Development of a Novel Corneal Concavity Shape Parameter and Its Association with Glaucomatous Visual Field Progression

被引:5
|
作者
Aoki, Shuichiro [1 ]
Murata, Hiroshi [2 ]
Nakakura, Shunsuke [3 ]
Nakao, Yoshitaka [4 ]
Matsuura, Masato [2 ,5 ]
Fujino, Yuri [2 ]
Kiuchi, Yoshiaki [4 ]
Asaoka, Ryo [2 ]
机构
[1] Sapporo City Gen Hosp, Dept Ophthalmol, Sapporo, Hokkaido, Japan
[2] Univ Tokyo, Dept Ophthalmol, Grad Sch Med, Tokyo, Japan
[3] Saneikai Tsukazaki Hosp, Dept Ophthalmol, Himeji, Hyogo, Japan
[4] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
[5] Kitasato Univ, Sch Allied Hlth Sci, Dept Rehabil, Orthop & Visual Sci, Sagamihara, Kanagawa, Japan
来源
OPHTHALMOLOGY GLAUCOMA | 2019年 / 2卷 / 01期
基金
日本科学技术振兴机构;
关键词
DEFORMATION PARAMETERS; BIOMECHANICAL PROPERTIES; INTRAOCULAR-PRESSURE; LAMINA-CRIBROSA; HYSTERESIS; THICKNESS; KERATOCONUS; REDUCTION; TONOMETER; RATES;
D O I
10.1016/j.ogla.2018.10.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop a novel Corvis ST (Oculus Co. Ltd, Wetzlar, Germany) corneal concavity shape parameter (concavity shape index [CSI]) and investigate its association with glaucomatous visual field (VF) progression. Design: Retrospective longitudinal study. Participants: A total of 103 eyes with primary open-angle glaucoma in 68 patients with 8 reliable VFs using the Humphrey Field Analyzer (HFA) (Carl Zeiss Meditec Inc, Dublin, CA). Methods: The mean total deviation (mTD) of the 52 test points in the 24-2 HFA test pattern was calculated for each VF, and the mTD progression rate was determined. A Corvis ST measurement was performed, and CSI was calculated as the ratio of (peak distance x curvature radius at the time of highest concavity [HC] state) to (the deflection amplitude at the time of HC x curvature radius at the undeformed state). The association between mTD progression rate and CSI, as well as other variables (including age, intraocular pressure, corneal hysteresis [CH], and 35 standard Corvis ST parameters), was investigated using the linear mixed model. The optimal linear mixed model to describe mTD progression rate was selected using the Random Forest method followed by variable selection using the second order bias corrected Akaike Information Criterion (AICc) index. Main Outcome Measures: Optimal linear mixed models for the mTD progression rate, as determined by AICc index. Results: Univariate analysis revealed mTD progression rate was significantly associated with CSI (P = 0.0042), CH, HC radius, A1 deflection length, max inverse radius, and integrated radius. The optimal model to describe mTD progression rate included CSI, max inverse radius, Ambrosio rational thickness horizontal, and age (AICc = 41.59). Conclusions: A novel corneal concavity shape parameter, CSI, was closely related to glaucomatous VF progression. (C) 2018 by the American Academy of Ophthalmology
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [21] Patterns of glaucomatous visual field progression identified by three progression criteria
    Boden, C
    Blumenthal, EZ
    Pascual, J
    McEwan, G
    Weinreb, RN
    Medeiros, F
    Sample, PA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (06) : 1029 - 1036
  • [22] Predictive factors of the optic nerve head for development or progression of glaucomatous visual field loss
    Jonas, JB
    Martus, P
    Horn, FK
    Jünemann, A
    Korth, M
    Budde, WM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (08) : 2613 - 2618
  • [23] Predictive factors of the optic nerve head for development or progression of glaucomatous visual field loss
    Kamppeter, BA
    Jonas, JB
    Martus, P
    Horn, FK
    Jünemann, A
    Korth, M
    Budde, WM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U448 - U448
  • [24] A VIDEOGRAPHIC TECHNIQUE FOR THE DETERMINATION OF GLAUCOMATOUS VISUAL-FIELD PROGRESSION
    CHAUHAN, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1264 - 1264
  • [25] Comparison of Methods to Detect and Measure Glaucomatous Visual Field Progression
    Rabiolo, Alessandro
    Morales, Esteban
    Mohamed, Lilian
    Capistrano, Vicente
    Kim, Ji Hyun
    Afifi, Abdelmonem
    Yu, Fei
    Coleman, Anne L.
    Nouri-Mandavi, Kouros
    Caprioli, Joseph
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (05):
  • [26] ASSOCIATION OF RELIABILITY WITH REPRODUCIBILITY OF THE GLAUCOMATOUS VISUAL-FIELD
    MCMILLAN, TA
    STEWART, WC
    HUNT, HH
    ACTA OPHTHALMOLOGICA, 1992, 70 (05): : 665 - 670
  • [27] The influence of infrequent testing on detecting glaucomatous visual field progression
    Anderson, Andrew J.
    Asokan, Rashima
    Murata, Hiroshi
    Asaoka, Ryo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [28] Comparison of different methods for detecting glaucomatous visual field progression
    Vesti, E
    Johnson, CA
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (09) : 3873 - 3879
  • [29] Comparison of methods to detect glaucomatous visual field progression.
    Hoffman, DC
    Westcott, M
    Gaasterland, D
    Caprioli, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S152 - S152
  • [30] Automatic detection of glaucomatous visual field progression with neural networks
    Brigatti, L
    NouriMahdavi, K
    Weitzman, M
    Caprioli, J
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (06) : 725 - 728