Reliability and criterion validity of two-dimensional movement assessments in those with patellofemoral pain

被引:0
|
作者
Lally, Erin Marie [1 ]
Thorpe, Jennifer [2 ]
Ericksen, Hayley [1 ]
Earl-Boehm, Jennifer [1 ]
机构
[1] Univ Wisconsin, 3409 Downer Ave, Milwaukee, WI 53211 USA
[2] Concordia Univ, 12800 N Lake Shore Dr, Mequon, WI 53097 USA
关键词
Measurement properties; Movement assessment; Frontal plane projection angle; Dynamic valgus index; PLANE PROJECTION ANGLE; DYNAMIC VALGUS; HIP KINEMATICS; FEMALES; INTERRATER; MECHANICS; UTILITY; TRUNK; WOMEN;
D O I
10.1016/j.ptsp.2022.10.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: Determine criterion validity and intra/inter-rater reliability of 2-dimensional (2D) knee frontal plane projection angle (kFPPA), hip frontal plane projection angle (hFPPA), and dynamic valgus index (DVI) during forward step-downs in those with patellofemoral pain (PFP).Design: Cross-sectional.Setting: University research laboratory.Participants: 39 participants with PFP (34.18 +/- 7.41years, 170 +/- .1 cm, 81.03 +/- 19.36 kg, duration of pain: 68.67 +/- 85.08months, anterior knee pain scale: 80.49 +/- 7.87, visual analog scale:2.08 +/- 2.02)Main outcome measures: Average 3D hip and knee sagittal, frontal, and transverse joint angles and 2D kFPPA, hFPPA, and DVI at maximum knee flexion were variables of interest. 3D DVI was calculated as the sum of hip and knee frontal and transverse angles. 2D kFPPA, hFPPA, and DVI were calculated by two raters independently on two occasions.Results: Intra-and inter-rater reliability of all 2D angles were excellent. kFPPA was moderately correlated to 3D knee transverse angles. hFPPA was moderately correlated to 3D hip frontal and transverse angles and largely correlated to 3D DVI. 2D DVI was moderately correlated to hip transverse angles.Conclusion: kFPPA, hFPPA, and DVI are reliable. hFPPA may be reflective of 3D hip and knee frontal and transverse motion during forward step-downs in those with PFP.Published by Elsevier Ltd.
引用
收藏
页码:134 / 140
页数:7
相关论文
共 50 条
  • [41] A Study on Reliability of a Special Two-dimensional System
    Zhao, Xian
    He, Aimin
    Cui, Lirong
    Liu, Fen
    2009 IEEE 16TH INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1 AND 2, PROCEEDINGS, 2009, : 1165 - 1168
  • [42] Validity and Reliability of Two-Dimensional Motion Analysis for Quantifying Postural Deficits in Adults With and Without Neurological Impairment
    Paul, S. S.
    Lester, M. E.
    Foreman, K. B.
    Dibble, L. E.
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2016, 299 (09): : 1165 - 1173
  • [43] Reliability of a two-dimensional footprint measurement approach
    Reel, Sarah
    Rouse, Simon
    Vernon, Wesley
    Doherty, Patrick
    SCIENCE & JUSTICE, 2010, 50 (03) : 113 - 118
  • [44] Reliability and validity of two-dimensional motion capture to assess ankle dorsiflexion motion and heel raise work
    Dao, Megan
    Mosby, Hadley
    Westphalen, Emma
    Post, Andrew A.
    Wilken, Jason M.
    Netto, Cesar de Cesar
    Hall, Mederic M.
    Danielson, Jessica
    Sluka, Kathleen A.
    Chimenti, Ruth L.
    PHYSICAL THERAPY IN SPORT, 2023, 62 : 10 - 16
  • [45] Two-Dimensional Software Reliability Measurement Technologies
    Inoue, Shinji
    Yamada, Shigeru
    2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1-4, 2009, : 223 - 227
  • [46] Validity of the ADM formulation in two-dimensional quantum gravity
    Ghoroku, K
    Kaneko, K
    PHYSICAL REVIEW D, 1996, 53 (12): : 6960 - 6965
  • [47] OSCILLATION CRITERION FOR TWO-DIMENSIONAL DYNAMIC SYSTEMS ON TIME SCALES
    Hassan, Taher S.
    TAMKANG JOURNAL OF MATHEMATICS, 2013, 44 (03): : 227 - 232
  • [48] An exact criterion for the stirring properties of nearly two-dimensional turbulence
    Hua, BL
    Klein, P
    PHYSICA D, 1998, 113 (01): : 98 - 110
  • [50] A stability criterion for a two-dimensional finite-difference scheme
    Gulin, AV
    Degtyarev, SL
    DIFFERENTIAL EQUATIONS, 1996, 32 (07) : 950 - 957