Detection of Cryptosporidium Oocysts in Micro X-ray Computed Tomography Scans

被引:0
|
作者
Duan, Fei [1 ]
Liu, Tong [2 ]
机构
[1] Nanyang Technol Univ, Div Thermal & Fluids Engn, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[2] Singapore Inst Mfg Technol, Precis Measurements Grp, Singapore 638075, Singapore
来源
关键词
Microwave heating; micro X-ray computed tomography scan; Cryptosporidium oocysts; water; VIABILITY; PARVUM; WATER;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The water containing viable Cryptosporidium oocysts was scanned before or after the microwave heating under a micro X-ray computed tomography system. Cryptosporidium oocysts clusters, found in the specimens without the heating, vanished after 30-second heating when the water temperature approached 100 degree C. After the aqueous specimens were dried, the image analysis indicated that the dried remainder in the specimen without the heating was darker and in rectangular shapes, but whiter and irregular in the specimen after 30-second heating. The preliminary results suggest the low-energy X-ray source should be applied for the aqueous specimens.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [31] Industrial computed X-ray tomography
    Luthi, T
    Flisch, A
    Wyss, P
    INSIGHT, 1998, 40 (03) : 196 - 197
  • [32] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [33] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [34] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [35] X-Ray micro-Computed Tomography and micro X-ray Fluorescence mapping of synthetic emerald by using a laboratory polycapillary optics X-ray tube layout
    Liedl, A.
    Polese, C.
    Hampai, D.
    Della Ventura, G.
    Dabagov, S. B.
    Marcelli, A.
    Bellatreccia, F.
    Cavallo, A.
    X-RAY SPECTROMETRY, 2015, 44 (04) : 201 - 203
  • [36] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [37] Effective X-ray micro computed tomography imaging of carbon fibre composites
    Zwanenburg, E. A.
    Norman, D. G.
    Qian, C.
    Kendall, K. N.
    Williams, M. A.
    Warnett, J. M.
    COMPOSITES PART B-ENGINEERING, 2023, 258
  • [38] Compatibility of X-ray micro-Computed Tomography with soil biological experiments
    Bouckaert, Liesbeth
    Van Loo, Denis
    Ameloot, Nele
    Buchan, David
    Van Hoorebeke, Luc
    Sleutel, Steven
    SOIL BIOLOGY & BIOCHEMISTRY, 2013, 56 : 10 - 12
  • [39] FINDING "PEBBLES" IN BARWELL WITH X-RAY MICRO-COMPUTED TOMOGRAPHY (μCT)
    Almeida, N. V.
    Smith, C. L.
    Sykes, D.
    Downes, H.
    Ahmed, F.
    Russell, S. S.
    METEORITICS & PLANETARY SCIENCE, 2014, 49 : A15 - A15
  • [40] Evaluation of different segmentation methods of X-ray micro computed tomography images
    Bollmann, Sebastian
    Kleinebudde, Peter
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 606