Deep artifact suppression for spiral real-time phase contrast cardiac magnetic resonance imaging in congenital heart disease

被引:8
|
作者
Jaubert, Olivier [1 ,2 ]
Steeden, Jennifer [2 ]
Montalt-Tordera, Javier [2 ]
Arridge, Simon [1 ]
Kowalik, Grzegorz Tomasz [2 ]
Muthurangu, Vivek [2 ]
机构
[1] UCL, Dept Comp Sci, London WC1E 6BT, England
[2] UCL, Ctr Cardiovasc Imaging, Inst Cardiovasc Sci, London WC1N 1EH, England
基金
英国工程与自然科学研究理事会;
关键词
Cardiac MRI; Congenital heart disease; Real time; Flow imaging; Image reconstruction; Machine learning; MRI;
D O I
10.1016/j.mri.2021.08.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Real-time spiral phase contrast MR (PCMR) enables rapid free-breathing assessment of flow. Target spatial and temporal resolutions require high acceleration rates often leading to long reconstruction times. Here we propose a deep artifact suppression framework for fast and accurate flow quantification. Methods: U-Nets were trained for deep artifact suppression using 520 breath-hold gated spiral PCMR aortic datasets collected in congenital heart disease patients. Two spiral trajectories (uniform and perturbed) and two losses (Mean Absolute Error -MAE- and average structural similarity index measurement -SSIM-) were compared in synthetic data in terms of MAE, peak SNR (PSNR) and SSIM. Perturbed spiral PCMR was prospectively acquired in 20 patients. Stroke Volume (SV), peak mean velocity and edge sharpness measurements were compared to Compressed Sensing (CS) and Cartesian reference. Results: In synthetic data, perturbed spiral consistently outperformed uniform spiral for the different image metrics. U-Net MAE showed better MAE and PSNR while U-Net SSIM showed higher SSIM based metrics. In-vivo, there were no significant differences in SV between any of the real-time reconstructions and the reference standard Cartesian data. However, U-Net SSIM had better image sharpness and lower biases for peak velocity when compared to U-Net MAE. Reconstruction of 96 frames took similar to 59 s for CS and 3.9 s for U-Nets. Conclusion: Deep artifact suppression of complex valued images using an SSIM based loss was successfully demonstrated in a cohort of congenital heart disease patients for fast and accurate flow quantification.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [21] CARDIAC MAGNETIC-RESONANCE-IMAGING IN CHILDREN WITH CONGENITAL HEART-DISEASE
    BOXER, RA
    SINGH, S
    LACORTE, MA
    GOLDMAN, M
    STEIN, HL
    JOURNAL OF PEDIATRICS, 1986, 109 (03): : 460 - 464
  • [22] Utility of Cardiac Magnetic Resonance Imaging in the Management of Adult Congenital Heart Disease
    Muscogiuri, Giuseppe
    Secinaro, Aurelio
    Ciliberti, Paolo
    Fuqua, Megan
    Nutting, Arni
    JOURNAL OF THORACIC IMAGING, 2017, 32 (04) : 233 - 244
  • [23] A Deep Learning Segmentation Approach in Free-Breathing Real-Time Cardiac Magnetic Resonance Imaging
    Yang, Fan
    Zhang, Yan
    Lei, Pinggui
    Wang, Lihui
    Miao, Yuehong
    Xie, Hong
    Zeng, Zhu
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [24] Exercise CMR: real-time assessment of cardiac performance with phase contrast imaging
    Marina Quinlan
    Shareen Jaijee
    Antonio de Marvao
    Pawel F Tokarczuk
    J Simon R Gibbs
    Declan O'Regan
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [25] Right heart dilatation in adult congenital heart disease: imaging appearance on cardiac magnetic resonance
    Beitzke, D.
    Wolf, F.
    Edelhauser, G.
    Lammer, J.
    Loewe, C.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (998): : 188 - 193
  • [26] Nomenclature for real-time magnetic resonance imaging
    Dietz, Bryson
    Fallone, B. Gino
    Wachowicz, Keith
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1483 - 1484
  • [27] Real-time functional magnetic resonance imaging
    Cohen, MS
    METHODS, 2001, 25 (02) : 201 - 220
  • [28] Temporospatial characterization of ventricular wall motion with real-time cardiac magnetic resonance imaging in health and disease
    Li, Yu Y.
    Rashid, Shams
    Craft, Jason
    Cheng, Yang J.
    Schapiro, William
    Gliganic, Kathleen
    Yamashita, Ann-Marie
    Grgas, Marie
    Haag, Elizabeth
    Cao, J. Jane
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [29] Temporospatial characterization of ventricular wall motion with real-time cardiac magnetic resonance imaging in health and disease
    Yu Y. Li
    Shams Rashid
    Jason Craft
    Yang J. Cheng
    William Schapiro
    Kathleen Gliganic
    Ann-Marie Yamashita
    Marie Grgas
    Elizabeth Haag
    J. Jane Cao
    Scientific Reports, 12 (1)
  • [30] Real-Time Cardiac Magnetic Resonance Imaging A New Spin on the Evaluation of HFpEF
    Borlaug, Barry A.
    Nelson, Michael D.
    CIRCULATION, 2021, 143 (15) : 1499 - 1501