Wind-driven stand-alone six-phase self-excited induction generator transients under different loading conditions

被引:3
|
作者
Kumar, A. Senthil [1 ]
Munda, Josiah L. [1 ]
Singh, G. K. [2 ]
机构
[1] Tshwane Univ Technol, Ctr Energy & Elect Power, ZA-0001 Pretoria, South Africa
[2] Indian Inst Technol, Dept Elect Engn, Roorkee 247667, Uttar Pradesh, India
关键词
Wind turbine; Self-excited induction generator; Dynamic analysis; Loading conditions; Voltage regulation; MACHINE;
D O I
10.1007/s00202-014-0318-x
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper present the transient performance of an isolated six-phase self-excited induction generator (SPSEIG) driven by a fixed-pitch wind turbine. The approach is based on a wind-turbine model, SPSEIG model and detailed transient behaviour of an SPSEIG for stand-alone power generation, when subjected to sudden switching of balanced/unbalanced R, RL and RLC load for both three-phase winding sets. The computer model has been developed in an arbitrary reference frame. In the d-q axis model, the effects of common mutual leakage inductance between the two three-phase winding sets have been included. The simulation results show a good performance from the system under different loading conditions. While the interaction between the two windings is inevitable and variation of load at one winding set changes the operating conditions at the other winding, the situation is still satisfactory for a wide range of rural resistive loads.