Clinical evaluation of small-diameter ITI implants:: A prospective study

被引:0
|
作者
Zinsli, B [1 ]
Sägesser, T [1 ]
Mericske, E [1 ]
Mericske-Stern, R [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prosthodont, CH-3010 Bern, Switzerland
关键词
failures; small-diameter implants;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Dental implants with a reduced diameter are designed for specific clinical situations, such as placement of implants where bone width is narrow or between adjacent teeth that have only a narrow space between them. They are particularly useful when replacing small teeth such as lateral maxillary and mandibular incisors. The aim of the present study was the clinical evaluation of 2-part ITI implants (full-body screws with a 3.3-mm diameter). Materials and Methods: One hundred forty-nine partially or completely edentulous patients received a total of 298 2-part ITI implants over a 10-year period. After a standard healing period (3 to 6 months), the implants were restored with fixed restorations such as single crowns or fixed partial or complete prostheses or overdentures. Complete prosthesis or overdenture in the edentulous jaw was the predominant type of restoration. All patients followed a strict maintenance program, with regular recalls at least once a year. The survival rate of the implants was analyzed, and prosthetic complications were assessed. Results: Three implants were lost during the healing phase on account of peri-implant infection. Two implant body fractures with an osseous length of 8 mm were observed (one after 2 years of observation, the other after 6 years). Four implants exhibited transient peri-implant inflammation that was treated successfully by interceptive therapy. The cumulative 5-year survival rate of the implants was 98.7% (96.6% after 6 years). Prosthetic complications were mostly limited to loose occlusal screws and sore spots caused by the denture base. Discussion: Within the limited observation period, failures of small-diameter implants were infrequent. Prosthetic complications were not dependent on the use of small-diameter implants. Conclusion: The use of 3.3-mm ITI implants appears to be predictable if clinical guidelines are followed and appropriate prosthetic restorations are provided. However, fatigue fracture may occur after a long period of function.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
  • [21] Construction with small-diameter roundwood
    Stern, EG
    FOREST PRODUCTS JOURNAL, 2001, 51 (04) : 71 - 82
  • [22] CONNECTION OF SMALL-DIAMETER TUBINGS
    CHIU, J
    PARKINSON, RA
    ANALYTICAL CHEMISTRY, 1981, 53 (03) : 576 - 576
  • [23] Small-diameter mesocaval shunts: A 10-year evaluation
    Miguel Angel Mercado
    Héctor Orozco
    Erika Guillén-Navarro
    Erik Acosta
    Luz María López-Martinez
    Carlos Hinojosa
    Jorge Hernández
    Manuel Tielve
    Journal of Gastrointestinal Surgery, 2000, 4 : 453 - 457
  • [24] AN EXPERIMENTAL-STUDY OF EVAPORATING SMALL-DIAMETER JETS
    KOWALEWSKI, TA
    HILLER, WJ
    BEHNIA, M
    PHYSICS OF FLUIDS A-FLUID DYNAMICS, 1993, 5 (08): : 1883 - 1890
  • [25] Small-diameter melanomas (micromelanomas): clinical, dermoscopic and histopathological findings
    Vargas-Mora, Pablo
    Gonzalez-Cuevas, Ruben
    Peruilh-Bagolini, Leonardo
    Valenzuela, Fernando
    ANAIS BRASILEIROS DE DERMATOLOGIA, 2022, 97 (01) : 110 - +
  • [26] Design evaluation of multiroll mills for small-diameter wire rolling
    Kuroda, K
    Kuboki, T
    Imamura, Y
    Hayashi, C
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2001, 215 (01) : 77 - 86
  • [27] SMALL-DIAMETER HOLES IN METAL
    WEINTRAUB, M
    KOLLAR, GR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (10): : 986 - 987
  • [28] Small-diameter mesocaval shunts:: A 10-year evaluation
    Mercado, MA
    Orozco, H
    Guillén-Navarro, E
    Acosta, E
    López-Martínez, LM
    Hinojosa, C
    Hernández, J
    Tielve, M
    JOURNAL OF GASTROINTESTINAL SURGERY, 2000, 4 (05) : 453 - 457
  • [29] Machining small-diameter holes
    Mikheev I.I.
    Yarmolenko E.N.
    Russ. Eng. Res., 9 (596-597): : 596 - 597
  • [30] Clinical and dermoscopic features of 135 cases of small-diameter melanomas
    Marusia Capusan, Tania
    Bru, Francisco
    Miguelez, Ana
    Comunion, Alicia
    Gomez, Cristina
    Feito, Marta
    Mayor, Matias
    Sanchez-Carpintero, Ignacio
    Beato-Merino, Maria
    Pizarro, Angel
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2018, 79 (03) : AB75 - AB75