Optimal conditions for multifocal VEP recording for normal Japanese population established by receiver operating characteristic analysis

被引:9
|
作者
Ishikawa, Kumiko [1 ]
Nagai, Takayuki [1 ]
Yamada, Yuko [1 ]
Negi, Akira [1 ]
Nakamura, Makoto [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Surg, Div Ophthalmol,Chou Ku, Kobe, Hyogo 6500017, Japan
关键词
Multifocal visual evoked potential; Normative database; Receiver operating characteristic; Ethnic difference; Calcarine fissure; VISUAL-EVOKED-POTENTIALS; AGE-RELATED-CHANGES; GLAUCOMATOUS DAMAGE; TOPOGRAPHY; AMPLITUDE; PERIMETRY;
D O I
10.1007/s10633-010-9252-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study was to establish optimal conditions for recording multifocal visual evoked potentials (mVEPs) in Japanese individuals, whose skull frame presumably differs from Caucasians. The scalp point that was extended from the calcarine fissure was identified using magnetic resonance imaging scans of 200 subjects. MVEPs were recorded from 56 individuals using three single channels and combinations of vertical and horizontal channels. Five electrodes were placed at the inion, 4 cm above the inion, 2.5 cm below the inion, 4 cm to the left or 4 cm to the right of the inion. The signal-to-noise ratio (SNR) was obtained by measuring the root-mean-square (RMS) amplitude of a signal window (45-150 ms) from each of 60-local responses that was divided by the average of the 60 RMS amplitudes of the noise window (325-430 ms). Receiver operating characteristic (ROC) analyses were performed based on the proportion of mVEP responses that exceeded a specific SNR criterion, calculated for both the signal window and the noise window. The position of the calcarine fissure relative to the inion was significantly lower than the value reported for Caucasians. The ROC analyses disclosed that bi-channel combinations (one vertical and one horizontal) had significantly better performance to discriminate signal from noise in 60-local mVEP responses compared to any single channel and performed similarly to the tri-channel combination. Two sets of perpendicular channels should be simultaneously used in recording mVEP responses from Japanese people, among whom skull frame characteristics differ from those observed in Caucasians.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 25 条
  • [1] Optimal conditions for multifocal VEP recording for normal Japanese population established by receiver operating characteristic analysis
    Kumiko Ishikawa
    Takayuki Nagai
    Yuko Yamada
    Akira Negi
    Makoto Nakamura
    Documenta Ophthalmologica, 2011, 122 : 29 - 37
  • [2] Approach of receiver operating characteristic analysis for estimating optimal radiographic density
    Utsunomiya, A
    Shiraishi, J
    Ueda, H
    RADIOLOGY, 1996, 201 : 805 - 805
  • [3] Receiver-operating characteristic analysis of multifocal VEPs to diagnose and quantify glaucomatous functional damage
    Nakamura, Makoto
    Ishikawa, Kumiko
    Nagai, Takayuki
    Negi, Akira
    DOCUMENTA OPHTHALMOLOGICA, 2011, 123 (02) : 93 - 108
  • [4] Receiver-operating characteristic analysis of multifocal VEPs to diagnose and quantify glaucomatous functional damage
    Makoto Nakamura
    Kumiko Ishikawa
    Takayuki Nagai
    Akira Negi
    Documenta Ophthalmologica, 2011, 123 : 93 - 108
  • [5] RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD
    DORFMAN, DD
    BERBAUM, KS
    METZ, CE
    INVESTIGATIVE RADIOLOGY, 1992, 27 (09) : 723 - 731
  • [6] ON THE GENERALIZATION OF THE RECEIVER OPERATING CHARACTERISTIC ANALYSIS TO THE POPULATION OF READERS AND CASES WITH THE JACKKNIFE METHOD - AN ASSESSMENT
    ROCKETTE, HE
    GUR, D
    KURSLASKY, M
    KING, JL
    ACADEMIC RADIOLOGY, 1995, 2 (01) : 66 - 69
  • [7] Receiver operating characteristic analysis to determine optimal fluid management during open colorectal surgery
    Pache, B.
    Hubner, M.
    Sola, J.
    Hahnloser, D.
    Demartines, N.
    Grass, F.
    COLORECTAL DISEASE, 2019, 21 (02) : 234 - 240
  • [8] Identification of an optimal prolactin threshold to determine prolactinoma size using receiver operating characteristic analysis
    Leca, Bianca M.
    Mytilinaiou, Maria
    Tsoli, Marina
    Epure, Andreea
    Aylwin, Simon J. B.
    Kaltsas, Gregory
    Randeva, Harpal S.
    Dimitriadis, Georgios K.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Identification of an optimal prolactin threshold to determine prolactinoma size using receiver operating characteristic analysis
    Bianca M. Leca
    Maria Mytilinaiou
    Marina Tsoli
    Andreea Epure
    Simon J. B. Aylwin
    Gregory Kaltsas
    Harpal S. Randeva
    Georgios K. Dimitriadis
    Scientific Reports, 11
  • [10] Identification of optimal parameters for first-pass cardiac MRI perfusion measurement by receiver operating characteristic analysis
    Wu, Y
    Post, MJ
    Datta, R
    Gao, L
    Pearlman, JD
    CIRCULATION, 2000, 102 (18) : 687 - 687