Use of biomaterials in scaphoid fracture fixation, a systematic review

被引:7
|
作者
Feeley, Aoife [1 ,2 ]
Feeley, Iain [3 ]
Ni Fhoghlu, Cliodhna [1 ]
Sheehan, Eoin [1 ]
Kennedy, Muiris [1 ]
机构
[1] Midlands Reg Hosp Tullamore, Dept Orthopaed, Tullamore, Ireland
[2] Univ Coll Dublin, Sch Med, Dublin, Ireland
[3] Natl Orthopaed Hosp Cappagh, Dept Orthopaed, Dublin, Ireland
关键词
Scaphoid fracture; Bioabsorbable materials; Non-union; Biomaterials; Magnesium; Outcomes; FOREIGN-BODY REACTIONS; BIOABSORBABLE SCREWS; CAST IMMOBILIZATION; MAGNESIUM; IMPLANTS; BIODEGRADATION; MULTICENTER; NONUNION; ALLOYS;
D O I
10.1016/j.clinbiomech.2021.105480
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Scaphoid fractures account for 60-70% carpal injury. Due to limited vascular supply achieving adequate reduction and healing is important to avoid complications including avascular necrosis. Recent technological advances have led to renewed vigour in bioabsorbable material research to develop devices which could be used without the need for removal and complications including stress shielding and suboptimal imaging. Methods: A systematic search of databases including PubMed, Ovid Medline, and Google Scholar databases was made to identify studies related to the use of bioabsorbable materials in scaphoid fixation and postoperative patient outcomes. PRISMA guidelines were utilised for this review. Findings: Initial search results yielded 852 studies. 124 studies were screened, with 79 patients across 7 studies included in this review. Poly-L-Lactic acid derivatives were the most common biomaterial for scaphoid fixation, with magnesium and polyglycolide also used. Levels of evidence for studies ranged between III-IV. Analysis demonstrated mixed findings with generally comparable outcomes to conventional alloy-based screws. Interpretation: Development in bioabsorbable materials is ongoing, however there remains a dearth in data regarding their use in the scaphoid. Further research is needed to establish the efficacy and applicability of bioabsorbable devices in the scaphoid bone.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Hip Fracture Management Using External Fixation-A Systematic Review
    Chee, Yu Han
    Foo, Jenies Hui Xin
    Hui, Si Jian
    Tan, Kuang Ian
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2020, 49 (07) : 477 - 488
  • [42] Scaphoid fracture non-union: a systematic review of surgical treatment using bone graft
    Ferguson, D. O.
    Shanbhag, V.
    Hedley, H.
    Reichert, I.
    Lipscombe, S.
    Davis, T. R. C.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2016, 41 (05) : 492 - 500
  • [43] Trans-scaphoid perilunate fracture dislocations: Results of screw fixation of the scaphoid and lunotriquetral repair with a dorsal approach
    Knoll, VD
    Allan, C
    Trumble, TE
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06): : 1145 - 1152
  • [44] FRACTURE OF SCAPHOID
    GRIFFITHS
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1955, 37 (04): : 733 - 733
  • [45] Rethinking Scaphoid Fixation
    Putnam, Jill
    HAND CLINICS, 2023, 39 (04) : 597 - 604
  • [46] A systematic review of the treatment of acute fractures of the scaphoid
    Symes, T. H.
    Stothard, J.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2011, 36E (09) : 802 - 810
  • [47] Scaphoid fracture
    Nakamura, Toshiyasu
    JOURNAL OF WRIST SURGERY, 2020, 9 (06) : 457 - 457
  • [48] How Is Scaphoid Malunion Defined: A Systematic Review
    Xiao, Michelle
    Welch, Jessica M.
    Cohen, Samuel A.
    Kamal, Robin N.
    Shapiro, Lauren M.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023, 18 (2_SUPPL): : 38S - 45S
  • [49] The Natural History of Scaphoid Fracture Malunion: A Scoping Review
    Seltser, Anna
    Suh, Nina
    MacDermid, Joy C.
    Grewal, Ruby
    JOURNAL OF WRIST SURGERY, 2020, 9 (02) : 170 - 176
  • [50] CORONAL FRACTURE OF THE SCAPHOID - A CASE REPORT AND LITERATURE REVIEW
    Ng, Kenneth Cheuk-Kee
    Leung, Yuen-Fai
    Lee, Yuen-Lun
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2014, 19 (03): : 423 - 425