An isotope harvesting beam blocker for the National Superconducting Cyclotron Laboratory

被引:12
|
作者
Domnanich, Katharina A. [1 ,2 ]
Abel, E. Paige [1 ,2 ]
Clause, Hannah K. [1 ,2 ]
Kalman, Colton [2 ]
Walker, Wesley [2 ]
Severin, Gregory W. [1 ,2 ]
机构
[1] Michigan State Univ, Dept Chem, 578 S Shaw Ln, E Lansing, MI 48824 USA
[2] Michigan State Univ, Natl Superconducting Cyclotron Lab, 640 S Shaw Ln, E Lansing, MI 48824 USA
关键词
Beam dump; FRIB; Hydrogen peroxide decomposition; Ion exchange; Isotope harvesting; NSCL; METAL-ORGANIC FRAMEWORKS; HYDROGEN-PEROXIDE; AQUEOUS-SOLUTIONS; WATER RADIOLYSIS; DECOMPOSITION; SUPERNOVAE; SYSTEM;
D O I
10.1016/j.nima.2020.163526
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Harvesting isotopes from beam stops and other activated materials at accelerator facilities is a promising source of environmentally, scientifically and socially important radionuclides. At the Facility for Rare Isotope Beams (FRIB), a multitude of short- and long-lived radionuclides will be collected in a synergistic manner by dumping unused beams into a flowing-water beam stop. Ongoing exploratory research M the National Superconducting Cyclotron Laboratory (NSCL) with an analogous beam blocker aims towards obtaining the necessary radiochemical expertise for this endeavor. Herein we present a beam blocker and an isotope harvesting system which allows collection of a wide variety of aqueous and gaseous radionuclides. The water which flows through the beam blocker functions as an isotope production target and concurrently transports the newly formed radionuclides to collection sites. The system includes analytical instruments for online measurements of conductivity, dissolved oxygen, temperature, pressure and for detection of radiolytic products. To limit the levels of radiolytically produced hydrogen peroxide, a stainless-steel based degradation system was designed and implemented. The suitability of the constructed system for the anticipated radionuclide harvesting project was demonstrated by offline tests and under irradiation with 140 MeV/u Ca-48(20+) ions at the NSCL Coupled Cyclotron Facility.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A superconducting cyclotron as driver for radioactive beam facilities
    Calabretta, L
    Maggiore, M
    Re, M
    Rifuggiato, D
    Farinon, S
    Fabbricatore, P
    Musenich, B
    [J]. NUCLEAR PHYSICS A, 2004, 734 : 378 - 381
  • [22] BEAM PROBES FOR THE CHALK RIVER SUPERCONDUCTING CYCLOTRON
    HEPBURN, JD
    WALSH, JD
    WILLIAMS, EH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 1880 - 1882
  • [23] SUPERCONDUCTING SECTOR CYCLOTRON SUSE FOR THE MUNICH TANDEM LABORATORY
    DANIEL, H
    HUENGES, E
    KIENLE, P
    MORINAGA, H
    NOLTE, E
    SCHEERER, J
    SCHOTT, W
    TRINKS, U
    ZECH, E
    ZIERL, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (03) : 3721 - 3723
  • [24] β-decay measurements of A ≃ 70-110 r-process nuclei at the National Superconducting Cyclotron Laboratory
    Pereira, J.
    Aprahamian, A.
    Arndt, O.
    Becerril, A.
    Elliot, T.
    Estrade, A.
    Galaviz, D.
    Hennrich, S.
    Hosmer, P.
    Kessler, R.
    Kratz, K. -L.
    Lorusso, G.
    Mantica, P. F.
    Matos, M.
    Montes, F.
    Pfeiffer, B.
    Quinn, M.
    Santi, P.
    Schatz, H.
    Schertz, F.
    Schnorrenberger, L.
    Smith, E.
    Stolz, A.
    Walters, W. B.
    Woehr, A.
    [J]. INTERNATIONAL NUCLEAR PHYSICS CONFERENCE 2010 (INPC2010): NUCLEAR ASTROPHYSICS, 2011, 312
  • [25] Optimization of the National Superconducting Cyclotron Laboratory Digital Data Acquisition System for use with fast scintillator detectors
    Prokop, C. J.
    Liddick, S. N.
    Larson, N. R.
    Suchyta, S.
    Tompkins, J. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 792 : 81 - 88
  • [26] NEUTRON BEAM FACILITY FOR MANITOBA CYCLOTRON LABORATORY
    WATSON, JW
    MCKEE, JSC
    RANDELL, C
    ROBERTS, DJ
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (01): : 110 - 110
  • [27] A superconducting cyclotron as a primary accelerator for exotic beam facilities
    Maggiore, M
    Rifuggiato, D
    Calabretta, L
    [J]. NUKLEONIKA, 2003, 48 : S165 - S167
  • [28] BEAM EXTRACTION SYSTEM FOR THE K=500 SUPERCONDUCTING CYCLOTRON
    GORDON, MM
    FABRICI, EM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2101 - 2106
  • [29] Beam-chopping system for LNS superconducting cyclotron
    Calabretta, L
    Caruso, A
    Raia, G
    Sparta, A
    Zappala, E
    Zingale, A
    Khemka, P
    Wei, CY
    [J]. CYCLOTRONS AND THEIR APPLICATIONS 1998, 1999, : 275 - 278
  • [30] SUPERCONDUCTING SECTOR CYCLOTRON SUSE FOR THE MUNICH-TANDEM-LABORATORY
    DANIEL, H
    HUENGES, E
    KIENLE, P
    MORINAGA, H
    NOLTE, E
    SCHEERER, J
    SCHOTT, W
    TRINKS, U
    ZIERL, R
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (02): : 149 - 149