Roebling Suspension Bridge. II: Ambient Testing and Live-Load Response

被引:54
|
作者
Ren, Wei-Xin [2 ,3 ]
Harik, Issam E. [1 ]
Blandford, George E. [1 ]
Lenett, M. [4 ]
Baseheart, T. M. [5 ]
机构
[1] Univ Kentucky, Dept Civil Engn, Lexington, KY 40506 USA
[2] Fuzhou Univ, Dept Civil Engn, Fuzhou 350002, Fujian, Peoples R China
[3] Cent S Univ, Dept Civil Engn, Changsha, Hunan, Peoples R China
[4] URS Corp, Cincinnati, OH 45221 USA
[5] Univ Cincinnati, Dept Civil & Environm Engn, Cincinnati, OH 45221 USA
关键词
Bridges; suspension; Finite element method; Vibration; Natural frequency; Bridge tests; Bearing capacity; Evaluation; Ohio; Kentucky;
D O I
10.1061/(ASCE)1084-0702(2004)9:2(119)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This is the second part of a two-part paper on the evaluation of the historic Roebling suspension bridge using dynamic-analysis techniques. Dynamic properties are determined using ambient field testing under natural excitation. The finite-element (FE) model described in the first part of this two-part paper is modified to more accurately represent current bridge properties. Modifications of the model are based on correlating the FE model frequencies with ambient test frequencies by adjusting the FE model stiffness parameters. The updated 3D FE model is subsequently subjected to an extreme live-load condition to evaluate static safety margins. In addition, cable areas are reduced by 10 to 40% to simulate further deterioration and corrosion. The safety margin of the main cables is demonstrated to be good even when assuming a very conservative 40% cable area reduction, and truss member forces remain within the maximum load-carrying capacity even when the cable areas are reduced by 40%.
引用
收藏
页码:119 / 126
页数:8
相关论文
共 50 条
  • [31] Determination of main cable shape and hanger tensions of a suspension bridge based on the measured live-load deflection of the main beam: An analytical algorithm
    Zhang, Wen-ming
    Chang, Jia-qi
    Feng, Dan-dian
    [J]. ENGINEERING STRUCTURES, 2022, 272
  • [32] Live-load distribution factors for prestressed concrete, spread box-girder bridge
    Hughs, Erin
    Idriss, Rola
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2006, 11 (05) : 573 - 581
  • [33] Evaluation of live-load deflection criteria for I-shaped steel bridge girders
    Barth, KE
    Roeder, CW
    Christopher, RA
    Wu, HY
    [J]. HIGH PERFORMANCE MATERIALS IN BRIDGES, 2003, : 193 - 208
  • [34] Development of Traffic Live-Load Models for Bridge Superstructure Rating with RBDO and Best Selection Approach
    Siavashi, Sasan
    Eamon, Christopher D.
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2019, 24 (08)
  • [35] Evaluation of live-load lateral flange bending distribution for a horizontally curved I-girder bridge
    DePolo, David S.
    Linzell, Daniel G.
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2008, 13 (05) : 501 - 510
  • [36] Live-Load Testing Application Using a Wireless Sensor System and Finite-Element Model Analysis of an Integral Abutment Concrete Girder Bridge
    Fausett, Robert W.
    Barr, Paul J.
    Halling, Marvin W.
    [J]. JOURNAL OF SENSORS, 2014, 2014
  • [37] Live-load test results of Missouri's first high-performance concrete superstructure bridge
    Yang, YM
    Myers, JJ
    [J]. DESIGN OF STRUCTURES 2003: BRIDGES, OTHER STRUCTURES, AND HYDRAULICS AND HYDROLOGY, 2003, (1845): : 96 - 103
  • [38] Deformation characteristics of main cable in suspension bridge caused by live load
    Chai, Shengbo
    Xiao, Rucheng
    Sun, Bin
    [J]. Tongji Daxue Xuebao/Journal of Tongji University, 2012, 40 (10): : 1452 - 1457
  • [39] System identification of suspension bridge from ambient vibration response
    Siringoringo, Dionysius M.
    Fujino, Yozo
    [J]. ENGINEERING STRUCTURES, 2008, 30 (02) : 462 - 477
  • [40] Static-dynamic load testing of the Nanpanjiang suspension bridge
    Zhong, Y.
    [J]. BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 391 - 395