Gaining insight into the T2*-T2 relationship in surface NMR free-induction decay measurements

被引:6
|
作者
Grombacher, Denys [1 ]
Auken, Esben [1 ]
机构
[1] Aarhus Univ, Geosci Dept, Hydrogeophys Grp, DK-8000 Aarhus, Denmark
关键词
Hydrogeophysics; NUCLEAR-MAGNETIC-RESONANCE; INVERSION; ROCKS;
D O I
10.1093/gji/ggy067
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
One of the primary shortcomings of the surface nuclear magnetic resonance (NMR) free-induction decay (FID) measurement is the uncertainty surrounding which mechanism controls the signal's time dependence. Ideally, the FID-estimated relaxation time T-2* that describes the signal's decay carries an intimate link to the geometry of the pore space. In this limit the parameter T-2* is closely linked to a related parameter T-2, which is more closely linked to pore-geometry. If T-2* similar or equal to T-2 the FID can provide valuable insight into relative pore-size and can be used to make quantitative permeability estimates. However, given only FID measurements it is difficult to determine whether T-2* is linked to pore geometry or whether it has been strongly influenced by background magnetic field inhomogeneity. If the link between an observed T-2* and the underlying T-2 could be further constrained the utility of the standard surface NMR FID measurement would be greatly improved. We hypothesize that an approach employing an updated surface NMR forward model that solves the full Bloch equations with appropriately weighted relaxation terms can be used to help constrain the T-2*-T-2 relationship. Weighting the relaxation terms requires estimating the poorly constrained parameters T-2 and T-1; to deal with this uncertainty we propose to conduct a parameter search involving multiple inversions that employ a suite of forward models each describing a distinct but plausible T-2*-T-2 relationship. We hypothesize that forward models given poor T-2 estimates will produce poor data fits when using the complex-inversion, while forward models given reliable T-2 estimates will produce satisfactory data fits. By examining the data fits produced by the suite of plausible forward models, the likely T-2*-T-2 can be constrained by identifying the range of T-2 estimates that produce reliable data fits. Synthetic and field results are presented to investigate the feasibility of the proposed technique.
引用
收藏
页码:1402 / 1411
页数:10
相关论文
共 50 条
  • [21] Understanding NMR T2 spectral uncertainty
    Prange, Michael
    Song, Yi-Qiao
    JOURNAL OF MAGNETIC RESONANCE, 2010, 204 (01) : 118 - 123
  • [22] Robust myocardial T2 and T2* mapping at 3T
    Arshad Zaman
    David M Higgins
    Marc Kouwenhoven
    Ananth Kidambi
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [23] (T2,T1/T2)Two-DimensionalNMRMethodforGasLayersTyping
    XIE RanhongXIAO LizhiState Key Laboratory of Petroleum Resource and ProspectingChina University of PetroleumBeijing ChinaKey Laboratory of Earth Prospecting and Information TechnologyChina University of PetroleumBeijing China
    测井技术, 2010, 34 (02) : 115 - 119
  • [24] The relationship between the BOLD-induced T2 and T2*:: A theoretical approach for the vasculature of myocardium
    Bauer, WR
    Nadler, W
    Bock, M
    Schad, LR
    Wacker, C
    Hartlep, A
    Ertl, G
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (06) : 1004 - 1010
  • [25] The Relationship among Cardiac T2*, Liver T2*and Abnormal Glucose in Patients with Thalassemia Major
    Lao, Wenqin
    Lliang, Liyang
    Meng, Zhe
    Ou, Hui
    Liu, Zulin
    HORMONE RESEARCH IN PAEDIATRICS, 2016, 86 : 249 - 250
  • [26] T2 and T2* mapping and weighted imaging in cardiac MRI
    Topriceanu, Constantin-Cristian
    Pierce, Iain
    Moon, James C.
    Captur, Gabriella
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 15 - 32
  • [27] REPLY T2 versus T2*: competitive or complementary sequences?
    Betgem, Ryanne P.
    de Waard, Guus A.
    Nijveldt, Robin
    Beek, Aernout M.
    Escaned, Javier
    van Royen, Niels
    NATURE REVIEWS CARDIOLOGY, 2015, 12 (04) : 198 - 198
  • [28] Measuring liver T2*and cardiac T2*in a single acquisition
    Serai, Suraj D.
    Trout, Andrew T.
    Fleck, Robert J.
    Quinn, Charles T.
    Dillman, Jonathan R.
    ABDOMINAL RADIOLOGY, 2018, 43 (09) : 2303 - 2308
  • [29] A characterization of the semipartial geometries T2*(U) and T2*(B)
    De Clerck, F
    De Winter, S
    Thas, JA
    EUROPEAN JOURNAL OF COMBINATORICS, 2004, 25 (01) : 73 - 85
  • [30] T2 relaxation time measurements in osteoarthritis
    David-Vaudey, E
    Ghosh, S
    Ries, M
    Majumdar, S
    MAGNETIC RESONANCE IMAGING, 2004, 22 (05) : 673 - 682