Optimal conditions for multifocal VEP recording for normal Japanese population established by receiver operating characteristic analysis

被引:9
|
作者
Ishikawa, Kumiko [1 ]
Nagai, Takayuki [1 ]
Yamada, Yuko [1 ]
Negi, Akira [1 ]
Nakamura, Makoto [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Surg, Div Ophthalmol,Chou Ku, Kobe, Hyogo 6500017, Japan
关键词
Multifocal visual evoked potential; Normative database; Receiver operating characteristic; Ethnic difference; Calcarine fissure; VISUAL-EVOKED-POTENTIALS; AGE-RELATED-CHANGES; GLAUCOMATOUS DAMAGE; TOPOGRAPHY; AMPLITUDE; PERIMETRY;
D O I
10.1007/s10633-010-9252-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study was to establish optimal conditions for recording multifocal visual evoked potentials (mVEPs) in Japanese individuals, whose skull frame presumably differs from Caucasians. The scalp point that was extended from the calcarine fissure was identified using magnetic resonance imaging scans of 200 subjects. MVEPs were recorded from 56 individuals using three single channels and combinations of vertical and horizontal channels. Five electrodes were placed at the inion, 4 cm above the inion, 2.5 cm below the inion, 4 cm to the left or 4 cm to the right of the inion. The signal-to-noise ratio (SNR) was obtained by measuring the root-mean-square (RMS) amplitude of a signal window (45-150 ms) from each of 60-local responses that was divided by the average of the 60 RMS amplitudes of the noise window (325-430 ms). Receiver operating characteristic (ROC) analyses were performed based on the proportion of mVEP responses that exceeded a specific SNR criterion, calculated for both the signal window and the noise window. The position of the calcarine fissure relative to the inion was significantly lower than the value reported for Caucasians. The ROC analyses disclosed that bi-channel combinations (one vertical and one horizontal) had significantly better performance to discriminate signal from noise in 60-local mVEP responses compared to any single channel and performed similarly to the tri-channel combination. Two sets of perpendicular channels should be simultaneously used in recording mVEP responses from Japanese people, among whom skull frame characteristics differ from those observed in Caucasians.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 25 条
  • [21] Use of a prediction method for early pregnancy status utilizing receiver operating characteristic curve analysis of peripheral blood leukocyte interferon-stimulated genes in Japanese-Black cattle
    Yoshino, Hitomi
    Kizaki, Keiichiro
    Iga, Kosuke
    Hirata, Toh-Ichi
    Matsuda, Hideo
    Yamanouchi, Tadayuki
    Hashiyada, Yutaka
    Toji, Noriyuki
    Ishiguro-Oonuma, Toshina
    Takahashi, Toru
    Hashizume, Kazuyoshi
    ANIMAL REPRODUCTION SCIENCE, 2020, 214
  • [22] Right Hepatic Vein Stenosis at Anastomosis in Patients after Living Donor Liver Transplantation: Optimal Doppler US Venous Pulsatility Index and CT Criteria-Receiver Operating Characteristic Analysis
    Hwang, Hye Jeon
    Kim, Kyoung Won
    Jeong, Woo Kyoung
    Song, Gi-Won
    Ko, Gi-Young
    Sung, Kyu Bo
    Shin, Yong Moon
    Kim, Pyo Nyun
    Ha, Tae-Yong
    Moon, Deok-Bog
    Kim, Ki-Hun
    Ahn, Chul-Soo
    Hwang, Shin
    Lee, Sung-Gyu
    RADIOLOGY, 2009, 253 (02) : 543 - 551
  • [23] Evidence-Based Cutoff Threshold Values from Receiver Operating Characteristic Curve Analysis for Knee Osteoarthritis in the 50-Year-Old Korean Population: Analysis of Big Data from the National Health Insurance Sharing Service
    Jee, Hyunseok
    Lee, Hae-Dong
    Lee, Sae Yong
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [24] Determination of the optimal cut-off value of serum prostate-specific antigen in the prediction of skeletal metastases on technetium-99m whole-body bone scan by receiver operating characteristic curve analysis
    Manohar, P. Ram
    Rather, Tanveer Ahmed
    Khan, Shoukat H.
    WORLD JOURNAL OF NUCLEAR MEDICINE, 2020, 19 (03) : 255 - 259
  • [25] Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis
    Nagatani, Yukihiro
    Takahashi, Masashi
    Murata, Kiyoshi
    Ikeda, Mitsuru
    Yamashiro, Tsuneo
    Miyara, Tetsuhiro
    Koyama, Hisanobu
    Koyama, Mitsuhiro
    Sato, Yukihisa
    Moriya, Hiroshi
    Noma, Satoshi
    Tomiyama, Noriyuki
    Ohno, Yoshiharu
    Murayama, Sadayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) : 1401 - 1412