Multimodal Non-Rigid Registration Methods Based on Demons Models and Local Uncertainty Quantification Used in 3D Brain Images

被引:0
|
作者
Reducindo, Isnardo [1 ]
Mejia-Rodriguez, Aldo R. [1 ]
Arce-Santana, Edgar [1 ]
Campos-Delgado, Daniel U. [1 ]
Scalco, Elisa [2 ]
Cattaneo, Giovanni M. [3 ]
Rizzo, Giovanna [2 ]
机构
[1] Univ Autonoma San Luis Potosa, Fac Ciencias, Slp, Mexico
[2] CNR, Inst Mol Bioimaging & Physiol IBFM, I-20133 Milan, Italy
[3] Univ Milan, Osped San Raffaele, Inst Sci, Dept Med Phys, I-20127 Milan, Italy
关键词
MEDICAL IMAGES;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this work, we propose a novel fully automated method to solve the 3D multimodal non-rigid image registration problem. The proposed strategy overcomes the monomodal intensity restriction of fluid-like registration (FLR) models, such as Demons-based registration algorithms, by applying a mapping that relies on an intensity uncertainty quantification in a local neighbourhood, bringing the target and source images into a common domain where they are comparable, no matter their image modalities or mismatched intensities between them. The proposed methodology was tested with T1, T2 and PD weighted brain magnetic resonance (MR) images with synthetic deformations, and CT-MR brain images from a radiotherapy clinical case. The performance of the proposed approach was evaluated quantitatively by standard indices that assess the correct alignment of anatomical structures of interest. The results obtained in this work show that the addition of the local uncertainty mapping properly resolve the monomodal restriction of FLR algorithms when same anatomic counterparts exists in the images to register, and suggest that the proposed strategy can be an option to achieve multimodal 3D registrations.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [21] Non-rigid registration of intraoperatively acquired 3D ultrasound data of brain tumors
    Letteboer, MMJ
    Hellier, P
    Rueckert, D
    Willems, PWA
    Berkelbach, JW
    Niessen, WJ
    [J]. PERSPECTIVE IN IMAGE-GUIDED SURGERY, 2004, : 11 - 18
  • [22] Non-Rigid Registration and Rectification of 3D Laser Scans
    Elseberg, Jan
    Borrmann, Dorit
    Lingemann, Kai
    Nuechter, Andreas
    [J]. IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, : 1546 - 1552
  • [23] 3D Non-rigid Registration for MPU Implicit Surfaces
    Lee, Tung-Ying
    Lai, Shang-Hong
    [J]. 2008 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, VOLS 1-3, 2008, : 991 - 998
  • [24] 3D Non-rigid Surface Matching and Registration Based on Holomorphic Differentials
    Zeng, Wei
    Zeng, Yun
    Wang, Yang
    Yin, Xiaotian
    Gu, Xianfeng
    Samaras, Dimitris
    [J]. COMPUTER VISION - ECCV 2008, PT III, PROCEEDINGS, 2008, 5304 : 1 - +
  • [25] Retrieval of Non-rigid 3D Models Based on Approximated Topological Structure and Local Volume
    Hong, Yiyu
    Kim, Jongweon
    [J]. KSII TRANSACTIONS ON INTERNET AND INFORMATION SYSTEMS, 2017, 11 (08): : 3950 - 3964
  • [26] Non-rigid registration between 3D ultrasound and CT images of the liver based on intensity and gradient information
    Lee, Duhgoon
    Nam, Woo Hyun
    Lee, Jae Young
    Ra, Jong Beom
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01): : 117 - 137
  • [27] Fast non-rigid registration and model-based segmentation of 3D images using mutual information
    Thiran, JP
    Butz, T
    [J]. MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 1504 - 1515
  • [28] Atlas-based segmentation and tracking of 3D cardiac MR images using non-rigid registration
    Lorenzo-Valdés, M
    Sanchez-Ortiz, GI
    Mohiaddin, R
    Rueckert, D
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION-MICCAI 2002, PT 1, 2002, 2488 : 642 - 650
  • [29] Non-rigid registration of 3D multi-channel microscopy images of cell nuclei
    Yang, Siwei
    Koehler, Daniela
    Teller, Kathrin
    Cremer, Thomas
    Le Baccon, Patricia
    Heard, Edith
    Eils, Roland
    Rohr, Karl
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 907 - 914
  • [30] Adaptive non-rigid registration of real time 3D ultrasound to cardiovascular MR images
    Zhang, Weiwei
    Noble, J. Alison
    Brady, J. Mike
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2007, 4584 : 50 - +