Neutron diagnostics using nickel foil activation analysis in the KSTAR

被引:2
|
作者
Chae, San [1 ,2 ]
Lee, Jae-Yong [2 ]
Kim, Yong-Soo [2 ]
机构
[1] Korea Atom Energy Res Inst, 989-111 Daedeok Daero, Yuseong, Daejeon, South Korea
[2] Hanyang Univ, 222 Wangsimni Ro, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Neutron activation analysis; KSTAR; Neutron yield; Gamma spectroscopy; MCNP; YIELDS; JET;
D O I
10.1016/j.net.2021.03.021
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The spatial distribution and the energy spectrum of the neutron yield were investigated with the neutron activation analysis and MCNP simulation was carried out to verify the analysis results and to extend the results to a 3D mapping of the neutron yield distribution in the KSTAR. High purity Ni specimen was selected in the neutron activation analysis. Total neutron yields turned out to be 3.76 x 10(12) n/s - 7.56 x 10(12) n/s at the outer vessel of the KSTAR, two orders of magnitude lower than those at the inner vessel of the KSTAR, which demonstrates the attenuation of neutron yield while passing through the different structural materials of the reactor. Based on the fully expanded 3D simulation results, 2D cross-sectional distributions of the neutron yield on XY and ZX planes of KSTAR were examined. The results reveal that the neutron yield has its maximum concentration near the center of blanket and decreases with increasing proximity to the vacuum vessel wall. (C) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:3012 / 3017
页数:6
相关论文
共 50 条
  • [1] Initial result of neutron energy spectrum reconstruction using multi-foil activation method in KSTAR
    Jo, Jungmin
    Cheon, MunSeong
    Chung, Kyoung-Jae
    Hwang, Y. S.
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 793 - 796
  • [2] Triton burnup measurements in KSTAR using a neutron activation system
    Jo, Jungmin
    Cheon, MunSeong
    Kim, Jun Young
    Rhee, T.
    Kim, Junghee
    Shi, Yue-Jiang
    Isobe, M.
    Ogawa, K.
    Chung, Kyoung-Jae
    Hwang, Y. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [3] Diagnostic neutron activation system for KSTAR
    Cheon, M. S.
    Lee, Y. S.
    England, A. C.
    Kim, H. S.
    Pak, S.
    Seon, C. R.
    Lee, H. G.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [4] Measurements of Neutron Fields in a Wide Energy Range Using Multi-Foil Activation Analysis
    Chiesa, D.
    Cazzaniga, C.
    Nastasi, M.
    Rebai, M.
    Frost, C. D.
    Gorini, G.
    Lilley, S.
    Pozzi, S.
    Previtali, E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (07) : 1659 - 1666
  • [5] DETERMINATION OF NICKEL HYDROGENATED FATS BY NEUTRON ACTIVATION ANALYSIS
    SOULIOTIS, AG
    ANALYTICAL CHEMISTRY, 1964, 36 (07) : 1385 - &
  • [6] SUBSTOICHIOMETRIC DETERMINATION OF NICKEL BY NEUTRON-ACTIVATION ANALYSIS
    SHAH, PK
    HALDAR, BC
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1979, 39 (4-5): : 301 - 308
  • [7] Optimising Foil Selection for Neutron Activation Systems
    Wong, O.
    Smith, R.
    Nobs, C. R.
    Bruce, A. M.
    JOURNAL OF FUSION ENERGY, 2022, 41 (01)
  • [8] Optimising Foil Selection for Neutron Activation Systems
    O. Wong
    R. Smith
    C. R. Nobs
    A. M. Bruce
    Journal of Fusion Energy, 2022, 41
  • [9] Nickel Foil as Transmutation Detector for Neutron Fluence Measurements
    Klupak, Vit
    Viererbl, Ladislav
    Lahodova, Zdena
    Soltes, Jaroslav
    Tomandl, Ivo
    Kudejova, Petra
    ISRD 15 - INTERNATIONAL SYMPOSIUM ON REACTOR DOSIMETRY, 2016, 106
  • [10] Determination of trace impurities in nickel-based alloy using neutron activation analysis
    Zaidi, JH
    Waheed, S
    Ahmed, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (02) : 259 - 263