Fractally coated defibrillation electrodes -: Is an improvement in defibrillation threshold possible?

被引:3
|
作者
Gradaus, R [1 ]
Böcker, D
Dorszewski, A
Lamp, B
Hammel, D
Breithardt, G
Block, M
机构
[1] Univ Munster, Med Klin & Poliklin, Dept Cardiol & Angiol, D-48129 Munster, Germany
[2] Univ Munster, Inst Arteriosclerosis Res, D-4400 Munster, Germany
[3] Dept Cardiovasc Surg, Munster, Germany
来源
EUROPACE | 2000年 / 2卷 / 02期
关键词
ICD; defibrillation threshold; fractally coated electrode;
D O I
10.1053/eupc.1999.0084
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In patients with implantable cardioverter-defibrillators (ICD), the goals of lowering the defibrillation threshold (DFT) can be achieved by means of higher defibrillation safety margins. more rapid charging of capacitors, improved battery longevity, implying smaller devices. Whether an increase in the electrically active surface of ICD leads by fractal coating results in decreased DFTs is unknown. Methods and Results In this prospective randomized cross-over study the defibrillation efficacy of a novel right ventricular endocardial defibrillation electrode fractally coated with iridium was compared with an uncoated but otherwise identical electrode in 30 patients undergoing ICD implantation. In each patient, DFT testing was performed twice according to a binary search protocol introducing the two different electrodes in a random order. The mean DFT was 8.4 +/- 4.1 J with the fractally coated lead and 9.6 +/- 3.6 J using the uncoated lead. The improvement of 1.2 J was statistically not significant (P=0.11). No differences were observed between the patients with an improved DFT (n=12) and those with an unchanged or worsened DFT (n=18) concerning age, underlying cardiac disease, NYHA class, or left ventricular ejection fraction, respectively. Conclusion Increasing the electrical surface of defibrillation leads by fractal coating does not lead to a substantial clinically relevant reduction in defibrillation thresholds. Defibrillation impedance is not influenced by the increased electrical surface of the defibrillation lead. (Europace 2000; 2: 154-159) (C) 2000 The European Society of Cardiology.
引用
收藏
页码:154 / 159
页数:6
相关论文
共 50 条
  • [21] THE EFFECT OF AMIODARONE ON DEFIBRILLATION THRESHOLD
    HABERMAN, RJ
    VELTRI, EP
    MOWER, MM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 406 - 406
  • [22] The effect of a passive coronary sinus defibrillation lead on the ventricular defibrillation threshold
    Benser, ME
    Girouard, SD
    Killingsworth, CR
    Walcott, GP
    Ideker, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 122A - 123A
  • [23] TRANS-THORACIC DEFIBRILLATION THRESHOLD OF SINE AND TRAPEZOIDAL WAVEFORMS IN DEFIBRILLATION
    WILSON, CM
    BAILEY, A
    ALLEN, JD
    ANDERSON, J
    ADGEY, AAJ
    JOURNAL OF ELECTROCARDIOLOGY, 1989, 22 (03) : 241 - 247
  • [24] IS THERE AN EFFECT OF AMIODARONE ON THE DEFIBRILLATION THRESHOLD
    GULDAL, M
    KARAOGUZ, R
    AKALIN, H
    BAYAR, M
    AKYOL, T
    JAPANESE HEART JOURNAL, 1993, 34 (02): : 221 - 226
  • [25] Change of defibrillation vector with addition of an azygos vein coil lowers defibrillation threshold
    Jastrzebski, Marek
    Czarnecka, Danuta
    KARDIOLOGIA POLSKA, 2012, 70 (11) : 1202 - 1204
  • [26] ORAL LOADING WITH AMIODARONE INCREASES VENTRICULAR DEFIBRILLATION THRESHOLD WITH IMPLANTED ELECTRODES IN DOGS
    FRAME, LH
    HOFFMAN, N
    KOLENIK, SA
    SHELDON, JH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A82 - A82
  • [27] Thoracotomy elevates the defibrillation threshold and modifies the defibrillation dose-response curve
    Friedman, PA
    Stanton, MS
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (01) : 68 - 73
  • [28] Effect of isoflurane on defibrillation threshold in biphasic active-can defibrillation systems
    Horvath, G
    Ilan, M
    Kadish, A
    Goldberger, J
    JOURNAL OF INVASIVE CARDIOLOGY, 1999, 11 (11): : 700 - 702
  • [29] SEQUENTIAL PULSE DEFIBRILLATION IN HUMANS - ORTHOGONAL SEQUENTIAL PULSE DEFIBRILLATION WITH EPICARDIAL ELECTRODES
    JONES, DL
    KLEIN, GJ
    GUIRAUDON, GM
    SHARMA, AD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (03) : 590 - 596
  • [30] Defibrillation efficacy for spontaneous atrial fibrillation: Relationship of shock strength to defibrillation threshold
    Swerdlow, CD
    Bailin, SJ
    Warman, EN
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 151A - 152A