Measurement of breath acetone concentrations by selected ion flow tube mass spectrometry in type 2 Diabetes

被引:76
|
作者
Storer, Malina [1 ]
Dummer, Jack [2 ]
Lunt, Helen [3 ]
Scotter, Jenny [1 ]
McCartin, Fiona [2 ]
Cook, Julie [2 ]
Swanney, Maureen [2 ]
Kendall, Deborah [3 ]
Logan, Florence [3 ]
Epton, Michael [2 ]
机构
[1] Syft Technol Ltd, Christchurch, New Zealand
[2] Christchurch Hosp, Dept Resp Med, Christchurch, New Zealand
[3] Christchurch Hosp, Ctr Diabet, Christchurch, New Zealand
关键词
BLOOD-GLUCOSE; ANALYZER; AMMONIA; SIFT;
D O I
10.1088/1752-7155/5/4/046011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Selected ion flow tube-mass spectrometry (SIFT-MS) can measure volatile compounds in breath on-line in real time and has the potential to provide accurate breath tests for a number of inflammatory, infectious and metabolic diseases, including diabetes. Breath concentrations of acetone in type 2 diabetic subjects undertaking a long-term dietary modification programme were studied. Acetone concentrations in the breath of 38 subjects with type 2 diabetes were determined by SIFT-MS. Anthropomorphic measurements, dietary intake and medication use were recorded. Blood was analysed for beta hydroxybutyrate (a ketone body), HbA1c (glycated haemoglobin) and glucose using point-of-care capillary (fingerprick) testing. All subjects were able to undertake breath manoeuvres suitable for analysis. Breath acetone varied between 160 and 862 ppb (median 337 ppb) and was significantly higher in men (median 480 ppb versus 296 ppb, p = 0.01). In this cross-sectional study, no association was observed between breath acetone and either dietary macronutrients or point-of-care capillary blood tests. Breath analysis by SIFT-MS offers a rapid, reproducible and easily performed measurement of acetone concentration in ambulatory patients with type 2 diabetes. The high inter-individual variability in breath acetone concentration may limit its usefulness in cross-sectional studies. Breath acetone may nevertheless be useful for monitoring metabolic changes in longitudinal metabolic studies, in a variety of clinical and research settings.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Repeatability of the Measurement of Exhaled Volatile Metabolites Using Selected Ion Flow Tube Mass Spectrometry
    Boshier, Piers R.
    Marczin, Nandor
    Hanna, George B.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (06) : 1070 - 1074
  • [22] Combining Thermal Desorption with Selected Ion Flow Tube Mass Spectrometry for Analyses of Breath Volatile Organic Compounds
    Belluomo, Ilaria
    Whitlock, Sophia E.
    Myridakis, Antonis
    Parker, Aaron G.
    Converso, Valerio
    Perkins, Mark J.
    Langford, Vaughan S.
    Spanel, Patrik
    Hanna, George B.
    ANALYTICAL CHEMISTRY, 2024, 96 (04) : 1397 - 1401
  • [23] Exhaled Breath Analysis Using Selected Ion Flow Tube Mass Spectrometry and Disease Severity in Heart Failure
    Tang, Wai Hong Wilson
    Tranchito, Lily
    Albert, Chonyang
    Gul, Zeynep G.
    Cikach, Frank S.
    Grove, David
    Wu, Yuping
    Dweik, Raed A.
    METABOLITES, 2023, 13 (10)
  • [24] Detection of monobromamine, monochloramine and dichloramine using selected ion flow tube mass spectrometry and their relevance as breath markers
    Senthilmohan, Senti T.
    Kettle, Anthony J.
    McEwan, Murray J.
    Durnmer, Jack
    Edwards, Samuel J.
    Wilson, Paul F.
    Epton, Michael J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (05) : 677 - 681
  • [25] Quantification of volatile metabolites in exhaled breath by selected ion flow tube mass spectrometry, SIFT-MS
    Spanel, Patrik
    Smith, David
    CLINICAL MASS SPECTROMETRY, 2020, 16 : 18 - 24
  • [26] Quantification of breath carbon disulphide and acetone following a single dose of disulfiram (Antabuse) using selected ion flow tube mass spectrometry (SIFT-MS)
    Bloor, Roger N.
    Spanel, Patrick
    Smith, David
    ADDICTION BIOLOGY, 2006, 11 (02) : 163 - 169
  • [27] Alcohol in breath and blood: a selected ion flow tube mass spectrometric study
    Wilson, PF
    Freeman, CG
    McEwan, MJ
    Milligan, DB
    Allardyce, RA
    Shaw, GM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (06) : 413 - 417
  • [28] Selected Ion Flow Tube Mass Spectrometry, SIFT-MS
    Spanel, Patrik
    Smith, David
    CURRENT ANALYTICAL CHEMISTRY, 2013, 9 (04) : 523 - 524
  • [29] Real-time measurement of peroxyacetyl nitrate using selected ion flow tube mass spectrometry
    Hastie, Donald R.
    Gray, John
    Langford, Vaughan S.
    Maclagan, Robert G. A. R.
    Milligan, Daniel B.
    McEwan, Murray J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (03) : 343 - 348
  • [30] Breath Volatile Organic Compound Profiling of Colorectal Cancer Using Selected Ion Flow-tube Mass Spectrometry
    Markar, Sheraz R.
    Chin, Sung-Tong
    Romano, Andrea
    Wiggins, Tom
    Antonowicz, Stefan
    Paraskeva, Paraskevas
    Ziprin, Paul
    Darzi, Ara
    Hanna, George B.
    ANNALS OF SURGERY, 2019, 269 (05) : 903 - 910