Infrequent physician use of implantable cardioverter-defibrillators risks patient safety

被引:17
|
作者
Lyman, Stephen [1 ]
Sedrakyan, Art [2 ]
Do, Huong [1 ]
Razzano, Renee [2 ]
Mushlin, Alvin I. [2 ]
机构
[1] Hosp Special Surg Epidemiol & Biostat, New York, NY 10021 USA
[2] Weill Cornell Med Coll, Dept Publ Hlth, New York, NY USA
基金
美国医疗保健研究与质量局;
关键词
NONISCHEMIC CARDIOMYOPATHY; PACEMAKER-IMPLANTATION; PROCEDURE VOLUME; COMPLICATIONS; PREVENTION; MORTALITY; ASSOCIATION; OUTCOMES; REPAIR; COST;
D O I
10.1136/hrt.2011.226282
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. Objectives To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Design Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients New York state residents undergoing ICD implantation. Main outcome measures Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. Results This cohort (N = 38 992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) post-implantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-low-volume operators were more likely to die (RR 1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR = 4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. Conclusions These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.
引用
收藏
页码:1655 / 1660
页数:6
相关论文
共 50 条
  • [41] Implantable Cardioverter-Defibrillators in Patients With COPD
    Naksuk, Niyada
    Kunisaki, Ken M.
    Benditt, David G.
    Tholakanahalli, Venkatakrishna
    Adabag, Selcuk
    CHEST, 2013, 144 (03) : 778 - 783
  • [42] IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - A GUIDE FOR CLINICIAN
    DAVIDSON, T
    VANRIPER, S
    HARPER, P
    WENK, A
    HEART & LUNG, 1994, 23 (03): : 205 - 215
  • [43] Implantable cardioverter-defibrillators in dialysis patients
    Mills, Mark T.
    BMJ EVIDENCE-BASED MEDICINE, 2020, 25 (05) : 187 - 188
  • [44] Balancing the risks of adverse events and optimal programming of implantable cardioverter-defibrillators
    Stroobandt, Roland
    Duytschaever, Mattias
    Tavernier, Rene
    EUROPACE, 2020, 22 (01): : 170 - 170
  • [45] IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AND FITNESS TO DRIVE
    PETCH, MC
    LANCET, 1994, 343 (8898): : 674 - 674
  • [46] Implantable cardioverter-defibrillators in tetralogy of Fallot
    Khairy, Paul
    Harris, Louise
    Landzberg, Michael J.
    Viswanathan, Sangeetha
    Barlow, Amanda
    Gatzoulis, Michael A.
    Fernandes, Susan M.
    Beauchesne, Luc
    Therrien, Judith
    Chetaille, Philippe
    Gordon, Elaine
    Muhll, Isabelle Vonder
    Cecchin, Frank
    CIRCULATION, 2008, 117 (03) : 363 - 370
  • [47] HOW USEFUL ARE IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    FOGOROS, RN
    POSTGRADUATE MEDICINE, 1992, 92 (01) : 301 - &
  • [48] Implantable cardioverter-defibrillators and hospice care
    Kirk, Timothy W.
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2007, 26 (04): : 82 - 84
  • [49] Implantable cardioverter-defibrillators and the older patient: the Dutch clinical practice
    Yilmaz, Dilek
    Egorova, Anastasia D.
    Schalij, Martin J.
    van Erven, Lieselot
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2022, 21 (02) : 169 - 173
  • [50] Implantable cardioverter-defibrillators, heart failure, and patient characteristics - Reply
    Hernandez, Adrian F.
    Fonarow, Gregg C.
    Peterson, Eric D.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (03): : 286 - 286