Improving the interpretation of electronic fetal monitoring: the fetal reserve index

被引:12
|
作者
Evans, Mark I. [1 ,2 ,3 ]
Britt, David W. [1 ]
Evans, Shara M. [1 ,4 ]
Devoe, Lawrence D. [5 ]
机构
[1] Fetal Med Fdn Amer, New York, NY 10075 USA
[2] PLLC, Comprehens Genet, New York, NY 12231 USA
[3] Icahn Sch Med Mt Sinai, Dept Obstet & Gynecol, New York, NY 10029 USA
[4] Univ North Carolina Chapel Hill, Gillings Sch Publ Hlth, Dept Maternal Child Hlth, Chapel Hill, NC USA
[5] Augusta Univ, Dept Obstet & Gynecol, Med Coll Georgia, Augusta, GA USA
关键词
acidosis; augmented electronic fetal monitoring; base excess; cardiotocography; category system; cerebral palsy; electronic fetal monitoring; fetal reserve index; fetal scalp; keeping labor safe; pH; risk factors; sampling; FIGO CONSENSUS GUIDELINES; ST INTERVAL-ANALYSIS; HEART-RATE ANALYSIS; INTRAPARTUM MANAGEMENT; CRITICAL-APPRAISAL; PULSE OXIMETRY; LABOR; SURVEILLANCE; RISK;
D O I
10.1016/j.ajog.2022.11.1275
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Electronic fetal monitoring, particularly in the form of cardiotocography, forms the centerpiece of labor management. Initially successfully designed for stillbirth prevention, there was hope to also include prediction and prevention of fetal acidosis and its sequelae. With the routine use of electronic fetal monitoring, the cesarean delivery rate increased from <5% in the 1970s to >30% at present. Most at-risk cases produced healthy babies, resulting in part from considerable confusion as to the differences between diagnostic and screening tests. Electronic fetal monitoring is clearly a screening test. Multiple attempts have aimed at enhancing its ability to accurately distinguish babies at risk of in utero injury from those who are not and to do this in a timely manner so that appropriate intervention can be performed. Even key electronic fetal monitoring opinion leaders admit that this goal has yet to be achieved. Our group has developed a modified approach called the "Fetal Reserve Index" that contextualizes the findings of electronic fetal monitoring by formally including the presence of maternal, fetal, and obstetrical risk factors and increased uterine contraction frequencies and breaking up the tracing into 4 quantifiable components (heart rate, variability, decelerations, and accelerations). The result is a quantitative 8-point metric, with each variable being weighted equally in version 1.0. In multiple previously published refereed papers, we have shown that in head-to-head studies comparing the fetal reserve index with the American College of Obstetricians and Gynecologists' fetal heart rate categories, the fetal reserve index more accurately identifies babies born with cerebral palsy and could also reduce the rates of emergency cesarean delivery and vaginal operative deliveries. We found that the fetal reserve index scores and fetal pH and base excess actually begin to fall earlier in the first stage of labor than was commonly appreciated, and the fetal reserve index provides a good surrogate for pH and base excess values. Finally, the last fetal reserve index score before delivery combined with early analysis of neonatal heart rate and acid/base balance shows that the period of risk for neonatal neurologic impairment can continue for the first 30 minutes of life and requires much closer neonatal observation than is currently being done.
引用
收藏
页码:S1129 / S1143
页数:15
相关论文
共 50 条
  • [1] Reengineering Electronic Fetal Monitoring Interpretation: Using the Fetal Reserve Index to Anticipate the Need for Emergent Operative Delivery
    Eden, Robert D.
    Evans, Mark I.
    Evans, Shara M.
    Schifrin, Barry S.
    REPRODUCTIVE SCIENCES, 2018, 25 (04) : 487 - 497
  • [2] Reengineering Electronic Fetal Monitoring Interpretation: Using the Fetal Reserve Index to Anticipate the Need for Emergent Operative Delivery
    Robert D. Eden
    Mark I. Evans
    Shara M. Evans
    Barry S. Schifrin
    Reproductive Sciences, 2018, 25 : 487 - 497
  • [3] Improving consistency in interpretation of electronic fetal heart rate monitoring
    Govindappagari, Shravya
    Zaghi, Sahar
    Zannat, Ferdous
    Goffman, Dena
    Kassel, Irene
    Bernstein, Peter
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S266 - S266
  • [4] ELECTRONIC FETAL MONITORING AND INTERPRETATION BY COMPUTER
    LICHTEN, EM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 527 - 527
  • [5] Re-Engineering the Interpretation of Electronic Fetal Monitoring (EFM): Using the Fetal Reserve Index (FRI) to Anticipate the Need for Emergent Operative Delivery (EOD).
    Eden, Robert D.
    Evans, Mark I.
    Evans, Shara M.
    Schifrin, Barry S.
    REPRODUCTIVE SCIENCES, 2017, 24 : 254A - 255A
  • [6] The "Fetal Reserve Index": Re-Engineering the Interpretation and Responses to Fetal Heart Rate Patterns
    Eden, Robert D.
    Evans, Mark I.
    Evans, Shara M.
    Schifrin, Barry S.
    FETAL DIAGNOSIS AND THERAPY, 2018, 43 (02) : 90 - 104
  • [7] Improving Interprofessional Consistency in Electronic Fetal Heart Rate Interpretation
    Govindappagari, Shravya
    Zaghi, Sahar
    Zannat, Ferdous
    Reimers, Laura
    Goffman, Dena
    Kassel, Irene
    Bernstein, Peter S.
    AMERICAN JOURNAL OF PERINATOLOGY, 2016, 33 (08) : 808 - 813
  • [8] Electronic fetal heart rate monitoring: Research guidelines for interpretation
    Parer, JT
    Quilligan, EJ
    Boehm, FH
    Depp, R
    Devoe, LD
    Divon, MY
    Greene, KR
    Harvey, CJ
    Hauth, JC
    Huddleston, JF
    Low, JA
    Martin, CB
    McNellis, D
    Paneth, N
    Paul, RH
    Reed, KL
    Socol, ML
    Vintzileos, AM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 177 (06) : 1385 - 1390
  • [9] Electronic fetal heart rate monitoring: Research guidelines for interpretation
    Sandmire, H
    DeMott, RK
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (01) : 276 - 277
  • [10] Reliability of human interpretation of intrapartum electronic fetal monitoring (EFM)
    Cahill, Alison G.
    Odibo, Anthony O.
    Macones, George A.