Micromachined silicon cantilevers with integrated high-frequency magnetoimpedance sensors for simultaneous strain and magnetic field detection

被引:16
|
作者
Buettel, G. [1 ]
Joppich, J. [1 ]
Hartmann, U. [1 ]
机构
[1] Saarland Univ, Inst Expt Phys, D-66041 Saarbrucken, Germany
关键词
THIN-FILM; MULTILAYERS; SENSITIVITY; ANISOTROPY;
D O I
10.1063/1.5003263
中图分类号
O59 [应用物理学];
学科分类号
摘要
Giant magnetoimpedance (GMI) measurements in the high-frequency regime utilizing a coplanar waveguide with an integrated Permalloy multilayer and micromachined on a silicon cantilever are reported. The fabrication process is described in detail. The aspect ratio of the magnetic multilayer in the magnetoresistive and magnetostrictive device was varied. Tensile strain and compressive strain were applied. Vector network analyzer measurements in the range from the skin effect to ferromagnetic resonance confirm the technological potential of GMI-based micro-electro-mechanical devices for strain and magnetic field sensing applications. The strain-impedance gauge factor was quantified by finite element strain calculations and reaches a maximum value of almost 200. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] High-frequency spin-dependent tunnelling in magnetic nanocomposites: Magnetorefractive effect and magnetoimpedance
    Granovsky, A
    Kozlov, A
    Nedukh, S
    Tarapov, S
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 294 (02) : 117 - 121
  • [22] High-Q micromachined three-dimensional integrated inductors for high-frequency applications
    Weon, Dae-Hee
    Jeon, Jong-Hyeok
    Mohammadi, Saeed
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2007, 25 (01): : 264 - 270
  • [23] High-frequency nanostructured magnetic materials for integrated inductors
    McCloskey, Paul
    Jamieson, Brice
    O'Donnell, Terence
    Gardner, Donald
    Morris, Michael A.
    Roy, Saibal
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2008, 320 (20) : 2509 - 2512
  • [24] Advanced integrated magnetic-field sensors with frequency output
    Gumenjuk, S
    Podlepetsky, B
    SENSORS AND ACTUATORS A-PHYSICAL, 1997, 62 (1-3) : 529 - 533
  • [25] Advanced integrated magnetic-field sensors with frequency output
    Moscow Engineering Physics Inst, Moscow, Russia
    Sensors and Actuators, A: Physical, 1997, 62 (1 -3 pt 3): : 529 - 533
  • [26] Biomagnetic field detection using very high sensitivity magnetoimpedance sensors for medical applications
    Uchiyama, Tsuyoshi
    Nakayama, Shinsuke
    Mohri, Kaneo
    Bushida, Kenichi
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2009, 206 (04): : 639 - 643
  • [27] PROTOTYPING CONVENTIONALLY WOUND HIGH-FREQUENCY MAGNETIC SENSORS FOR ITER
    Testa, D.
    Toussaint, M.
    Chavan, R.
    Encheva, A.
    Lister, J. B.
    Moret, J-M.
    Sanchez, F.
    FUSION SCIENCE AND TECHNOLOGY, 2012, 61 (01) : 19 - 50
  • [28] High-frequency impedance of layered conductors in a high magnetic field
    Peschanskii, VG
    Kozlov, IV
    Jiasemides, K
    LOW TEMPERATURE PHYSICS, 2000, 26 (02) : 169 - 170
  • [29] Integrated high-frequency sensors in catheters for minimally invasive plaque characterization
    Guha, Subhajit
    Schumann, Ulrich
    Jamal, Farabi Ibne
    Wagner, David
    Meliani, Chafik
    Schmidt, Bertram
    Wenger, Christian
    Wessel, Jan
    Detert, Markus
    2015 EUROPEAN MICROELECTRONICS PACKAGING CONFERENCE (EMPC), 2015,
  • [30] Integrated Precision High-Frequency Signal Conditioner for Variable Impedance Sensors
    Brkic, Miodrag
    Radic, Jelena
    Babkovic, Kalman
    Damnjanovic, Mirjana
    SENSORS, 2024, 24 (20)