Real-time monitoring of cardiac regional function using FastHARP MRI and region-of-interest reconstruction

被引:9
|
作者
Abd-Elmoniem, Khaled Z. [1 ]
Sampath, Smita
Osman, Nael F.
Prince, Jerry L.
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Image Anal & Commun Lab, Baltimore, MD 21218 USA
[4] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21205 USA
关键词
cardiac motion; FastHARP (HARP-MRI); harmonic phase (HARP); magnetic resonance (MR) tagging; myocardial strain; real-time imaging;
D O I
10.1109/TBME.2007.891946
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiovascular stress test imaging assists in the diagnosis and monitoring of cardiovascular disease. The procedure can be carried out in a magnetic resonance (MR) scanner using pharmacological agents that mimic the effects of natural exercise. In order to provide real time indication of ischemia, thereby assisting in diagnosis and helping to assure patient safety, it is desirable to have real time monitoring of the myocardial regional function. This paper presents an algorithm for the real time myocardium region-of-interest reconstruction and myocardial strain computation using data acquired from a real time pulse sequence that has been previously reported. The chirp Fourier transform is used for efficient computation, enabling a real-time continuous strain map at a rate of 25 frames/s. Coupled with a real time data path from the scanner to a laptop computer, this algorithm enables real time continuous monitoring of cardiac strain and is targeted for use in the early detection and quantification of ischemia during MR stress tests.
引用
收藏
页码:1650 / 1656
页数:7
相关论文
共 50 条
  • [21] A Dynamic Region-of-Interest Vision Tracking System Applied to the Real-Time Wing Kinematic Analysis of Tethered Drosophila
    Graetzel, Chauncey F.
    Nelson, Bradley J.
    Fry, Steven N.
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2010, 7 (03) : 463 - 473
  • [22] Region-of-Interest CT Reconstruction Using Object Extent and Singular Value Decomposition
    Coussat, Aurelien
    Rit, Simon
    Clackdoyle, Rolf
    Defrise, Michel
    Desbat, Laurent
    Letang, Jean Michel
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (05) : 537 - 551
  • [23] Block Region of Interest Method for Real-Time Implementation of Large and Scalable Image Reconstruction
    Li, Lin
    Yu, Feng
    IEEE SIGNAL PROCESSING LETTERS, 2015, 22 (11) : 1908 - 1912
  • [24] ROBUST AND STABLE REGION-OF-INTEREST TOMOGRAPHIC RECONSTRUCTION USING A ROBUST WIDTH PRIOR
    Goossens, Bart
    Labate, Demetrio
    Bodmann, Bernhard G.
    INVERSE PROBLEMS AND IMAGING, 2020, 14 (02) : 291 - 316
  • [25] Interior region-of-interest reconstruction using a small, nearly piecewise constant subregion
    Taguchi, Katsuyuki
    Xu, Jingyan
    Srivastava, Somesh
    Tsui, Benjamin M. W.
    Cammin, Jochen
    Tang, Qiulin
    MEDICAL PHYSICS, 2011, 38 (03) : 1307 - 1312
  • [26] Iterative Region-of-Interest Reconstruction from Limited Data Using Prior Information
    Vogelgesang J.
    Schorr C.
    Sensing and Imaging, 2017, 18 (1):
  • [27] MRI Reconstruction using Real-Time Motion Tracking: A Simulation Study
    Orchard, Jeff
    Staruch, Robert
    2008 42ND ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS, VOLS 1-4, 2008, : 1910 - +
  • [28] Mobile Targets Region-of-Interest via Distributed Pyroelectric Sensor Network: Towards a Robust, Real-time Context Reasoning
    Hu, Fei
    Sun, Qingquan
    Hao, Qi
    2010 IEEE SENSORS, 2010, : 1832 - 1836
  • [29] Real-time MRI Guidance of Cardiac Interventions
    Campbell-Washburn, Adrienne E.
    Tavallaei, Mohammad A.
    Pop, Mihaela
    Grant, Elena K.
    Chubb, Henry
    Rhode, Kawal
    Wright, Graham A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (04) : 935 - 950
  • [30] Real-time cardiac MRI at 3 tesla
    Nayak, KS
    Cunningham, CH
    Santos, JM
    Pauly, JM
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 655 - 660