Comparing 0.2 tesla with 1.5 tesla intraoperative magnetic resonance imaging: Analysis of setup, workflow, and efficiency

被引:64
|
作者
Nimsky, C [1 ]
Ganslandt, O [1 ]
Fahlbusch, R [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Neurosurg, D-91054 Erlangen, Germany
关键词
functional navigation; intraoperative imaging; resection control; workflow analysis;
D O I
10.1016/j.acra.2005.05.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To compare low-field with high-field intraoperative magnetic resonance imaging (MRI) in respect to setup, workflow, and efficiency. Materials and Methods. A total of 750 patients were investigated either with a 0.2 T (March 1996-July 2001) or a 1.5 T (April 2002-August 2004) MRI system adapted for intraoperative use. Results. With the low-field setup, 330 patients were examined in 65 months; with the high-field setup, 420 patients were examined in 29 months, which is a 2.8-fold increase in cases per month (14.5 versus 5.1) reflecting improved ease of use. Concerning intraoperative workflow, the time for preparation to start intraoperative imaging decreased fivefold (2 minutes instead of 10 minutes); navigation was applied more often with 57% versus 51% (240/420 versus 167/330), whereas functional data were integrated in 35% versus 39% (84/240 versus 65/167). Application of navigation updates was doubled (22% versus 11%; 53/240 versus 18/167). Image acquisition time was reduced by a factor of two, allowing a more detailed imaging protocol, whereas the image quality is clearly improved in the high-field setup, where there was no difference between the standard preoperative image quality compared with the intraoperative quality. This contributed to an increased detection of tumor remnants and extended resections in pituitary (36% versus 29%; 47/129 versus 17/59) and glioma surgery (41% versus 26%; 38/93 versus 28/106). Conclusion. Compared with the low-field setup, the high-field setup results not only in clearly superior image quality and increased imaging armamentarium, contributing to increased rates of detected tumor remnants, but also in a distinct improvement of intraoperative workflow. Furthermore, intraoperative high-field MRI offers various modalities beyond standard anatomic imaging, such as magnetic resonance spectroscopy, diffusion tensor imaging, and functional MRI.
引用
收藏
页码:1065 / 1079
页数:15
相关论文
共 50 条
  • [1] 7.0-Tesla Tesla Magnetic Resonance Imaging of Granulomatous Meningoencephalitis in a Maltese Dog: A Comparison with 0.2 and 1.5-Tesla
    Kang, Min-Hee
    Lim, Chae-Young
    Park, Chul
    Yoo, Jong-Hyun
    Kim, Dae-Young
    Park, Hee-Myung
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2009, 71 (11): : 1545 - 1548
  • [2] Functional magnetic resonance imaging at 0.2 Tesla
    Stroman, PW
    Malisza, KL
    Onu, M
    NEUROIMAGE, 2003, 20 (02) : 1210 - 1214
  • [3] Intraoperative magnetic resonance imaging using a mobile 1.5-tesla magnet
    Sutherland, GR
    Louw, DF
    TECHNIQUES IN NEUROSURGERY, 2002, 7 (04): : 299 - 307
  • [4] Magnetic Resonance Imaging of the Placenta at 1.5 Tesla (T).
    Wright, Caroline
    Morris, David M.
    Baker, Philip N.
    Crocker, Ian P.
    Gowland, Penny A.
    Parker, Geoff J.
    Sibley, Colin P.
    REPRODUCTIVE SCIENCES, 2009, 16 (03) : 348A - 348A
  • [5] Clinical 1.5 tesla and "Specialist" 3 tesla magnetic resonance imaging in presurgical epilepsy
    Wieshmann, UC
    Keller, S
    Roberts, N
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2005, 76 (09): : 1315 - 1316
  • [6] Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla
    Frahm, C
    Gehl, HB
    Melchert, UH
    Weiss, HD
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 19 (05) : 335 - 340
  • [7] Correlation of 1.5 Tesla Magnetic Resonance Imaging with Clinical and Intraoperative Findings for Lumbar Disc Herniation
    Dutta, Shumayou
    Bhave, Arvind
    Patil, Sanjay
    ASIAN SPINE JOURNAL, 2016, 10 (06) : 1115 - 1121
  • [8] Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla
    Nöbauer-Huhmann, IM
    Ba-Ssalamah, A
    Mlynarik, V
    Barth, M
    Schöggl, A
    Heimberger, K
    Matula, C
    Fog, A
    Kaider, A
    Trattnig, S
    INVESTIGATIVE RADIOLOGY, 2002, 37 (03) : 114 - 119
  • [9] Pacemaker safety during magnetic resonance imaging at 1.5 Tesla
    Coman, JA
    Martin, ET
    Ramza, BM
    Margolis, PD
    Fair, RD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 436A - 436A
  • [10] CLINICAL BENEFIT OF 3 TESLA MAGNETIC RESONANCE IMAGING RESCANNING IN PATIENTS WITH FOCAL EPILEPSY AND NEGATIVE 1.5 TESLA MAGNETIC RESONANCE IMAGING
    Ladino, Lady D.
    Balaguera, Pedro
    Rascovsky, Simon
    Delgado, Jorge
    Llano, Juan
    Hernandez-Ronquillo, Lizbeth
    Gomez-Arias, Bety
    Tellez-Zenteno, Jose F.
    REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2016, 68 (03): : 112 - 118