Optimal cycle for plate heat exchanger cleaning in customer substation

被引:0
|
作者
Burd, AL
Burd, GS
机构
关键词
district heating; customer substation; domestic hot water and space heating systems; plate heat exchangers; fouling deposits; heat transfer;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Over the time a heating surface of a heat exchanger should be cleaned to remove fouling deposits. If this is not done regularly, the maintenance and operating costs are increased. Therefore, it is important to determine an optimal cycle for heat exchanger cleaning. Objectives of this paper are to assess an impact of deposits on heat exchanger plates, on changing their heating and hydraulic characteristics, on the amount of electric energy required to pump heating mediums through the heat exchanger, on the size of the heating surface and on the frequency of cleaning. In addition to that, a formation of fouling deposits on the heat exchanger in customer substation may lead to an increased heating medium now rate that is required from a district heating system. Developed mathematical model allows to evaluate different factors impacting heat exchanger performance and to determine an optimal period between two consecutive heat exchanger cleanings. The advantages of use of plate-and-frame heat exchangers in district heating system customer substations (for domestic hot water and space heating) as compared to shell-and-tube heat exchangers are also demonstrated.
引用
收藏
页码:177 / 192
页数:16
相关论文
共 50 条
  • [21] EXPERIENCES ENCOUNTERED IN AUTOMATED CLEANING OF AN ULTRA HIGH-TEMPERATURE PLATE HEAT EXCHANGER
    EVANS, DA
    WEST, EL
    LITSKY, W
    [J]. JOURNAL OF DAIRY SCIENCE, 1964, 47 (12) : 1458 - &
  • [22] An optimal plate fin heat exchanger for adsorption chilling: Theoretical consideration
    Grekova A.
    Tokarev M.
    [J]. International Journal of Thermofluids, 2022, 16
  • [23] More on heat exchanger cleaning methods
    Uhlman, RD
    [J]. MATERIALS PERFORMANCE, 2006, 45 (01) : 10 - 11
  • [24] Self-cleaning heat exchanger
    不详
    [J]. HYDROCARBON PROCESSING, 1998, 77 (09): : 35 - 35
  • [25] Optimize heat exchanger cleaning schedules
    O'Donnell, BR
    Barna, BA
    Gosling, CD
    [J]. CHEMICAL ENGINEERING PROGRESS, 2001, 97 (06) : 56 - 60
  • [26] CIRCULATION CLEANING OF A PLATE HEAT-EXCHANGER FOULED BY TOMATO JUICE .2. CLEANING WITH CAUSTIC SODA SOLUTION
    CHEOW, CS
    JACKSON, AT
    [J]. JOURNAL OF FOOD TECHNOLOGY, 1982, 17 (04): : 431 - 440
  • [27] The effect of plate spacing in plate heat exchanger design as a condenser in organic Rankine cycle for low temperature heat source
    Rohmah, Nur
    Pikra, Ghalya
    Purwanto, Andri Joko
    Pramana, Rakhmad Indra
    [J]. 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY ENGINEERING AND APPLICATION (ICSEEA) 2014 SUSTAINABLE ENERGY FOR GREEN MOBILITY, 2015, 68 : 87 - 96
  • [28] Online Integration of Optimal Cleaning Scheduling and Control of Heat Exchanger Networks under Fouling
    Santamaria, Federico Lozano
    Macchietto, Sandro
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (06) : 2471 - 2490
  • [29] Experimental investigation of performance of plate heat exchanger as organic Rankine cycle evaporator
    Jeong, Hoyoung
    Oh, Jinwoo
    Lee, Hoseong
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 159
  • [30] Effect of calcium content and flow regime on whey protein fouling and cleaning in a plate heat exchanger
    Khaldi, M.
    Blanpain-Avet, P.
    Guerin, R.
    Ronse, G.
    Bouvier, L.
    Andre, C.
    Bornaz, S.
    Croguennec, T.
    Jeantet, R.
    Delaplace, G.
    [J]. JOURNAL OF FOOD ENGINEERING, 2015, 147 : 68 - 78