High-Frequency Ultrasound Imaging With Sub-Nyquist Sampling

被引:6
|
作者
Kang, Jinbum [1 ]
Yoon, Heechul [2 ]
Yoon, Changhan [3 ]
Emelianov, Stanislav Y. [4 ,5 ,6 ]
机构
[1] Univ Washington, Dept Bioengn, UWAMIT Ctr, Seattle, WA 98105 USA
[2] Dankook Univ, Sch Elect & Elect Engn, Yongin 16890, South Korea
[3] Inje Univ, Dept Biomed Engn, Gimhae 50834, South Korea
[4] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[5] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[6] Emory Univ, Sch Med, Atlanta, GA 30332 USA
基金
新加坡国家研究基金会; 美国国家卫生研究院;
关键词
Bandpass sampling; computational complexity; high-frequency ultrasound (HFUS); postfiltering-based beamformer; BEAMFORMER ARCHITECTURE; MICRO-ULTRASOUND; ARRAY; TRANSDUCERS; SYSTEM;
D O I
10.1109/TUFFC.2022.3167726
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Implementation of a high-frequency ultrasound (HFUS) beamformer is computationally challenging because of its high sampling rate. This article introduces an efficient beamformer with sub-Nyquist sampling (or bandpass sampling) that is suitable for HFUS imaging. Our approach used channel radio frequency data sampled at bandpass sampling rate (i.e., 4/3f(c)) and postfiltering-based interpolation to reduce the computational complexity. A polyphase structure for interpolation was used to further reduce the computational burden while maintaining an adequate delay resolution (delta). The performance of the proposed beamformer (i.e., 4/3f(c) sampling with sixfold interpolation, delta = 8f(c)) was compared with that of the conventional method (i.e., 4f(c) sampling with fourfold interpolation, delta = 16f(c)). Ultrafast coherent compounding imaging was used in simulation, in vitro and in vivo imaging experiments. Axial/lateral resolution and contrast-to-noise ratio (CNR) values were measured for quantitative evaluation. The number of transmit pulse cycles was varied from 1 to 3 using two transducers with different fractional bandwidths (67% and 98%). In the simulation, the proposed and conventional methods showed the similar -6-dB axial beam widths (63.5 and 61.5 mu m, respectively) from the two-cycle transmit pulse using the transducer with a bandwidth of 67%. In vitro and in vivo imaging experiments were performed using a Verasonics ultrasound research platform equipped with a high-frequency array transducer (20-46 MHz). The in vitro imaging results using a wire target showed consistent results with the simulation study (i.e., disparity 5 mu m at -6-dB axial resolution). The in vivo feasibility study with a murine mouse model with breast cancer was also performed, and the proposed method yielded a similar image quality compared with the conventional method. From these studies, it was demonstrated that the proposed HFUS beamformer based on the bandpass sampling can substantially reduce the computational complexity while minimizing the loss of spatial resolution for HFUS imaging.
引用
收藏
页码:2001 / 2009
页数:9
相关论文
共 50 条
  • [41] Frequency-Selective Signal Sensing with Sub-Nyquist Uniform Sampling Scheme
    Pierzchlewski, Jacek
    Arildsen, Thomas
    2015 12TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON SENSING, COMMUNICATION, AND NETWORKING (SECON), 2015, : 166 - 168
  • [42] SUB-NYQUIST SAMPLING PROCESS IN PRESENCE OF NOISY SAMPLING SIGNAL
    SARHADI, M
    AITCHISON, CS
    ELECTRONICS LETTERS, 1980, 16 (10) : 350 - 352
  • [43] Joint DOA and Frequency Estimation With Sub-Nyquist Sampling in the Sparse Array System
    Liu, Liang
    Wei, Ping
    IEEE SIGNAL PROCESSING LETTERS, 2018, 25 (09) : 1285 - 1289
  • [44] Classification of the Ambiguity of Frequency Determination in a Digital Receiver with Multirate Sub-Nyquist Sampling
    Podstrigaev, A. S.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2022, 67 (04) : 411 - 417
  • [45] Aliased Frequency Estimation by Using Two Coprime Sub-Nyquist Sampling Rates
    Zhang, Wenxu
    Cui, Xinlei
    Zhao, Zhongkai
    Lu, Manjun
    Zhao, Xiaoqi
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2024, 71 (03) : 1516 - 1520
  • [46] Fast High-resolution Imaging Method for Wideband Spinning Targets under Sub-Nyquist Sampling
    Xiang Hu
    Li Shaodong
    Xiang Long
    Chen Wenfeng
    Yang Jun
    JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2018, 40 (11) : 2630 - 2637
  • [47] A Sub-Nyquist Analog Front-End with Subarray Beamforming for Ultrasound Imaging
    Spaulding, Jonathon
    Eldar, Yonina C.
    Murmann, Boris
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [48] SUB-NYQUIST SAMPLING OF OFDM SIGNALS FOR COGNITIVE RADIOS
    Zahavy, Tom
    Shayer, Oran
    Cohen, Deborah
    Tolmachev, Alex
    Eldar, Yonina C.
    2014 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2014,
  • [49] Acquisition of Multiband Signals with Minimum Sub-Nyquist Sampling
    Munoz-Ferreras, Jose-Maria
    Gomez-Garcia, Roberto
    Perez-Martinez, Felix
    2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012, : 830 - 833
  • [50] Sub-Nyquist sampling for short pulses with Gabor frames
    Cheng Wang
    Ying Wang
    Peng Chen
    Chen Meng
    Xiangjun Song
    Wanling Li
    EURASIP Journal on Wireless Communications and Networking, 2017