Repeatability and comparison of clinical techniques for anterior chamber angle assessment

被引:31
|
作者
Campbell, Peter [1 ,2 ,3 ]
Redmond, Tony [2 ,4 ]
Agarwal, Rishi [2 ,3 ]
Marshall, Lewis R. [5 ]
Evans, Bruce J. W. [2 ,3 ,5 ]
机构
[1] St Thomas Hosp, Ophthalmol, London, England
[2] Neville Chappell Res Clin, Inst Optometry, London, England
[3] London S Bank Univ, Fac Hlth & Social Care, London, England
[4] Cardiff Univ, Sch Optometry & Vis Sci, Cardiff CF10 3AX, S Glam, Wales
[5] Cole Martin Tregaskis Optometrists, Brentwood, Essex, England
关键词
anterior chamber; anterior segment; anterior segment optical coherence tomography; Gonioscopy; imaging; Van Herick; OPTICAL COHERENCE TOMOGRAPHY; CLOSURE GLAUCOMA; UK OPTOMETRISTS; NARROW ANGLES; SEGMENT; POPULATION; GONIOSCOPY; AGREEMENT;
D O I
10.1111/opo.12200
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo assess the repeatability of gonioscopy, van Herick method and anterior segment Optical Coherence Tomography (AS-OCT) and determine the agreement between these techniques within a community optometry setting. MethodsGonioscopy, van Herick method and AS-OCT imaging were performed by an optometrist on two occasions, 1month apart, on 80 subjects aged over 40years recruited from community optometry practices. Anterior segment images were captured with a spectral domain OCT (Topcon 3D OCT-2000; wavelength 840nm) set to the Anterior Segment (AS) mode. Eyes were graded as open or occludable for each method. AS-OCT images from both visits were graded by a second optometrist masked to the gonioscopy and van Herick method results, and the visit on which the images were acquired. Cohen's kappa () was used to describe the intra-observer repeatability. Likelihood ratios, sensitivity and specificity of van Herick method and AS-OCT were calculated, using gonioscopy as the reference standard. ResultsMeasurements were obtained from 80 eyes of 80 subjects. In four cases, AS-OCT images were un-gradable due to difficulty in locating the scleral spur. The repeatability of gonioscopy was fair =0.29, while that of the van Herick method (=0.54) and AS-OCT (=0.47) were somewhat better. The van Herick method showed good sensitivity (visit 1: 75%, visit 2: 69%) and high specificity (visit 1: 88%, visit 2: 96%). The sensitivity of AS-OCT was fair (visit 1: 46%, visit 2: 25%), but specificity was high (visit 1: 87%. visit 2: 89%). ConclusionIntra-observer repeatability was better for van Herick method and for AS-OCT than for gonioscopy, despite the latter being considered the gold standard method. The van Herick method appeared to be more sensitive than AS-OCT when identifying eyes at risk of angle closure. A standalone anterior segment OCT with a longer wavelength laser could afford better visualisation of the angle, and might therefore be expected to enable the examiner to make more precise classifications. These instruments are not widely used by optometrists in clinical practice in the UK at present.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 50 条
  • [1] Repeatability and Comparison of Anterior Chamber Angle Assessment Tests
    Campbell, Peter
    Agarwal, Rishi
    Redmond, Tony
    Lim, K. Sheng
    Evans, Bruce
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [2] Anterior chamber angle assessment techniques
    Friedman, David S.
    He, Mingguang
    [J]. SURVEY OF OPHTHALMOLOGY, 2008, 53 (03) : 250 - 273
  • [3] Anterior Chamber Angle Assessment Techniques: A Review
    Riva, Ivano
    Micheletti, Eleonora
    Oddone, Francesco
    Bruttini, Carlo
    Montescani, Silvia
    De Angelis, Giovanni
    Rovati, Luigi
    Weinreb, Robert N.
    Quaranta, Luciano
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 25
  • [4] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [5] Assessment and Comparison of Anterior Chamber Dimensions Using Various Imaging Techniques
    Dinc, Umut Asli
    Oncel, Banu
    Gorgun, Ebru
    Yenerel, Melda Nursal
    Alimgil, Levent
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (01) : 115 - 122
  • [6] Clinical assessment of anterior chamber depth
    Barrett, BT
    McGraw, PV
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1998, 18 : S32 - S39
  • [7] Comparison of Different Modes in Optical Coherence Tomography and Ultrasound Biomicroscopy in Anterior Chamber Angle Assessment
    Wang, Dandan
    Pekmezci, Melike
    Basham, Ryan P.
    He, Mingguang
    Seider, Michael I.
    Lin, Shan C.
    [J]. JOURNAL OF GLAUCOMA, 2009, 18 (06) : 472 - 478
  • [8] Anterior chamber angles in normal Chinese: A comparison of Ultrasound Biomicroscopy, Scheimpflug and gonioscopic angle assessment
    Gazzard, GM
    Friedman, DS
    Foster, P
    Chan, BM
    Devereux, J
    Broman, A
    Quigley, H
    Tielsch, J
    Seah, S
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U455 - U455
  • [9] Repeatability, reproducibility, agreement characteristics of 2 SD-OCT devices for anterior chamber angle
    Akil, Handan
    Dastiridou, Anna
    Marion, Kenneth
    Francis, Brian
    Chopra, Vikas
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2017, 52 (02): : 166 - 170
  • [10] Anterior Chamber Angle Assessment Using Gonioscopy and Ultrasound Biomicroscopy
    Arun Narayanaswamy
    Lingam Vijaya
    B. Shantha
    Mani Baskaran
    A.V. Sathidevi
    Sukumar Baluswamy
    [J]. Japanese Journal of Ophthalmology, 2004, 48 : 44 - 49