, Tito
    Ramirez-Miranda, Arturo
    Navas, Alejandro
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2014, 34 (03) : 583 - 590
  • [26] Refractive outcomes of posterior chamber phakic (Spheric and toric implantable Collamer lens) intraocular lens implantation with a central port design
    Vera, Guillermo
    Zatarain, Naomi
    Jimenez-Collado, David
    Morales, Carlos
    Ramirez-Miranda, Arturo
    Navas, Alejandro
    Gomez-Bastar, Arturo
    Graue-Hernandez, Enrique
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [27] Real-world refractive outcomes of toric intraocular lens implantation in a United Kingdom National Health Service
    Xue, Kanmin
    Jolly, Jasleen K.
    Mall, Sonia P.
    Haldar, Shreya
    Rosen, Paul H.
    MacLaren, Robert E.
    [J]. BMC OPHTHALMOLOGY, 2018, 18
  • [28] Toric intraocular lens outcomes with a new protocol for IOL selection and implantation
    Clark, K. D.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (02): : 145 - 151
  • [29] Outcomes of cataract surgery with toric intraocular lens implantation after keratoplasty
    Pellegrini, Marco
    Furiosi, Luca
    Yu, Angeli Christy
    Giannaccare, Giuseppe
    Scuteri, Gianfranco
    Gardeli, Ioanna
    Busin, Massimo
    Bovone, Cristina
    Spena, Rossella
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02): : 157 - 161
  • [30] Outcomes of Pseudophakic Toric Intraocular Lens Implantation in Keratoconic Eyes With Cataract
    Nanavaty, Mayank A.
    Lake, Damian B.
    Daya, Sheraz M.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) : 884 - +