Phase-Contrast MRI: Physics, Techniques, and Clinical Applications

被引:107
|
作者
Wymer, David T. [1 ]
Patel, Kunal P. [1 ]
Burke, William F., III [1 ]
Bhatia, Vinay K. [1 ]
机构
[1] Mt Sinai Med Ctr, Dept Diagnost Radiol, 4300 Alton Rd, Miami Beach, FL 33140 USA
关键词
MAGNETIC-RESONANCE ELASTOGRAPHY; 4D FLOW MRI; STAGING LIVER FIBROSIS; VISUALIZATION; HEMODYNAMICS;
D O I
10.1148/rg.2020190039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With phase-contrast imaging, the MRI signal is used to visualize and quantify velocity. This imaging modality relies on phase data, which are intrinsic to all MRI signals. With use of bipolar gradients, degrees of phase shift are encoded and in turn correlated directly with the velocity of protons. The acquisition of diagnosticquality images requires selection of the correct imaging plane to ensure accurate measurement and selection of the encoding velocity and thus prevent aliasing and achieve the highest signalto-noise ratio. Multiple applications of phase-contrast imaging are actively used in clinical practice. One of the most common clinical uses is in cardiac valvular flow imaging, at which the data are used to assess the severity of valvular disease and quantify the shunt fraction. In neurologic imaging, phase-contrast imaging can be used to measure the flow of cerebrospinal fluid. This measurement can aid in the diagnosis and direct management of normal pressure hydrocephalus or be used to evaluate the severity of stenosis, such as that in Chiari I malformations. At vascular analysis, phase-contrast imaging can be used to visualize arterial and venous flow, and this application is used most commonly in the brain. Three-dimensional imaging can yield highly detailed flow data in a technique referred to as four-dimensional flow. A more recently identified application is in MR elastography. Shear waves created by using an impulse device can be velocity encoded, and this velocity is directly proportional to the stiffness of the organ, or the shear modulus. This imaging modality is most commonly used in the liver for evaluation of cirrhosis and steatosis, although research on the assessment of other organs is being performed. Phase-contrast imaging is an important tool in the arsenal of MRI examinations and has many applications. Proper use of phasecontrast imaging requires an understanding of the many practical and technical factors and unique physics principles underlying the technique. (C) RSNA, 2020 center dot radiographics.rsna.org
引用
收藏
页码:122 / 140
页数:19
相关论文
共 50 条
  • [21] Optimal Dual-VENC Unwrapping in Phase-Contrast MRI
    Carrillo, Hugo
    Osses, Axel
    Uribe, Sergio
    Bertoglio, Cristobal
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (05) : 1263 - 1270
  • [22] Quantification of neurovascular compliance with retrospectively gated phase-contrast MRI
    Nabbout, Marianne
    Langham, Michael C.
    Cottrell, Christiana
    Wehrli, Felix W.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (02) : 307 - 314
  • [23] Quantification of neurovascular compliance with retrospectively gated phase-contrast MRI
    Marianne Nabbout
    Michael C. Langham
    Christiana Cottrell
    Felix W. Wehrli
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2024, 37 : 307 - 314
  • [24] Vorticity imaging of diastolic cardiac inflow by phase-contrast MRI
    Kerwin, W
    Hertzberg, J
    Cooke, J
    Chluda, H
    Shandas, R
    Gill, E
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 300 - 303
  • [25] Diagnosing Carotid Near-Occlusion with Phase-Contrast MRI
    Johansson, E.
    Zarrinkoob, L.
    Wahlin, A.
    Eklund, A.
    Malm, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (05) : 927 - 929
  • [26] PHASE-CONTRAST MRI ASSESSMENT OF PEDAL BLOOD-FLOW
    DEBATIN, JF
    DALMAN, R
    HERFKENS, RJ
    HARRIS, EJ
    PELC, NJ
    EUROPEAN RADIOLOGY, 1995, 5 (01) : 36 - 42
  • [27] A phase-contrast MRI study of physiologic cerebral venous flow
    Stoquart-ElSankari, Souraya
    Lehmann, Pierre
    Villette, Agnes
    Czosnyka, Marek
    Meyer, Marc-Etienne
    Deramond, Herve
    Baledent, Olivier
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 (06): : 1208 - 1215
  • [28] ICP Monitoring and Phase-Contrast MRI to Investigate Intracranial Compliance
    Lokossou, A.
    Baledent, O.
    Garnotel, S.
    Page, G.
    Balardy, L.
    Czosnyka, Z.
    Payoux, P.
    Schmidt, E. A.
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 247 - 253
  • [29] Advanced phase-contrast techniques for wavefront sensing and adaptive optics
    Vorontsov, MA
    Justh, EW
    Beresnev, LA
    HIGH-RESOLUTION WAVEFRONT CONTROL: METHODS, DEVICES, AND APPLICATIONS II, 2000, 4124 : 98 - 109
  • [30] Spatiotemporal Phase Unwrapping for Real-Time Phase-Contrast Flow MRI
    Untenberger, Markus
    Huellebrand, Markus
    Tautz, Lennart
    Joseph, Arun A.
    Voit, Dirk
    Merboldt, K. Dietmar
    Frahm, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 964 - 970