Confocal total-internal-reflection fluorescence microscopy with a high-aperture parabolic mirror lens

被引:30
|
作者
Ruckstuhl, T [1 ]
Seeger, S [1 ]
机构
[1] Univ Zurich, Inst Chem Phys, CH-8057 Zurich, Switzerland
关键词
D O I
10.1364/AO.42.003277
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a theoretical study of a new total-internal-reflection fluorescence microscope for the detection of fluorescence at a water- glass interface. The system is designed for confocal imaging and spectroscopy of nanoparticles and single molecules. Focusing and fluorescence collection through standard glass coverslips is accomplished by a parabolic mirror lens. The large aperture of the element is used to excite fluorescence within the evanescent field of a diffraction-limited focus and to collect focal emission with high efficiency. Tight focusing and supercritical excitation reduce the detection volume for fluorescent analyte molecules well below that of an attoliter (10(-18) L), which can be advantageous for monitoring surface binding of single molecules without interference from fluorescence of the unbound bulk. Calculations of the electric fields in the focus region and simulated confocal imaging demonstrate the performance of the system. (C) 2003 Optical Society of America.
引用
收藏
页码:3277 / 3283
页数:7
相关论文
共 50 条
  • [31] Characteristics of Collimating Illumination System with Extended Source Based on Total-Internal-Reflection Lens
    Kang Xueliang
    Shi Chengxiang
    Wang Li
    Liu Qilong
    Xue Rui
    Ren Tingting
    Sun Weikang
    Wei Xiantao
    LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (21)
  • [32] Slope error tolerance analysis for Candela distribution of Total-internal-reflection collimating lens
    Luo, Tao
    Wang, Gang
    OPTICAL DESIGN AND TESTING VII, 2016, 10021
  • [33] APPLICATIONS OF TOTAL INTERNAL-REFLECTION FLUORESCENCE MICROSCOPY
    AXELROD, D
    STOUT, AL
    MCKIERNAN, AE
    WANG, MD
    BIOPHYSICAL JOURNAL, 1994, 66 (02) : A251 - A251
  • [34] Total internal reflection fluorescence microscopy in cell biology
    Axelrod, D
    TRAFFIC, 2001, 2 (11) : 764 - 774
  • [35] Total internal reflection fluorescence microscopy in cell biology
    Axelrod, D
    BIOPHOTONICS, PT B, 2003, 361 : 1 - 33
  • [36] Detection efficiency in total internal reflection fluorescence microscopy
    Leutenegger, Marcel
    Lasser, Theo
    OPTICS EXPRESS, 2008, 16 (12) : 8519 - 8531
  • [37] Image processing in total internal reflection fluorescence microscopy
    Kuznetsova, O. B.
    Savchenko, E. A.
    Andryakov, A. A.
    Savchenko, E. Y.
    Musakulova, Z. A.
    INTERNATIONAL CONFERENCE EMERGING TRENDS IN APPLIED AND COMPUTATIONAL PHYSICS 2019 (ETACP-2019), 2019, 1236
  • [38] A mirror-based 2D isotropic illumination in total internal reflection fluorescence microscopy
    Yaghoubi, Sarina
    Sajad, Batool
    Tavaddod, Sharareh
    OPTICS CONTINUUM, 2023, 2 (07): : 1616 - 1624
  • [39] Investigation of cell adhesion to structured surfaces using total internal reflection fluorescence and confocal laser scanning microscopy
    Joos, U
    Biskup, T
    Ernst, O
    Westphal, I
    Gherasim, C
    Schmidt, R
    Edinger, K
    Pilarczyk, G
    Duschl, C
    EUROPEAN JOURNAL OF CELL BIOLOGY, 2006, 85 (3-4) : 225 - 228
  • [40] Imaging stimulated exocytosis with total internal reflection fluorescence microscopy
    Allersma, MW
    Holz, RW
    Axelrod, D
    BIOPHYSICAL JOURNAL, 2002, 82 (01) : 614A - 615A