Thermodynamic Optimization of Advanced Organic Rankine Cycle Configurations for Geothermal Energy Applications

被引:4
|
作者
Mustapic, Nenad [1 ]
Brkic, Vladislav [2 ]
Duic, Zeljko [2 ]
Kralj, Toni [1 ]
机构
[1] Karlovac Univ Appl Sci, Trg Josipa Jurja Strossmayera 9, Karlovac 47000, Croatia
[2] Univ Zagreb, Fac Min Geol & Petr Engn, Pierottijeva 6, Zagreb 10000, Croatia
关键词
Organic Rankine Cycle; dual-pressure ORC; double stage serial-parallel ORC configuration; geothermal energy; WASTE HEAT-RECOVERY; WORKING FLUIDS; PERFORMANCE ANALYSES; ORC; SYSTEM; LAYOUTS; DESIGN;
D O I
10.3390/en15196990
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Organic Rankine Cycle (ORC) is commonly accepted as a viable technology to convert from low to medium temperature geothermal energy into electrical energy. In practice, the reference technology for converting geothermal energy to electricity is the subcritical simple ORC system. Over time, geothermal ORC plants with more complex configurations (architectures) have been developed. In the open literature, a large number of advanced architectures or configurations have been introduced. An analysis of the scientific literature indicates that there is some confusion regarding the terminology of certain advanced ORC system architectures. A new categorization of advanced configurations has been proposed, with a special emphasis on the application of geothermal energy. The basic division of advanced plant configurations is into dual-pressure and dual-stage ORC systems. In this study, the real potential of advanced ORC architectures or configurations to improve performance as compared with the simple ORC configuration was explored. The research was conducted for a wide range of geothermal heat source temperatures (from 120 degrees C to 180 degrees C) and working fluids. Net power output improvements as compared with the basic subcritical simple ORC (SORC) configuration were examined. The ability to produce net power with different ORC configurations depends on the magnitude of the geothermal fluid temperature and the type of working fluid. At a lower value of geothermal fluid temperature (120 degrees C), the most net power of 18.71 (kW/(kg/s)) was realized by the dual-pressure ORC (DP ORC configuration) with working fluid R1234yf, while the double stage serial-parallel ORC configuration with a low-temperature preheater in a high-temperature stage ORC (DS parHTS LTPH ORC) generated 18.51 (kW/(kg/s)) with the working fluid combination R1234yf/R1234yf. At 140 degrees C, three ORC configurations achieved similar net power values, namely the simple ORC configuration (SORC), the DP ORC configuration, and the DS parHTS LTPH ORC configuration, which generated 31.03 (kW/(kg/s)) with R1234yf, 31.07 (kW/(kg/s)) with R1234ze(E), and 30.96 (kW/(kg/s)) with R1234ze(E)/R1234yf, respectively. At higher values of geothermal fluid temperatures (160 degrees C and 180 degrees C) both the SORC and DP ORC configurations produced the highest net power values, namely 48.58 (kW/(kg/s)) with R1234ze(E), 67.23 (kW/(kg/s)) with isobutene for the SORC configuration, and 50.0 (kW/(kg/s)) with isobutane and 69.67 (kW/(kg/s)) with n-butane for the the DP ORC configuration.
引用
收藏
页数:36
相关论文
共 50 条
  • [31] Exergoeconomic Optimization of an Organic Rankine Cycle for Low-Temperature Geothermal Heat Sources
    Heberle, F.
    Bassermann, P.
    Preissinger, M.
    Brueggemann, D.
    [J]. INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2012, 15 (02) : 119 - 126
  • [32] Organic Rankine Cycle (ORC) in geothermal power plants
    Hijriawan, M.
    Pambudi, N. A.
    Biddinika, M. K.
    Wijayanto, D. S.
    Kuncoro, I. W.
    Rudiyanto, B.
    Wibowo, K. M.
    [J]. 4TH ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE, 2019, 2019, 1402
  • [33] Thermodynamic analysis and optimization of a solar organic Rankine cycle operating with stable output
    Yang, Jingze
    Li, Jian
    Yang, Zhen
    Duan, Yuanyuan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 187 : 459 - 471
  • [34] Thermodynamic optimization of organic Rankine cycle using two-stage evaporation
    Li, Tailu
    Wang, Qiulin
    Zhu, Jialing
    Hu, Kaiyong
    Fu, Wencheng
    [J]. RENEWABLE ENERGY, 2015, 75 : 654 - 664
  • [35] 3-E analysis and optimization of an organic rankine flash cycle integrated with a PEM fuel cell and geothermal energy
    Li, Zhixiong
    Khanmohammadi, Shoaib
    Khanmohammadi, Saber
    Al-Rashed, Abdullah A. A. A.
    Ahmadi, Pouria
    Afrand, Masoud
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (03) : 2168 - 2185
  • [36] Thermodynamic performance of new thermofluidic feed pumps for Organic Rankine Cycle applications
    Richardson, E. S.
    [J]. APPLIED ENERGY, 2016, 161 : 75 - 84
  • [37] Thermodynamic analysis of a simple Organic Rankine Cycle
    Javanshir, Alireza
    Sarunac, Nenad
    [J]. ENERGY, 2017, 118 : 85 - 96
  • [38] Thermodynamic analysis of Organic Rankine Cycle with Ejector
    Li, Xinguo
    Zhao, Cuicui
    Hu, Xiaochen
    [J]. ENERGY, 2012, 42 (01) : 342 - 349
  • [39] Multi-objective optimization and grey relational analysis on configurations of organic Rankine cycle
    Wang, Y. Z.
    Zhao, J.
    Wang, Y.
    An, Q. S.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 114 : 1355 - 1363
  • [40] A THERMODYNAMIC ANALYSIS OF A SOLAR ORGANIC RANKINE CYCLE
    McClintic, John
    Kistenmacher, David A.
    Anderson, Josh
    Demirer, Onur
    Berberoglu, Halil
    [J]. INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 223 - 232