Thermodynamic study on thermal insulation schemes for liquid helium storage tank

被引:14
|
作者
Zhang, Caigong [1 ]
Li, Changjun [1 ,2 ]
Jia, Wenlong [1 ,2 ]
Pang, Yu [1 ]
机构
[1] Southwest Petr Univ, Petr Engn Sch, Chengdu 610500, Sichuan, Peoples R China
[2] Southwest Petr Univ, CNPC Key Lab Oil & Gas Storage & Transportat, Chengdu 610500, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid helium tank; Thermal insulation schemes; Thermodynamic model; Variable density configuration; Self-evaporation vapor cooled shield; DENSITY MULTILAYER INSULATION; VAPOR-COOLED SHIELD; COMPOSITE INSULATION; HEAT-TRANSFER; OPTIMIZATION; PERFORMANCE; HYDROGEN; SYSTEM; FOAM; STRATIFICATION;
D O I
10.1016/j.applthermaleng.2021.117185
中图分类号
O414.1 [热力学];
学科分类号
摘要
The temperature of liquid helium (LHe) is 4.2 K, high-performance thermal insulation schemes such as the variable density (VD) and self-evaporation vapor-cooled shield (VCS) are required for LHe tank. However, the working parameters of the VD and VCS in LHe tank have not been investigated. However, the related researches on liquid hydrogen tank neglected the heat transfer of the tank wall and the gap; The VD configuration may less than the optimal because the maximum number of spacers for each layer was pre-set artificially. Meanwhile, the recovery rate of sensible heat cannot be obtained by the existing model. In this work, these limitations are taken into account to establish the thermodynamic model of composite multilayer insulation (FMLI), VD and VCS, respectively. The results show that the correction coefficient of FMLI model is 0.1875; The layer densities of composite variable density MLI (FVD-MLI) with four segments are 3.31, 6.62, 13.23, and 19.98 layer/cm, with a 9.6% reduction in heat leakage compared to that of FMLI. The optimal position of the VCS in VCS-composited MLI (FMLI + VCS) and VCS-composited variable density MLI (FVD-MLI + VCS) is approximately 30% and 25% near the cold boundary respectively, and 36.2% and 40.7% reduction in heat leakage compared to that of FMLI and FVD-MLI respectively. The VD and VCS promote each other in improving thermal insulation performance, while the VCS plays a greater role than VD.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Study of thermal performance of novel heat storage water tank
    Liao, Chengjun
    Wang, Jinfu
    Yang, Wen
    He, Jiachao
    Leng, Tianjiu
    Yang, Peizhi
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2014, 35 (12): : 2504 - 2507
  • [42] Numerical simulation on the thermal dynamic behavior of liquid hydrogen in a storage tank for trailers
    Li, Shihao
    Yan, Yan
    Wei, Wei
    Zhao, Wang
    Ni, Zhonghua
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 40
  • [43] EXCITATIONS IN LIQUID HELIUM - THERMODYNAMIC CALCULATIONS
    BENDT, PJ
    COWAN, RD
    YARNELL, JL
    PHYSICAL REVIEW, 1959, 113 (06): : 1386 - 1395
  • [44] Evaluation of Thermal Conductivity and Heat Flux by Insulation Analysis of Double-Wall for Cryogenic Storage Tank
    Jeong, Jae-Hyun
    Choi, Dong-Jun
    Won, Jong-Pil
    Park, Dong-Hyun
    Lee, Sung-Yul
    Lee, Myeong-Hoon
    Kim, Yun-Hae
    Moon, Kyung-Man
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 943 - +
  • [45] Analysis and optimization of thermal storage performance of single tank thermocline layer with built-in insulation board
    Xu, Xiaoyu
    Chang, Chun
    Dong, Jiangshuo
    Guo, Xinxin
    He, Mingfei
    Yu, Qiang
    JOURNAL OF ENERGY STORAGE, 2024, 97
  • [46] Numerical simulation of thermal-structural behaviour of liquid helium tank during filling process
    Zhang, Chuanjia
    Zhang, Qiyong
    Zhu, Zhigang
    Yao, Damao
    Yang, Pengcheng
    Zong, Yiwen
    Chen, Shixiong
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [47] Control Strategy Optimization of Thermodynamic Venting System in Liquid Hydrogen Storage Tank Under Microgravity
    Hui Chen
    Xiaolong Li
    Haomai Zhang
    Peng Yang
    Yingwen Liu
    Wenlian Ye
    Chunjie Yan
    Xiaojun Wang
    Yang, Peng (yp2019@mail.xjtu.edu.cn); Wang, Xiaojun (rainer163@163.com), 2025, 37 (01)
  • [48] Numerical investigation on full thermodynamic venting process of liquid hydrogen in an on-orbit storage tank
    Zuo, Zhongqi
    Jiang, WenBing
    Qin, Xujin
    Huang, Yonghua
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (51) : 27792 - 27805
  • [49] Strength Analysis and Reinforcement of 120 m3 Liquid Helium Storage Tank for Transportation Case
    Zhang, Jianguo
    Li, Chao
    Liu, Fa'an
    Xu, Jing
    Liu, Qinghua
    Ma, Shuhui
    Li, Changjun
    Jia, Wenlong
    Li, Longjiang
    PROCESSES, 2025, 13 (01)
  • [50] Thermal characteristics of a solar tank with aerogel surface insulation
    Kamiuto, K
    Miyamoto, T
    Saitoh, S
    APPLIED ENERGY, 1999, 62 (03) : 113 - 123