Thermal performance of plate-type loop thermosyphon at sub-atmospheric pressures

被引:22
|
作者
Tsoi, Vadim [2 ]
Chang, Shyy Woei [1 ]
Chiang, Kuei Feng [3 ]
Huang, Chuan Chin [4 ]
机构
[1] Natl Kaohsiung Marine Univ, Thermal Fluids Lab, Kaohsiung 811, Taiwan
[2] Huawei Technol Sweden AB, Elect Cooling Expert, SE-16494 Kista, Sweden
[3] Asia Vital Components Co Ltd, Senior Res Manager CEO Off, Hsin Chuang City 24892, Taipei, Taiwan
[4] Asia Vital Components Co Ltd, R&D Engineer, Hsin Chuang City 24892, Taipei, Taiwan
关键词
Two-phase loop thermosyphon; Low pressure plate type thermosyphon; CLOSED 2-PHASE THERMOSIPHON; PULSATING HEAT PIPES; REFRIGERANTS; FLUX;
D O I
10.1016/j.applthermaleng.2011.04.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
This experimental study examines the thermal performance of a newly devised plate-type two-phase loop thermosyphon with cooling applications to electronic boards of telecommunication systems. The evaporation section is configured as the inter-connected multi channels to emulate the bridging boiling mechanism in pulsating thermosyphon. Two thermosyphon plates using water as the coolant with filling ratios (FR) of 0.22 and 0.32 are tested at sub-atmospheric pressures. The vapor-liquid flow images as well as the thermal resistances and effective spreading thermal conductivities are individually measured for each thermosyphon test plate at various heating powers. The high-speed digital images of the vapor-liquid flow structures reveal the characteristic boiling phenomena and the vapor-liquid circulation in the vertical thermosyphon plate, which assist to explore the thermal physics for this type of loop thermosyphon. The bubble agglomeration and pumping action in the inter-connected boiling channels take place at metastable non-equilibrium conditions, leading to the intermittent slug flows with a pulsation character. Such hybrid loop-pulsating thermosyphon permits the vapor-liquid circulation in the horizontal plate. Thermal resistances and spreading thermal conductivities detected from the present thermosyphon plates; the vapor chamber flat plate heat pipe and the copper plate at free and forced convective cooling conditions with both vertical and horizontal orientations are cross-examined. In most telecommunication systems and units, the electrical boards are vertical so that the thermal performance data on the vertical thermosyphon are most relevant to this particular application. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2556 / 2567
页数:12
相关论文
共 50 条
  • [21] Particle Simulation of Ultrafast Closing Switch at Sub-Atmospheric Pressures
    Chaparro, Jordan
    Krompholz, Hermann
    Neuber, Andreas
    Hatfield, Lynn
    PROCEEDINGS OF THE 2008 IEEE INTERNATIONAL POWER MODULATORS AND HIGH VOLTAGE CONFERENCE, 2008, : 499 - 502
  • [22] HIGH-FREQUENCY DISCHARGES IN KRYPTON AT SUB-ATMOSPHERIC PRESSURES
    PARVAN, R
    BOHATIEL, T
    REVUE ROUMAINE DE PHYSIQUE, 1978, 23 (04): : 317 - 325
  • [23] Simulation of Microgravity Diffusion Flames Using Sub-Atmospheric Pressures
    Panek, Natalie
    Charest, Marc R. J.
    Guelder, Oemer L.
    AIAA JOURNAL, 2012, 50 (04) : 976 - 980
  • [24] Transient and sub-atmospheric performance of a closed-loop electroosmotic microchannel cooling system
    Jiang, L
    Mikkelsen, J
    Koo, JM
    Zhang, L
    Huber, D
    Yao, S
    Bari, A
    Zhou, P
    Santiago, J
    Kenny, T
    Goodson, KE
    Maveety, J
    Prasher, R
    Benning, S
    THERMAL CHALLENGES IN NEXT GENERATION ELECTRONIC SYSTEMS, 2002, : 133 - 139
  • [25] Flow boiling of water in a vertical tube at sub-atmospheric pressures
    Barbosa, Jader R., Jr.
    Cheah, Leong W.
    Hewitt, Geoffrey F.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2007, 29 (04) : 401 - 409
  • [26] Analysis of cycloid type vacuum compressors for water vapor compression systems at sub-atmospheric pressures
    Moesch, T. W.
    Janitschke, T.
    Thomas, C.
    Hesse, U.
    INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS 2019, 2019, 604
  • [27] AIR-OPERATED PRESSURE BALANCE AS A STANDARD FOR SUB-ATMOSPHERIC PRESSURES
    DADSON, RS
    GREIG, RGP
    VACUUM, 1965, 15 (01) : 21 - &
  • [28] Pool Boiling of Liquids & their Mixtures on Enhanced Surfaces at Sub-atmospheric Pressures
    Alam, M. Siraj
    Agarwal, V. K.
    ICHEAP-9: 9TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2009, 17 : 1503 - +
  • [29] Boiling vertical two-phase flow at sub-atmospheric pressures
    Kockum, H
    Jernqvist, A
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (19) : 2909 - 2924
  • [30] Spray-freeze-drying of whey proteins at sub-atmospheric pressures
    Anandharamakrishnan, Chinnaswamy
    Rielly, Chris D.
    Stapley, Andrew G. F.
    DAIRY SCIENCE & TECHNOLOGY, 2010, 90 (2-3) : 321 - 334