Initial density profile measurements using a laser-induced fluorescence diagnostic in the Paul Trap Simulator Experiment

被引:0
|
作者
Chung, M. [1 ]
Gilson, E. P. [1 ]
Davidson, R. C. [1 ]
Efthimion, P. [1 ]
Majeski, R. [1 ]
机构
[1] Princeton Univ, Plasma Phys Lab, Princeton, NJ 08543 USA
来源
2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11 | 2007年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Installation of a laser-induced fluorescence (LIF) diagnostic system has been completed and initial measurements of the beam density profile have been performed on the Paul Trap Simulator Experiment (PTSX). The PTSX device is a linear Paul trap that simulates the collective processes and nonlinear transverse dynamics of an intense charged particle beam propagating through a periodic focusing quadrupole magnetic configuration. Although there are several visible transition lines for the laser excitation of barium ions, the transition from the metastable state has been considered first, mainly because a stable, operating, broadband, and high-power laser system is available for experiments in this region of the red spectrum. The LIF system is composed of a dye laser, fiber optic cables, a line generator, which uses a Powell lens, collection optics, and a CCD camera system. Single-pass mode operation of the PTSX device is employed for the initial tests of the LIF system to make optimum use of the metastable ions. By minimizing the background light level, it is expected that adequate signal-to-noise ratio can be obtained to re-construct the radial density profile of the beam ions.
引用
收藏
页码:1885 / 1887
页数:3
相关论文
共 50 条
  • [21] LASER-INDUCED FLUORESCENCE MEASUREMENTS IN THE PISCES PLASMA
    RETTIG, CL
    PEEBLES, WA
    LUHMANN, NC
    GOHIL, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1536 - 1536
  • [22] Effect of laser intensity upon density and temperature measurements made with laser-induced predissociative fluorescence
    Rothe, EW
    Gu, YW
    OPTICAL TECHNOLOGY IN FLUID, THERMAL, AND COMBUSTION FLOW III, 1997, 3172 : 462 - 466
  • [23] Temperature measurements on droplets in monodisperse stream using laser-induced fluorescence
    P. Lavieille
    F. Lemoine
    G. Lavergne
    J. F. Virepinte
    M. Lebouché
    Experiments in Fluids, 2000, 29 : 429 - 437
  • [24] OH and HO2 measurements using laser-induced fluorescence
    Mather, JH
    Stevens, PS
    Brune, WH
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D5) : 6427 - 6436
  • [25] Concentration measurements of buoyant jets using planar laser-induced fluorescence
    Chu, CR
    Li, KS
    Wu, RS
    ENVIRONMENTAL AND COASTAL HYDRAULICS: PROTECTING THE AQUATIC HABITAT, PROCEEDINGS OF THEME B, VOLS 1 & 2, 1997, 27 : 197 - 202
  • [26] Measurements of optical spectra of TiI using resonance laser-induced fluorescence
    Gangrskii, Yu P.
    Zemlyanoi, S.G.
    Marinova, K.P.
    Markov, B.N.
    Optics and Spectroscopy (English translation of Optika i Spektroskopiya), 1995, 79 (06):
  • [27] Temperature measurements on droplets in monodisperse stream using laser-induced fluorescence
    Lavieille, P
    Lemoine, F
    Lavergne, G
    Virepinte, JF
    Lebouché, M
    EXPERIMENTS IN FLUIDS, 2000, 29 (05) : 429 - 437
  • [28] Atmospheric field measurements of the hydroxylradical using laser-induced fluorescence spectroscopy
    Heard, Dwayne E.
    ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 2006, 57 : 191 - 216
  • [29] Measurements of optical spectra of TiI using resonance laser-induced fluorescence
    Gangrskii, YP
    Zemlyanskii, SG
    Marinova, KP
    Markov, BN
    OPTIKA I SPEKTROSKOPIYA, 1995, 79 (06): : 906 - 911
  • [30] PLASMA ELECTRON-DENSITY MEASUREMENTS BY THE LASER-INDUCED AND COLLISION-INDUCED FLUORESCENCE METHOD
    TSUCHIDA, K
    MIYAKE, S
    KADOTA, K
    FUJITA, J
    PLASMA PHYSICS AND CONTROLLED FUSION, 1983, 25 (09) : 991 - 999