Performance of a PET detector with a 256ch flat panel PS-PMT

被引:0
|
作者
Inadama, N [1 ]
Murayama, H [1 ]
Watanabe, M [1 ]
Omura, T [1 ]
Yamashita, T [1 ]
Kawai, H [1 ]
Umehara, T [1 ]
Kasahara, T [1 ]
Orita, N [1 ]
Tsuda, T [1 ]
机构
[1] Natl Inst Radiol Sci, Chiba 260, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 256ch flat panel position sensitive photomultiplier tube (FP-PMT) is a promising device for a PET detector because of its large opening area, 52mm x 52 mm, and small dead space. The useful area of the FP-PMT is 89% to the opening area so that the FP-PMT affords optical coupling with a 16 x 16 array of scintillation crystals having 3mm x 3 mm bottom area. Its 14.7 mm thickness will also ensure a compact volume and less weight for the PET apparatus. We evaluated performance by irradiating 511keV gamma ray onto GSO crystals coupled to a prototype of the FP-PMT. The resultant positioning image map assure its capability for crystal identification. In a series of measurements, we used a multilayer polymer mirrors for a reflector of the detector. It was cut or marked for folding in precise sizes using a CO2 gas laser. Making folds on the reflector by a laser contributed to easier assembly of the detector composed of many small crystal elements and may potentially be utilized in various shaped detectors.
引用
收藏
页码:939 / 943
页数:5
相关论文
共 50 条
  • [21] Improvement of a PET Detector Performance by Setting Reflectors in Parallel With PMT Face
    Inadama, Naoko
    Murayama, Hideo
    Nishikido, Fumihiko
    Ohi, Junichi
    Yamaya, Taiga
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (01) : 497 - 505
  • [22] Study of the slow-fast preamplifier input parameter's effects on output image for LYSO scintillator with PS-PMT based animal PET
    Rad, S. Z. Islami
    Zafarghandi, M. Shamsaei
    Peyvandi, R. Gholipour
    Maragheh, M. Ghannadi
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2014, 57 (04) : 488 - 492
  • [23] Study of the slow-fast preamplifier input parameter’s effects on output image for LYSO scintillator with PS-PMT based animal PET
    S. Z. Islami Rad
    M. Shamsaei Zafarghandi
    R. Gholipour Peyvandi
    M. Ghannadi Maragheh
    Instruments and Experimental Techniques, 2014, 57 : 488 - 492
  • [24] Performance testing of the flat panel detector in cardiovascular imaging
    Shi, Z
    MEDICAL PHYSICS, 2003, 30 (06) : 1424 - 1424
  • [25] Proximity focusing RICH with flat panel PMT (Hamamatsu H8500) as photon detector and aerogel radiator
    Pestotnik, R
    Adachi, I
    Fratina, S
    Iijima, T
    Ishibashi, R
    Kawai, H
    Korpar, S
    Krizan, P
    Ogava, S
    Matsumoto, T
    Saitoh, S
    Seki, T
    Staric, M
    Stanovnik, A
    Sumiyoshi, T
    Suzuki, K
    Tabata, T
    Uchida, Y
    Unno, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2): : 158 - 162
  • [26] Performance Comparison of SiPM and PMT Based Preclinical PET Systems with Same Detector Geometries
    Krizsan, A. K.
    Lajtos, I.
    Emri, M.
    Kis, S. A.
    Opposits, G.
    Hegyesi, G.
    Kalinka, G.
    Gal, J.
    Kiraly, B.
    Imrek, J.
    Valastyan, I.
    Molnar, J.
    Sanfilippo, D.
    Dahlbom, M.
    Balkay, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S360 - S360
  • [27] SPATIAL AND ENERGY RESOLUTIONS OF A HEXAGONAL ANIMAL PET SCANNER BASED ON LGSO CRYSTAL AND FLAT-PANEL PMT
    Lee, Chan Mi
    Hong, Seong Jong
    Yoon, Hyun Suk
    Ito, Mikiko
    Kwon, Sun Il
    Park, Sang Keun
    Lee, Dong Soo
    Sim, Kwang Souk
    Lee, Jae Sung
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (01) : 53 - 60
  • [28] Imaging performance of a direct digital flat-panel radiographic detector
    Kengyelics, SM
    Davies, AG
    Launders, JH
    Cowen, AR
    Richardson, DL
    Wilson, P
    RADIOLOGY, 1998, 209P : 358 - 358
  • [29] Diagnostic performance of a flat panel detector at low tube voltage in chest radiography
    Rapp-Bernhardt, U
    Bernhardt, TM
    Lenzen, H
    Diederich, S
    Papke, K
    Heindel, WL
    RADIOLOGY, 2002, 225 : 382 - 383
  • [30] Quantitative analysis of performance of selenium flat-panel detector for interventional mammography
    Debrie, A
    Polischuk, B
    Rougeot, H
    Hansroul, M
    Poliquin, É
    Caron, M
    Wong, K
    Shukri, Z
    Martin, JP
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 176 - 184