Improving Interprofessional Consistency in Electronic Fetal Heart Rate Interpretation

被引:2
|
作者
Govindappagari, Shravya [1 ]
Zaghi, Sahar [2 ]
Zannat, Ferdous [2 ]
Reimers, Laura [2 ]
Goffman, Dena [2 ]
Kassel, Irene [3 ]
Bernstein, Peter S. [2 ]
机构
[1] Columbia Univ, Med Ctr, Dept Obstet & Gynecol, New York, NY USA
[2] Montefiore Med Ctr, Albert Einstein Coll Med, Dept Obstet & Gynecol & Womens Hlth, Jack D Weiler Hosp 1825 Eastchester Rd, Bronx, NY 10461 USA
[3] Hosp Insurance Co, New York, NY USA
关键词
electronic fetal monitoring; consistency; variability; accelerations; decelerations; CONTROLLED TRIAL; PROGRAM;
D O I
10.1055/s-0036-1572540
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective To determine if mandatory online training in electronic fetal monitoring (EFM) improved agreement in documentation between obstetric care providers and nurses on labor and delivery. Methods Health care professionals working in obstetrics at our institution were required to complete a course on EFM interpretation. We performed a retrospective chart review of 701 charts including patients delivered before and after the introduction of the course to evaluate agreement among providers in their documentation of their interpretations of the EFM tracings. Results Agreement between provider and nurse documentation at the time of admission improved for variability and accelerations (variability: 91.1 vs. 98.3%, p < 0.001; and accelerations: 75.2 vs. 87.7%, p < 0.001). Similarly, agreement improved at the time of the last note prior to delivery for documentation of variability and accelerations (variability: 82.1 vs. 90.6%, p = 0.001; and accelerations: 56.7 vs. 68.6%, p = 0.0012). Agreement in interpretation of decelerations both at the time of admission and at the time of delivery increased (86.3 vs. 90.6%, p = 0.0787, and 56.7 vs. 61.1%, p = 0.2314, respectively) but was not significant. Conclusion An online EFM course can significantly improve consistency in multidisciplinary documentation of fetal heart rate tracing interpretation.
引用
收藏
页码:808 / 813
页数:6
相关论文
共 50 条
  • [1] Improving consistency in interpretation of electronic fetal heart rate monitoring
    Govindappagari, Shravya
    Zaghi, Sahar
    Zannat, Ferdous
    Goffman, Dena
    Kassel, Irene
    Bernstein, Peter
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S266 - S266
  • [2] Interpretation of the electronic fetal heart rate during labor
    Sweha, A
    Hacker, TW
    Nuovo, J
    AMERICAN FAMILY PHYSICIAN, 1999, 59 (09) : 2487 - 2500
  • [3] Electronic fetal heart rate monitoring: Research guidelines for interpretation
    Parer, JT
    Quilligan, EJ
    Boehm, FH
    Depp, R
    Devoe, LD
    Divon, MY
    Greene, KR
    Harvey, CJ
    Hauth, JC
    Huddleston, JF
    Low, JA
    Martin, CB
    McNellis, D
    Paneth, N
    Paul, RH
    Reed, KL
    Socol, ML
    Vintzileos, AM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 177 (06) : 1385 - 1390
  • [4] Electronic fetal heart rate monitoring: Research guidelines for interpretation
    Sandmire, H
    DeMott, RK
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (01) : 276 - 277
  • [5] Improving fetal heart rate signal interpretation by application of myriad filtering
    Wrobel, Janusz
    Horoba, Krzysztof
    Pander, Tomasz
    Jezewski, Janusz
    Czabanski, Robert
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2013, 33 (04) : 211 - 221
  • [6] Electronic fetal heart rate monitoring: Research guidelines for interpretation - Reply
    Pare, JT
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (01) : 277 - 277
  • [7] Bayesian interpretation of trials: the example of intrapartum electronic fetal heart rate monitoring
    Hornbuckle, J
    Vail, A
    Abrams, KR
    Thornton, JG
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2000, 107 (01): : 3 - 10
  • [8] Improving the interpretation of electronic fetal monitoring: the fetal reserve index
    Evans, Mark I.
    Britt, David W.
    Evans, Shara M.
    Devoe, Lawrence D.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (05) : S1129 - S1143
  • [9] On Electronic Fetal Heart Rate Monitoring
    King, Tekoa L.
    Parer, Julian T.
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2011, 40 (06): : 669 - 671
  • [10] Electronic fetal heart rate monitoring
    Gandhi, Hina
    Kean, Lucy
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2008, 69 (07) : 388 - 391