The analysis of possibility of applying the FDS technique for moisture evaluation in power transformers with varnish-paper-oil insulation

被引:0
|
作者
Gielniak, Jaroslaw [1 ]
机构
[1] Politechn Poznanska, Inst Elektroenergetyki, PL-60965 Poznan, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2010年 / 86卷 / 11B期
关键词
moisture in insulation; dielectric spectroscopy; power transformer; insulating varnish;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents an analysis of possibility of the FDS technique application for moisture evaluation in power transformers with varnished transposed wires. The power transformer and two types of insulating varnish were investigated. The author concluded that thin layer of varnish doesn't have the significant influence on the dielectric response of transformer insulation. (The analysis of possibility of applying the FDS technique for moisture evaluation in power transformers with varnish-paper-oil insulation).
引用
收藏
页码:217 / 219
页数:3
相关论文
共 50 条
  • [21] DIELECTRIC RESPONSE ANALYSIS AND DIAGNOSIS OF OIL-FILLED POWER TRANSFORMERS Calculation of paper moisture in power transformer
    Singh, Shrikant
    Kumar, Ambuj
    Singh, Sunil Kumar
    Jarial, R. K.
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,
  • [22] A Mathematical Contribution to the Analysis of Moisture Migration in Power Transformer Oil-Paper Insulation Systems
    Marques, A. P.
    Sousa, F. R. de C.
    Brito, L. da C.
    Ribeiro, C. J.
    Azevedo, C. H. B.
    dos Santos, J. A. L.
    2015 IEEE 10TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2015, : 1 - 6
  • [23] Method for Rating and Analyzing the Combined Effects of Moisture and Temperature on the Oil–Paper Insulation System of Power Transformers by Means of Load Variations
    Felipe Resende de Carvalho Sousa
    Cacilda de Jesus Ribeiro
    André Pereira Marques
    Leonardo da Cunha Brito
    Journal of Control, Automation and Electrical Systems, 2020, 31 : 1309 - 1321
  • [24] Evaluation of moisture content in insulation of windings of power transformers with respect to dielectric characteristics
    Vanin B.V.
    L'vov Yu.N.
    L'vov M.Yu.
    Power Technology and Engineering, 2005, 39 (2) : 114 - 116
  • [25] Space charge and its effects on oil-paper insulation in power transformers: A review
    Raj, Raymon Antony
    JOURNAL OF ELECTROSTATICS, 2023, 126
  • [26] Modeling dynamic propagation of characteristic gases in power transformers oil-paper insulation
    Shahsiah, A.
    Degeneff, R. C.
    Nelson, J. K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (03) : 710 - 717
  • [27] FDS Measurement-Based Moisture Estimation Model for Transformer Oil-Paper Insulation Including the Aging Effect
    Fan, Xianhao
    Liu, Jiefeng
    Lai, Benghui
    Zhang, Yiyi
    Zhang, Chaohai
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [28] Study on FDS characteristics of oil-immersed paper insulation bushing under non-uniform moisture content
    Zhang, Daning
    Zhao, Haoxiang
    Yun, Hao
    Liu, Xiaowei
    Han, Yanhua
    Mu, Haibao
    Zhang, Guan-jun
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (05) : 691 - 697
  • [29] Novel Method Using Transformer Moisture Equilibrium for Removal of Absorbed Moisture from Cellulose Paper Insulation in Power Transformers
    Swamynathan K.
    Sthalasayanam N.
    Sridevi M.
    Sudheesh A.K.
    Journal of The Institution of Engineers (India): Series B, 2024, 105 (03) : 503 - 513
  • [30] Frequency Response Analysis as a technique for moisture diagnostics of power transformers
    Yadav, Ramesh
    Venkatasami, A.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 906 - 908