Feasibility of a telemedicine framework for collaborative pacemaker follow-up

被引:9
|
作者
Kollmann, Alexander
Hayn, Dieter
Garcia, Jose
Trigo, Jesus Daniel
Kastner, Peter
Rotman, Brigitte
Tscheliessnigg, Karlheinz
Schreier, Guenter
机构
[1] Austrian Res Ctr GmbH ARC, Biomed Engn eHlth Syst, A-8020 Graz, Austria
[2] Med Univ Graz, Div Cardiol, Graz, Austria
[3] Med Univ Graz, Dept Transplantat, Div Surg, Graz, Austria
[4] Inst Invest Ingn Aragon, Zaragoza, Spain
关键词
D O I
10.1258/135763307782215316
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
We propose a telemedicine framework for remote and manufacturer independent pacemaker (PM) follow-up. The main goal is to provide the caregiver at the point-of-care with an efficient screening method to identify possible malfunction of the pacing system in collaboration with the specialist at the PM clinic. The concept was evaluated in a clinical trial on 44 patients (mean age 76 years). A total of 62 electrocardiogram (ECG) recordings were transmitted using a mobile PM follow-up unit. Using the automatic classification algorithm, 32 PMs were classified as 'OK' and eight PMs were classified as 'not OK'. In four cases a prediction regarding the working status of the PM was not possible. The signal processing classification was confirmed by expert classification (manual review of the ECG). The results indicate that the proposed PM follow-up concept has the potential to work as an efficient screening method and may spare a significant number of patients the burden of having to travel to specialized PM clinics.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [41] An initial experience with telemedicine in follow-up burn care
    Redlick, F
    Roston, B
    Gomez, M
    Fish, JS
    [J]. JOURNAL OF BURN CARE & REHABILITATION, 2002, 23 (02): : 110 - 115
  • [42] FOLLOW-UP OF A COHORT OF PACEMAKER PATIENTS 9 YEARS ON
    RIDDELL, F
    WHITLOCK, RML
    SMITH, W
    [J]. NEW ZEALAND MEDICAL JOURNAL, 1991, 104 (914) : 265 - 265
  • [43] ACCURACY AND CLINICAL UTILITY OF TRANSTELEPHONIC PACEMAKER FOLLOW-UP
    GESSMAN, LJ
    VIELBIG, RE
    WASPE, LE
    MOSS, L
    DAMM, D
    SUNDEEN, F
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (05): : 1032 - 1036
  • [44] HEMODYNAMIC MONITORING, CARDIAC OUTPUT, ON PACEMAKER FOLLOW-UP
    Gorini, D.
    Spitali, G.
    Tampieri, E.
    Placci, A.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S61 - S61
  • [45] IMPROVED PACEMAKER FOLLOW-UP MANAGEMENT WITH COMPUTERIZED SYSTEMS
    MOREIRA, LFP
    VELLOSO, VWB
    OLIVEIRA, Z
    COSTA, R
    STOLF, NAG
    JATENE, AD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 720 - 720
  • [46] Holter EKG for follow-up of pacemaker patients - a necessity?
    Nagel, B.
    Gamillscheg, A.
    Anelli-Monti, M.
    Beitzke, A.
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2007, 96 (09) : 664 - 664
  • [47] PERSONAL COMPUTERS IN PACEMAKER PATIENT TESTING AND FOLLOW-UP
    BERGELSON, M
    PARSONNET, V
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 645 - 645
  • [48] FOLLOW-UP OF A MINUTE VENTILATION RATE ADAPTIVE PACEMAKER
    LI, H
    NEUBAUER, SA
    HAYES, DL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 1826 - 1829
  • [49] AMBULATORY MONITORING SYSTEMS FOR PACEMAKER PATIENT FOLLOW-UP
    JIRAK, TL
    MOSS, AJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A82 - A82
  • [50] DEMAND TYPE PACEMAKER AND TELETRANSMITTER FOLLOW-UP SYSTEM
    STARR, A
    DABOLT, L
    DOBBS, JL
    PIERIE, W
    [J]. CIRCULATION, 1972, 46 (04) : 109 - &