A Preliminary Study on the Performance of Daylight Responsive Dimming Systems with Improved Closed-Loop Control Algorithm

被引:3
|
作者
Park, Byoung-Chul [1 ]
Choi, An-Seop [1 ]
Jeong, Jae-Won [1 ]
Lee, Eleanor S. [2 ]
机构
[1] Sejong Univ, Dept Architectural Engn, Seoul 143747, South Korea
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Bldg Technol Dept, Berkeley, CA 94720 USA
关键词
Daylight responsive dimming systems; closed-loop proportional controls; daylighting; photoelectric controls; DIFFUSE-RADIATION;
D O I
10.1582/LEUKOS.2011.08.01.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Daylight responsive dimming systems continuously adjust electric lighting output with an algorithm to maintain target illuminance levels at the workplane in combination with available daylight. A key factor of closed-loop proportional control algorithms is the ratio of photosensor response to daylight illuminance at the workplane. This ratio determines in part the control slope (M) between dimming level and lighting output. Although this ratio is known to vary significantly with sun and sky conditions, it is typically set to a fixed value at the time of calibration. Such practice adversely affects the accuracy and therefore reliability of these systems. To investigate how to improve performance, a solstice-to-solstice experiment was conducted in a conventional private office mockup with a large-area, south-facing window and a fixed height roller shade positioned to block direct sun for most hours of the year. This simple preliminary case was used to explore and define the methods for derivation of improved control algorithms with the intent of studying more complex cases in future work. First, variations in the ratio of photosensor signal to daylight workplane illuminance were analyzed using a divided time period, clearness index (K-T) ratio, and the ratio of diffuse solar irradiance to global solar irradiance on an exterior horizontal surface (I-d/I-T). Second, an improved closed-loop proportional control algorithm was suggested based on least square fits to the experimental data assuming that commissioning would occur at targeted times. The performance of this improved algorithm wascompared to a modified conventional control algorithm and found to deliver more reliable, accurate performance when commissioning was performed on two targeted days within the solstice-to-solstice period. For the improved control algorithm when calibrations were performed based on day of the year (June/December), the measured workplane illuminance levels did not fall below 90 percent of the design level for 98.4 percent of the test period. For improved control algorithm when calibrations were performed based on sky conditions (Id/IT ratio for clear and overcast), the measured workplane illuminance levels did not fall below 90 percent of the design level for 99.5 percent of the test period. This study indicates that improvements to the dimming control algorithm and commissioning practices can improve system accuracy and may increase market adoption of the daylight responsive dimming systems.
引用
收藏
页码:41 / 59
页数:19
相关论文
共 50 条
  • [1] Evaluation of a daylight-responsive, iterative, closed-loop light control scheme
    Maiti, P. K.
    Roy, B.
    [J]. LIGHTING RESEARCH & TECHNOLOGY, 2020, 52 (02) : 257 - 273
  • [2] Advanced Dimming Control Algorithm for Sustainable Buildings by Daylight Responsive Dimming System
    Kim, In-Tae
    Kim, Yu-Sin
    Nam, Hyeonggon
    Hwang, Taeyon
    [J]. SUSTAINABILITY, 2018, 10 (11):
  • [3] Development of a daylight responsive dimming system and preliminary evaluation of system performance
    Choi, AS
    Sung, MK
    [J]. BUILDING AND ENVIRONMENT, 2000, 35 (07) : 663 - 676
  • [4] Performance of integrated systems of automated roller shade systems and daylight responsive dimming systems
    Park, Byoung-Chul
    Choi, An-Seop
    Jeong, Jae-Weon
    Lee, Eleanor S.
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (03) : 747 - 757
  • [5] Individualized closed-loop control of propofol anesthesia: A preliminary study
    Soltesz, Kristian
    Hahn, Jin-Oh
    Hagglund, Tore
    Dumont, Guy A.
    Ansermino, J. Mark
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (06) : 500 - 508
  • [6] Closed-loop Performance Diagnosis for Model Predictive Control Systems
    Bombois, Xavier
    Potters, Max
    Mesbah, Ali
    [J]. 2014 EUROPEAN CONTROL CONFERENCE (ECC), 2014, : 264 - 269
  • [7] Pseudo feedforward dynamic matrix control algorithm for desired closed-loop performance in MPC systems
    Shi, Yao
    Zhang, Zhiming
    Chang, Haiying
    Xie, Lei
    Su, Hongye
    [J]. JOURNAL OF PROCESS CONTROL, 2023, 123 : 37 - 49
  • [8] STUDY ON STABILITY OF FUZZY CLOSED-LOOP CONTROL-SYSTEMS
    CHEN, JQ
    CHEN, LJ
    [J]. FUZZY SETS AND SYSTEMS, 1993, 57 (02) : 159 - 168
  • [9] Assessing Control Performance in Closed-loop Anesthesia
    Soltesz, Kristian
    Dumont, Guy A.
    Ansermino, J. Mark
    [J]. 2013 21ST MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2013, : 191 - 196
  • [10] Robustness of closed-loop glucose control systems
    Wycilok, Artur
    Mieja, Jaroslaw