Assessment of Regional Ventilation During Recruitment Maneuver by Electrical Impedance Tomography in Dogs

被引:8
|
作者
Ambrosio, Aline Magalhaes [1 ]
Sanchez, Ana Flavia [1 ]
Pereira, Marco Aurelio Amador [1 ]
De Andrade, Felipe Silveira Rego Monteiro [1 ]
Rodrigues, Renata Ramos [1 ]
Vitorasso, Renato de Lima [2 ]
Moriya, Henrique Takachi [2 ]
Fantoni, Denise Tabacchi [1 ]
机构
[1] Univ Sao Paulo, Sch Vet Med & Anim Sci, Dept Surg, Sao Paulo, Brazil
[2] Univ Sao Paulo, Biomed Engn Lab, Escola Politecn, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
protective mechanical ventilation; atelectasis; overdistention; low tidal volume; oxygenation; stretch; respiratory mechanics; END-EXPIRATORY-PRESSURE; RESPIRATORY SYSTEM COMPLIANCE; TIDAL-VOLUME VENTILATION; GAS-EXCHANGE; MECHANICAL VENTILATION; DRIVING PRESSURE; LUNG COMPLIANCE; ANESTHESIA; HORSES; OXYGEN;
D O I
10.3389/fvets.2021.815048
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundDuring protective mechanical ventilation, electrical impedance tomography (EIT) is used to monitor alveolar recruitment maneuvers as well as the distribution of regional ventilation. This technique can infer atelectasis and lung overdistention during mechanical ventilation in anesthetized patients or in the ICU. Changes in lung tissue stretching are evaluated by monitoring the electrical impedance of lung tissue with each respiratory cycle. ObjectiveThis study aimed to evaluate the distribution of regional ventilation during recruitment maneuvers based on the variables obtained in pulmonary electrical impedance tomography during protective mechanical ventilation, focusing on better lung recruitment associated with less or no overdistention. MethodsProspective clinical study using seven adult client-owned healthy dogs, weighing 25 +/- 6 kg, undergoing elective ovariohysterectomy or orchiectomy. The animals were anesthetized and ventilated in volume-controlled mode (7 ml.kg(-1)) with stepwise PEEP increases from 0 to 20 cmH(2)O in steps of 5 cmH(2)O every 5 min and then a stepwise decrease. EIT, respiratory mechanics, oxygenation, and hemodynamic variables were recorded for each PEEP step. ResultsThe results show that the regional compliance of the dependent lung significantly increased in the PEEP 10 cmH(2)O decrease step when compared with baseline (p < 0.027), and for the nondependent lung, there was a decrease in compliance at PEEP 20 cmH(2)O (p = 0.039) compared with baseline. A higher level of PEEP was associated with a significant increase in silent space of the nondependent regions from the PEEP 10 cmH(2)O increase step (p = 0.048) until the PEEP 15 cmH(2)O (0.019) decrease step with the highest values at PEEP 20 cmH(2)0 (p = 0.016), returning to baseline values thereafter. Silent space of the dependent regions did not show any significant changes. Drive pressure decreased significantly in the PEEP 10 and 5 cmH(2)O decrease steps (p = 0.032) accompanied by increased respiratory static compliance in the same PEEP step (p = 0.035 and 0.018, respectively). ConclusionsThe regional ventilation distribution assessed by EIT showed that the best PEEP value for recruitment maintenance, capable of decreasing areas of pulmonary atelectasis in dependent regions promoting less overinflation in nondependent areas, was from 10 to 5 cmH(2)O decreased steps.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation
    Frerichs, I.
    Schmitz, G.
    Pulletz, S.
    Schaedler, D.
    Zick, G.
    Scholz, J.
    Weiler, N.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S261 - S267
  • [12] Real-time assessment of global and regional lung ventilation in the anti-gravity straining maneuver using electrical impedance tomography
    Yang, Lin
    Dai, Meng
    Li, Shiqin
    Wang, Hang
    Cao, Xinsheng
    Zhao, Zhanqi
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 135
  • [13] Regional ventilation by electrical impedance tomography - A comparison with ventilation scintigraphy in pigs
    Hinz, J
    Neumann, P
    Dudykevych, T
    Andersson, LG
    Wrigge, H
    Burchardi, H
    Hedenstierna, G
    [J]. CHEST, 2003, 124 (01) : 314 - 322
  • [14] Electrical Impedance Tomography During Mechanical Ventilation
    Walsh, Brian K.
    Smallwood, Craig D.
    [J]. RESPIRATORY CARE, 2016, 61 (10) : 1417 - 1424
  • [15] Assessment of regional ventilation with the electrical impedance tomography in a patient after asphyxial cardiac arrest
    Dostal, Pavel
    Truhlar, Anatolij
    Polak, Josef
    Sedlak, Vratislav
    Turek, Zdenek
    [J]. RESUSCITATION, 2014, 85 (08) : E115 - E117
  • [16] Effect of PEEP on regional ventilation during laparoscopic surgery monitored by electrical impedance tomography
    Karsten, J.
    Luepschen, H.
    Grossherr, M.
    Bruch, H. -P.
    Leonhardt, S.
    Gehring, H.
    Meier, T.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (07) : 878 - 886
  • [17] Monitoring of regional lung ventilation using electrical impedance tomography
    Vasques, Francesco
    Sanderson, Barnaby
    Barrett, Nicholas A.
    Camporota, Luigi
    [J]. MINERVA ANESTESIOLOGICA, 2019, 85 (11) : 1231 - 1241
  • [18] Regional ventilation in cystic fibrosis measured by electrical impedance tomography
    Zhao, Zhanqi
    Fischer, Rainald
    Frerichs, Inez
    Mueller-Lisse, Ullrich
    Moeller, Knut
    [J]. JOURNAL OF CYSTIC FIBROSIS, 2012, 11 (05) : 412 - 418
  • [19] Regional ventilation of patients with hemidiaphragm paralysis by electrical impedance tomography
    Pereira, Mayra Caleffi
    Torsani, Vinicius
    Apanavicius, Andre
    Ferreira, Jeferson George
    Iamonti, Vinicius C.
    Passos Amato, Marcelo Britto
    Ribeiro de Carvalho, Carlos Roberto
    Pereira de Albuquerque, Andre Luis
    Caruso, Pedro
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [20] Estimation of regional lung volume changes by electrical impedance tomography during a pressure-volume maneuver
    Genderingen, HR
    Vught, AJ
    Jansen, JRC
    [J]. INTENSIVE CARE MEDICINE, 2003, 29 (02) : 233 - 240