Deep X-ray exposure system with multistage for 3-D microfabrication

被引:2
|
作者
You, H [1 ]
Matsuzuka, N [1 ]
Yamaji, T [1 ]
Tabata, O [1 ]
机构
[1] Ritsumeikan Univ, Fac Sci & Engn, Kusatsu, Shiga 5258577, Japan
来源
MHS 2000: PROCEEDINGS OF THE 2000 INTERNATIONAL SYMPOSIUM ON MICROMECHATRONICS AND HUMAN SCIENCE | 2000年
关键词
D O I
10.1109/MHS.2000.903289
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper reported a new deep X-ray exposure system to realize the 3D microstructures with controllable curved and inclined wall. Based on a compact synchrotron light source, a dedicated X-ray beamline and the exposure device had been constructed. They could work in the exposure environments of vacuum or helium gas. The exposure device was mainly made up of 5 stages and had as many as 6 degree of freedoms, which enabled the system to own much more function than the normal one. Besides the scan In its plan, the substrate surface could also rotate round one of its normal and tangent respectively. Driven by a PZT stage, the X-ray mask could move freely in its plan against the substrate behind, which were used to control the wall inclination and flexure of the substrate structure. The system also had the off-line mask-substrate alignment function. Various 3D PMMA microstructures can be realized by the system, such as lens array, nozzles, tube connector, conical tubes, inclined channels, long circle channels, angle pipe with smooth joint, cone, gear rack, long column with curve cross-section etc., which are impossible for the normal X-ray lithography system. A series of deep X-ray lithography experiments have been completed and obtained some interesting 3D PMMA microstructures and the relationship between the etching depth and the dose energy of the exposure. It demonstrated the potentiality of the system, which will greatly enlarged the application fields of deep x-ray lithography and LIGA process.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [41] 3-D/2-D registration of CT and MR to X-ray images
    Tomazevic, D
    Likar, B
    Slivnik, T
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1407 - 1416
  • [42] Evaluation of 3-D bioactive glass scaffolds dissolution in a perfusion flow system with X-ray microtomography
    Yue, Sheng
    Lee, Peter D.
    Poologasundarampillai, Gowsihan
    Jones, Julian R.
    ACTA BIOMATERIALIA, 2011, 7 (06) : 2637 - 2643
  • [43] 3-D Reconstruction of Historical Documents using an X-Ray C-Arm CT System
    Stromer, Daniel
    Anton, Gisela
    Christlein, Vincent
    Maier, Andreas
    Kugler, Patrick
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2016, : 303 - 308
  • [44] Aligned double exposure in deep X-ray lithography
    Schmidt, A
    Ehrfeld, W
    Lehr, H
    Muller, L
    Reuther, F
    Schmidt, M
    Zetterer, T
    MICROELECTRONIC ENGINEERING, 1996, 30 (1-4) : 235 - 238
  • [45] Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography
    Benz, Robyn Melanie
    Garcia, Meritxell Alzamora
    Amsler, Felix
    Voigt, Johannes
    Fieselmann, Andreas
    Falkowski, Anna Lucja
    Stieltjes, Bram
    Hirschmann, Anna
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [46] Microfabrication of thick tungsten films for use as absorbers of deep X-ray lithography masks
    Okuyama, H
    Hirata, Y
    Takada, H
    MICROSYSTEM TECHNOLOGIES, 2001, 7 (02) : 80 - 84
  • [47] Microfabrication of thick tungsten films for use as absorbers of deep X-ray lithography masks
    H. Okuyama
    Y. Hirata
    H. Takada
    Microsystem Technologies, 2001, 7 : 80 - 84
  • [48] Development of 3-D Shapes Estimation by Using Single X-ray Image
    Cho, Sung Man
    Shim, Hyuk-Hoon
    Kim, Jong-Hyeong
    Song, Chun-Sam
    Kim, Joon Hyun
    Joo, Won Jong
    ISOT: 2009 INTERNATIONAL SYMPOSIUM ON OPTOMECHATRONIC TECHNOLOGIES, 2009, : 335 - +
  • [49] A review of geometric calibration for different 3-D X-ray imaging systems
    Yang, Yao
    Li, Liang
    Chen, Zhi-Qiang
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (03)
  • [50] DIRECT RECORDING AND RECONSTRUCTION OF 3-D X-RAY IMAGES - SOME EXPERIMENTS
    HAMASAKI, J
    YOKOTA, K
    APPLIED OPTICS, 1979, 18 (23): : 4039 - 4045