Over the time a heating surface of a heat exchanger should be cleaned to remove fouling deposits. If this is not done regularly, the maintenance and operating costs are increased. Therefore, it is important to determine an optimal cycle for heat exchanger cleaning. Objectives of this paper are to assess an impact of deposits on heat exchanger plates, on changing their heating and hydraulic characteristics, on the amount of electric energy required to pump heating mediums through the heat exchanger, on the size of the heating surface and on the frequency of cleaning. In addition to that, a formation of fouling deposits on the heat exchanger in customer substation may lead to an increased heating medium now rate that is required from a district heating system. Developed mathematical model allows to evaluate different factors impacting heat exchanger performance and to determine an optimal period between two consecutive heat exchanger cleanings. The advantages of use of plate-and-frame heat exchangers in district heating system customer substations (for domestic hot water and space heating) as compared to shell-and-tube heat exchangers are also demonstrated.
引用
收藏
页码:177 / 192
页数:16
相关论文
共 50 条
  • [1] Optimal cleaning schedule for heat exchangers in a heat exchanger network
    Markowski, M
    Urbaniec, K
    [J]. APPLIED THERMAL ENGINEERING, 2005, 25 (07) : 1019 - 1032
  • [2] Optimal Cleaning Cycle Scheduling under Uncertain Conditions: A Flexibility Analysis on Heat Exchanger Fouling
    Di Pretoro, Alessandro
    D'Iglio, Francesco
    Manenti, Flavio
    [J]. PROCESSES, 2021, 9 (01) : 1 - 18
  • [3] Optimal design of a plate heat exchanger with undulated surfaces
    Kanaris, A. G.
    Mouza, A. A.
    Paras, S. V.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (06) : 1184 - 1195
  • [4] Experimental Study of Self-cleaning Plate Shell Heat Exchanger
    Zhou, Yangmin
    Li, Chao
    Xu, Lili
    Luo, Siyi
    Yi, Chuijie
    [J]. ADVANCED MANUFACTURING SYSTEMS, 2011, 339 : 176 - 179
  • [5] THE PARAMETERS OF CLEANING A CIP SYSTEM AFFECTED ENERGY CONSUMPTION AND CLEANING EFFICIENCY OF THE PLATE HEAT EXCHANGER
    Piepiorka-Stepuk, Joanna
    Diakun, Jaroslaw
    Jakubowski, Marek
    [J]. CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2017, 38 (01): : 111 - 120
  • [6] Optimal cyclic cleaning scheduling in heat exchanger networks under fouling
    Georgiadis, MC
    Papageorgiou, LG
    Macchietto, S
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 1999, 23 : S203 - S206
  • [7] Optimal energy and cleaning management in heat exchanger networks under fouling
    Georgiadis, MC
    Papageorgiou, LG
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A2): : 168 - 179
  • [8] Optimal cleaning policies in heat exchanger networks under rapid fouling
    Georgiadis, MC
    Papageorgiou, LG
    Macchietto, S
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2000, 39 (02) : 441 - 454
  • [9] Mitigation of fouling in refinery heat exchanger networks by optimal management of cleaning
    Smaili, F
    Vassiliadis, VS
    Wilson, DI
    [J]. ENERGY & FUELS, 2001, 15 (05) : 1038 - 1056
  • [10] A screening method for the optimal selection of plate heat exchanger configurations
    Pinto, JM
    Gut, JAW
    [J]. BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2002, 19 (04) : 433 - 439