SEMI-AUTOMATIC POSITIONING OF THE PROTECTIVE SCREEN BASED ON INTEGRATION WITH A C-ARM X-RAY DEVICE

被引:8
|
作者
Antic, Vojislav M. [1 ]
机构
[1] Univ Clin Ctr Serbia, Belgrade, Serbia
来源
关键词
protective screen; X-ray device; integration; semi-automatic positioning; occupational dose assessment; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; EYE LENS; MONTE-CARLO; CARDIOLOGY; PATIENT; STAFF; EFFICACY;
D O I
10.2298/NTRP201210002A
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In fluoroscopy guided interventional procedures, a ceiling suspended screen is used to protect personnel for scattered X-ray radiation arising from patient treatment. The correct positioning of the screen is crucial for proper occupational radiation protection. The proposed solution in this paper provides reliable and efficient protection from scattered radiation, based on an X-ray device and the protective screen merging into one system via an appropriate interface. After the initial manual positioning, automatic repositioning of the screen is executed, by curving the screen laterally, clockwise or counterclockwise, and then with the upper or lower edge forward. All potential clinical situations were analyzed, considering the need for screen position correction: the semi-automatic solution is designed and realized to follow medical procedure in order to maintain an efficient level of staff radiation protection. Furthermore, the assessment of the occupational radiation dose, provided for screen position optimization, will be included into the radiation dose structural report. With application of the universal interface, the presented solution can be applied not only to newly manufactured ones, but to existing C-arm X-ray devices as well.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [31] Semi-Automatic Terminology Generation for Information Extraction from German Chest X-Ray Reports
    Krebs, Jonathan
    Corovic, Hamo
    Dietrich, Georg
    Ertl, Max
    Fette, Georg
    Kaspar, Mathias
    Krug, Markus
    Stoerk, Stefan
    Puppe, Frank
    [J]. GERMAN MEDICAL DATA SCIENCES: VISIONS AND BRIDGES, 2017, 243 : 80 - 84
  • [32] Semi-Automatic Detection of Cervical Vertebrae in X-ray Images Using Generalized Hough Transform
    Larhmam, Mohamed Amine
    Mahmoudi, Said
    Benjelloun, Mohammed
    [J]. 2012 3RD INTERNATIONAL CONFERENCE ON IMAGE PROCESSING THEORY, TOOLS AND APPLICATIONS, 2012, : 396 - 401
  • [33] Distortion Correction, Geometric Calibration, and Volume Reconstruction for an Isocentric C-Arm X-Ray System
    Mennessier, C.
    Spencer, B.
    Clackdoyle, R.
    Conneau, A-C.
    Xu, T.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2943 - 2947
  • [34] Error Analysis of the X-ray Projection Geometry of Camera-Augmented Mobile C-arm
    Chen, Xin
    Wang, Lejing
    Fallavollita, Pascal
    Navab, Nassir
    [J]. MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [35] Single-camera visual odometry to track a surgical X-ray C-arm base
    Esfandiari, Hooman
    Lichti, Derek
    Anglin, Carolyn
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (12) : 1140 - 1151
  • [36] Super-global distortion correction for a rotational C-arm x-ray image intensifier
    Liu, RR
    Rudin, S
    Bednarek, DR
    [J]. MEDICAL PHYSICS, 1999, 26 (09) : 1802 - 1810
  • [37] High-resolution volume imaging on conventional interventional C-arm X-ray systems
    Rasche, V
    Graeff, C
    Istel, T
    Koppe, R
    Schreiber, B
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1250 - 1250
  • [38] ECG-Gated CT Reconstruction for a C-Arm Inverse Geometry X-Ray System
    Slagowski, J. M.
    Dunkerley, D. A. P.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3701 - 3701
  • [39] Super-global distortion correction for a rotational C-arm x-ray image intensifier
    Toshiba Stroke Research Center, Departments of Physics and Radiology, State University of New York at Buffalo, Buffalo, NY 14214, United States
    不详
    [J]. Med. Phys, 9 (1802-1810):
  • [40] Photogrammetric calibration of a C-arm X-ray system as a verification tool for orthopaedic navigation systems
    Broers, H
    Hemken, H
    Luhmann, T
    Ritschl, P
    [J]. ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2002, 56 (5-6) : 338 - 346