Comparing 0.2 tesla with 1.5 tesla intraoperative magnetic resonance imaging: Analysis of setup, workflow, and efficiency

被引:64
|
作者
Nimsky, C [1 ]
Ganslandt, O [1 ]
Fahlbusch, R [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Neurosurg, D-91054 Erlangen, Germany
关键词
functional navigation; intraoperative imaging; resection control; workflow analysis;
D O I
10.1016/j.acra.2005.05.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To compare low-field with high-field intraoperative magnetic resonance imaging (MRI) in respect to setup, workflow, and efficiency. Materials and Methods. A total of 750 patients were investigated either with a 0.2 T (March 1996-July 2001) or a 1.5 T (April 2002-August 2004) MRI system adapted for intraoperative use. Results. With the low-field setup, 330 patients were examined in 65 months; with the high-field setup, 420 patients were examined in 29 months, which is a 2.8-fold increase in cases per month (14.5 versus 5.1) reflecting improved ease of use. Concerning intraoperative workflow, the time for preparation to start intraoperative imaging decreased fivefold (2 minutes instead of 10 minutes); navigation was applied more often with 57% versus 51% (240/420 versus 167/330), whereas functional data were integrated in 35% versus 39% (84/240 versus 65/167). Application of navigation updates was doubled (22% versus 11%; 53/240 versus 18/167). Image acquisition time was reduced by a factor of two, allowing a more detailed imaging protocol, whereas the image quality is clearly improved in the high-field setup, where there was no difference between the standard preoperative image quality compared with the intraoperative quality. This contributed to an increased detection of tumor remnants and extended resections in pituitary (36% versus 29%; 47/129 versus 17/59) and glioma surgery (41% versus 26%; 38/93 versus 28/106). Conclusion. Compared with the low-field setup, the high-field setup results not only in clearly superior image quality and increased imaging armamentarium, contributing to increased rates of detected tumor remnants, but also in a distinct improvement of intraoperative workflow. Furthermore, intraoperative high-field MRI offers various modalities beyond standard anatomic imaging, such as magnetic resonance spectroscopy, diffusion tensor imaging, and functional MRI.
引用
收藏
页码:1065 / 1079
页数:15
相关论文
共 50 条
  • [31] Magnetic resonance (MR) cholangiography - Quantitative and qualitative comparison of 3.0 Tesla with 1.5 Tesla
    Schindera, Sebastian T.
    Miller, Chad M.
    Ho, Lisa M.
    DeLong, David M.
    Merkle, Elmar M.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (06) : 399 - 405
  • [32] Utility of a moveable 1.5 Tesla intraoperative MR imaging system
    Kaibara, T
    Saunders, JK
    Sutherland, GR
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1999, 26 (04) : 313 - 316
  • [33] Detection of partial loss of hippocampal striation at 1.5 Tesla magnetic resonance imaging
    Anitha Sen
    Sudhakaran Sankaran
    Insights into Imaging, 10
  • [34] Detection of partial loss of hippocampal striation at 1.5 Tesla magnetic resonance imaging
    Sen, Anitha
    Sankaran, Sudhakaran
    INSIGHTS INTO IMAGING, 2019, 10 (01)
  • [35] MAGNETIC-RESONANCE-IMAGING (1.5 TESLA) IN PATIENTS WITH INTRACTABLE FOCAL SEIZURES
    LESSER, RP
    MODIC, MT
    WEINSTEIN, MA
    DUCHESNEAU, PM
    LUDERS, H
    DINNER, DS
    MORRIS, HH
    ESTES, M
    CHOU, SM
    HAHN, JF
    ARCHIVES OF NEUROLOGY, 1986, 43 (04) : 367 - 371
  • [36] The utility of cardiovascular magnetic resonance perfusion imaging at 3 Tesla for detection of coronary artery disease: a comparison with 1.5 Tesla
    Cheng, A. S. H.
    Pegg, T. J.
    Karamitsos, T. D.
    Robson, M. D.
    Searle, N.
    Jerosch-Herold, M.
    Choudhury, R. P.
    Banning, A. P.
    Neubauer, S.
    Selvanayagam, J. B.
    EUROPEAN HEART JOURNAL, 2007, 28 : 275 - 275
  • [37] FIBROUS DYSPLASIA - MAGNETIC-RESONANCE-IMAGING APPEARANCE AT 1.5-TESLA
    NORRIS, MA
    KAPLAN, PA
    PATHRIA, M
    GREENWAY, G
    CLINICAL IMAGING, 1990, 14 (03) : 211 - 215
  • [38] Optimizing 1.5-Tesla and 3-Tesla Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Breasts
    Chatterji, Manjil
    Mercado, Cecilia L.
    Moy, Linda
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (02) : 207 - +
  • [39] Comparative magnetic resonance imaging at 1.5 and 3 tesla for the evaluation of traumatic microbleeds
    Scheid, Rainer
    Ott, Derek V.
    Roth, Henrik
    Schroeter, Matthias L.
    Von Cramon, D. Yves
    JOURNAL OF NEUROTRAUMA, 2007, 24 (12) : 1811 - 1816
  • [40] 3-tesla versus 1.5-tesla magnetic resonance diffusion and perfusion imaging in hyperacute ischemic stroke
    Kosior, Robert K.
    Wright, Caitlin J.
    Kosior, Jayme C.
    Kenney, Carol
    Scott, James N.
    Frayne, Richard
    Hill, Michael D.
    CEREBROVASCULAR DISEASES, 2007, 24 (04) : 361 - 368