INTRAOPERATIVE NEUROMONITORING FOR EARLY LOCALIZATION AND IDENTIFICATION OF RECURRENT LARYNGEAL NERVE DURING THYROID SURGERY

被引:64
|
作者
Chiang, Feng-Yu [2 ,6 ]
Lu, I-Cheng [3 ]
Chen, Hui-Chun [4 ]
Chen, Hsiu-Ya [3 ]
Tsai, Cheng-Jing [3 ]
Lee, Ka-Wo [2 ,6 ]
Hsiao, Pi-Jung [5 ,6 ]
Wu, Che-Wei [1 ,7 ]
机构
[1] Kaohsiung Med Univ, Kaohsiung Municipal Hsiao Kang Hosp, Dept Otolaryngol, Kaohsiung 812, Taiwan
[2] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Otolaryngol, Kaohsiung 812, Taiwan
[3] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Anesthesiol, Kaohsiung 812, Taiwan
[4] Kaohsiung Med Univ, Dept Nursing, Kaohsiung Med Univ Hosp, Kaohsiung 812, Taiwan
[5] Kaohsiung Med Univ, Dept Internal Med, Div Endocrinol & Metab, Kaohsiung Med Univ Hosp, Kaohsiung 812, Taiwan
[6] Kaohsiung Med Univ, Coll Med, Fac Med, Kaohsiung 812, Taiwan
[7] Kaohsiung Med Univ, Inst Clin Med, Kaohsiung 812, Taiwan
来源
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES | 2010年 / 26卷 / 12期
关键词
intraoperative neuromonitoring; laryngeal electromyography; recurrent laryngeal nerve; thyroid surgery; SURGICAL ANATOMY; PALSY; INJURY; DISSECTION; PARALYSIS; GLAND;
D O I
10.1016/S1607-551X(10)70097-8
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Early and definite identification of the recurrent laryngeal nerve (RLN) is an important step to avoid inadvertent nerve injury during complicated thyroid operations. This study aimed to determine the feasibility of routine use of intraoperative neuromonitoring (IONM) to localize and identify the RLN at an early stage of thyroid surgery. This prospective study enrolled 220 consecutive patients (333 RLNs at risk) who underwent thyroid operations with application of IONM. The RLN was localized and identified routinely with a nerve stimulator after opening the space between the thyroid and carotid sheath. The success rates of early RLN localization and identification were evaluated. The current for localization and the amplitude of evoked laryngeal electromyographic signals were also recorded and analyzed. All RLNs, including 87 (26%) nerves that were regarded as difficult to identify, were successfully localized and identified. The stimulation level for RLN localization was 2mA in 315 nerves (95%) and 3mA in the other 18 nerves (5%). The signal obtained from RLN localization (amplitude = 932 +/- 436 mu V) showed a clear and reliable laryngeal electromyographic response that was similar to that from direct vagus (amplitude = 811 +/- 389 mu V) or RLN stimulation (amplitude = 1132 +/- 472 mu V). The palsy rate was 0.6% and no permanent palsy occurred. RLN injury is rare if the nerve is definitely identified early in the thyroid operation. The conclusion of this study is that IONM is a reliable tool for early RLN localization and identification, even in complicated thyroid operations.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 50 条
  • [31] Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery
    Salmoiraghi, F.
    Peloni, G.
    Brenna, M.
    Fasolini, F.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 17 - 17
  • [32] Intraoperative Monitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery
    H. Dralle
    C. Sekulla
    K. Lorenz
    M. Brauckhoff
    A. Machens
    World Journal of Surgery, 2008, 32 : 1358 - 1366
  • [33] Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery
    Dralle, H.
    Sekulla, C.
    Lorenz, K.
    Brauckhoff, M.
    Machens, A.
    WORLD JOURNAL OF SURGERY, 2008, 32 (07) : 1358 - 1366
  • [34] Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery
    Farris, S.
    Tatti, A.
    Piga, G.
    Podda, M.
    Calo, P. G.
    Pisano, G.
    Nicolosi, A.
    GIORNALE DI CHIRURGIA, 2010, 31 (6-7): : 353 - 353
  • [35] Intraoperative neuromonitoring by vagus nerve stimulation in thyroid surgery: Clinical assessment of recurrent and superior laryngeal nerves
    Prades, J. -M.
    Lelonge, Y.
    Farizon, B.
    Dubois, M. -D.
    Gavid, M.
    EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2020, 137 (03) : 227 - 230
  • [36] Recurrent Laryngeal Nerve Intraoperative Neuromonitoring Indications in Non-Thyroid and Non-Parathyroid Surgery
    Brunet, Aina
    Rovira, Aleix
    Quer, Miquel
    Sanabria, Alvaro
    Guntinas-Lichius, Orlando
    Zafereo, Mark
    Hartl, Dana M.
    Coca-Pelaz, Andres
    Shaha, Ashok R.
    Marie, Jean-Paul
    Vander Poorten, Vincent
    Piazza, Cesare
    Kowalski, Luiz P.
    Randolph, Gregory W.
    Shah, Jatin P.
    Rinaldo, Alessandra
    Simo, Ricard
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [37] Training in intraoperative neuromonitoring of recurrent laryngeal nerves reduces the risk of their injury during thyroid surgery
    Kuryga, Dorota
    Wojskowicz, Piotr
    Szymczuk, Jaroslaw
    Wojdyla, Anna
    Milewska, Anna J.
    Barczynski, Marcin
    Dadan, Jacek
    Rogowski, Marek
    Mysliwiec, Piotr
    ARCHIVES OF MEDICAL SCIENCE, 2021, 17 (05) : 1294 - 1302
  • [38] Continuous intraoperative neuromonitoring of the recurrent laryngeal nerve during lung operations
    Kirschbaum, Andreas
    Jochens, Nora
    Stay, David
    Meyer, Christian
    Bartsch, Detlef K.
    JOURNAL OF THORACIC DISEASE, 2023, 15 (08) : 4198 - 4206
  • [39] Recurrent laryngeal nerve identification and assessment during thyroid surgery: Laryngeal palpation
    Randolph, GW
    Kobler, JB
    Wilkins, J
    WORLD JOURNAL OF SURGERY, 2004, 28 (08) : 755 - 760
  • [40] Recurrent Laryngeal Nerve Identification and Assessment during Thyroid Surgery: Laryngeal Palpation
    Gregory W. Randolph
    James B. Kobler
    Jamie Wilkins
    World Journal of Surgery, 2004, 28 : 755 - 760