NOVEL-DESIGN ULTRA-THIN CAD/CAM COMPOSITE RESIN AND CERAMIC OCCLUSAL VENEERS FOR THE TREATMENT OF SEVERE DENTAL EROSION

被引:172
|
作者
Schlichting, Luis Henrique [1 ,2 ]
Maia, Hamilton Pires [2 ]
Baratieri, Luiz Narciso [2 ]
Magne, Pascal
机构
[1] Univ So Calif, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA USA
[2] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2011年 / 105卷 / 04期
关键词
FIXED PARTIAL DENTURES; FATIGUE RESISTANCE; FRACTURE-RESISTANCE; STRESS-DISTRIBUTION; POSTERIOR TEETH; RESTORATIONS; PORCELAIN; CROWNS; ADAPTATION; PLACEMENT;
D O I
10.1016/S0022-3913(11)60035-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Ultra-thin bonded posterior occlusal veneers represent a conservative alternative to traditional inlays and complete coverage crowns for the treatment of severe erosive lesions. There is a lack of data regarding selection of the most appropriate material and its influence on fatigue resistance, which may affect restoration longevity. Purpose. The purpose of this study was to assess the influence of CAD/CAM restorative material (ceramic vs. composite resin) on fatigue resistance of ultra-thin occlusal veneers. Material and methods. A standardized nonretentive tooth preparation (simulating advanced occlusal erosion) was applied to 40 extracted molars including removal of occlusal enamel, and immediate dentin sealing (Optibond FL). All teeth were restored with a 0.6 mm-thick occlusal veneer (Cerec3 chairside CAD/CAM system). Reinforced ceramics (Empress CAD and e.max CAD) and composite resins (Paradigm MZ100 and XR (experimental blocks)) were used to mill the restorations (n=10). The intaglio surfaces were HF-etched and silanated (reinforced ceramics) or airborne-particle abraded and silanated (composite resins). Preparations were airborne-particle abraded and etched before restoration insertion. All restorations were adhesively lured with preheated Filtek Z100. Cyclic isometric loading was applied at 5 Hz, beginning with a load of 200N (x5,000), followed by stages of 400, 600, 800, 1000, 1200 and 1,400N at a maximum of 30,000 cycles each. The number of cycles at initial failure (first cracks) was recorded. Specimens were loaded until catastrophic failure (lost restoration fragment) or to a maximum of 185,000 cycles. Groups were compared using the life table survival analysis (alpha=.008, Bonferroni-method). Results. Empress CAD and e.max CAD initially failed at an average load of SOON and 800N, respectively with no specimen withstanding all 185,000 load cycles (survival 0%); with MZ100 and XR the survival rate was 60% and 100%, respectively. Conclusions. Both composite resins (MZ100 and XR) increased the fatigue resistance of ultra-thin occlusal veneers (P <.001) when compared to the ceramics evaluated (Empress CAD and e.max CAD). (J Prosthet Dent 2011;105:217-226)
引用
收藏
页码:217 / 226
页数:10
相关论文
共 24 条
  • [1] Simplified treatment of severe dental erosion with ultrathin CAD-CAM composite occlusal veneers and anterior bilaminar veneers
    Schlichting, Luis Henrique
    Resende, Tayane Holz
    Reis, Katia Rodrigues
    Magne, Pascal
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (04): : 474 - 482
  • [2] Ultrathin CAD-CAM glass-ceramic and composite resin occlusal veneers for the treatment of severe dental erosion: An up to 3-year randomized clinical trial
    Schlichting, Luis Henrique
    Resende, Tayane Holz
    Reis, Katia Rodrigues
    dos Santos, Aline Raybolt
    Correa, Ivo Carlos
    Magne, Pascal
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (02): : 158.e1 - 158.e12
  • [3] IN VITRO FATIGUE RESISTANCE OF CAD/CAM COMPOSITE RESIN AND CERAMIC POSTERIOR OCCLUSAL VENEERS
    Magne, Pascal
    Schlichting, Luis Henrique
    Maia, Hamilton Pires
    Baratieri, Luiz Narciso
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2010, 104 (03): : 149 - 157
  • [4] Fracture strength of CAD/CAM composite and composite-ceramic occlusal veneers
    Johnson, Andrew C.
    Versluis, Antheunis
    Tantbirojn, Daranee
    Ahuja, Swati
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2014, 58 (02) : 107 - 114
  • [5] Fatigue resistance of ultrathin CAD/CAM ceramic and nanoceramic composite occlusal veneers
    Heck, Katrin
    Paterno, Helena
    Lederer, Alexander
    Litzenburger, Friederike
    Hickel, Reinhard
    Kunzelmann, Karl-Heinz
    [J]. DENTAL MATERIALS, 2019, 35 (10) : 1370 - 1377
  • [6] Resistance of CAD/CAM composite resin and ceramic occlusal veneers to fatigue and fracture in worn posterior teeth: A systematic review
    Maldonado, Karelys Del Cisne
    Espinoza, Juan Andres
    Astudillo, Daniela Andrea
    Delgado, Bolivar Andres
    Bravo, Wilson Daniel
    [J]. DENTAL AND MEDICAL PROBLEMS, 2024, 61 (03) : 417 - 426
  • [7] Full-mouth composite rehabilitation of a mixed erosion and attrition patient: A case report with v-shaped veneers and ultra-thin CAD/CAM composite overlays
    Bahillo, Jose
    Jane, Luis
    Bortolotto, Tissiana
    Krejci, Ivo
    Roig, Miguel
    [J]. QUINTESSENCE INTERNATIONAL, 2014, 45 (09): : 749 - 756
  • [8] Bond strength of CAD/CAM-manufactured composite resin and ceramic veneers to a zirconia framework
    Kimura, Fumiaki
    Komine, Futoshi
    Kubochi, Kei
    Yagawa, Shogo
    [J]. JOURNAL OF ORAL SCIENCE, 2019, 61 (02) : 327 - 334
  • [9] Ultrathin CAD-CAM Ceramic Occlusal Veneers and Anterior Bilaminar Veneers for the Treatment of Moderate Dental Biocorrosion: A 1.5-Year Follow-Up
    Resende, T. H.
    Reis, K. R.
    Schlichting, L. H.
    Magne, P.
    [J]. OPERATIVE DENTISTRY, 2018, 43 (04) : 337 - 346
  • [10] The Influence of a Novel, Crenelated Design of CAD-CAM Ceramic Veneers on the Debonding Strength
    Maroiu, Alexandra-Cristina
    Jivanescu, Anca
    Serban, Dan-Andrei
    Negru, Radu-Marcel
    Duma, Virgil-Florin
    Sinescu, Cosmin
    Rominu, Mihai
    [J]. MATERIALS, 2023, 16 (10)